V. Mathieu, K. Fukui, Mami Mastukawa, M. Kawabe, F. Anagnostou, E. Soffer, G. Haiat
{"title":"利用微布里渊散射评估新形成骨组织的生物力学特性","authors":"V. Mathieu, K. Fukui, Mami Mastukawa, M. Kawabe, F. Anagnostou, E. Soffer, G. Haiat","doi":"10.1109/ULTSYM.2010.5935895","DOIUrl":null,"url":null,"abstract":"The assessment of implant stability in bone tissue remains difficult because remodelling phenomena in the vicinity of the implant are still poorly understood. The present multimodality study investigates the potentiality of micro-Brillouin scattering technique to differentiate mature and newly formed bone microscopic elastic properties following an approach coupled with histological analysis. Coin-shaped Ti-6Al-4V implants were placed in vivo in rabbit tibia. After seven weeks of implantation, bone samples were removed, embedded in methyl methacrylate and sliced into 190 µm thick sections. A micro-Brillouin scattering technique was used to measure ultrasonic velocities in 10 µm diameter regions located in mature and newly formed bone. The same section was then stained for histological analysis of the mineral content of the bone sample. The mean values of the ultrasonic velocities were equal to 4.98 10−3 m/s in newly formed bone tissue and 5.20 10−3 m/s in mature bone. ANOVA (p=0.029) tests revealed significant differences between the two groups of measurements. Histological observations showed a lower degree of mineralization in newly formed bone than in mature cortical bone. The higher ultrasonic velocity measured in newly formed bone tissue compared to mature bone might be explained by the higher mineral content in mature bone, which was confirmed by histology. The results demonstrate the feasibility of micro-Brillouin scattering measurements to investigate the elastic properties of newly formed bone tissue.","PeriodicalId":6437,"journal":{"name":"2010 IEEE International Ultrasonics Symposium","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2010-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Assessment of the biomechanical properties of newly formed bone tissue using micro-Brillouin scattering\",\"authors\":\"V. Mathieu, K. Fukui, Mami Mastukawa, M. Kawabe, F. Anagnostou, E. Soffer, G. Haiat\",\"doi\":\"10.1109/ULTSYM.2010.5935895\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The assessment of implant stability in bone tissue remains difficult because remodelling phenomena in the vicinity of the implant are still poorly understood. The present multimodality study investigates the potentiality of micro-Brillouin scattering technique to differentiate mature and newly formed bone microscopic elastic properties following an approach coupled with histological analysis. Coin-shaped Ti-6Al-4V implants were placed in vivo in rabbit tibia. After seven weeks of implantation, bone samples were removed, embedded in methyl methacrylate and sliced into 190 µm thick sections. A micro-Brillouin scattering technique was used to measure ultrasonic velocities in 10 µm diameter regions located in mature and newly formed bone. The same section was then stained for histological analysis of the mineral content of the bone sample. The mean values of the ultrasonic velocities were equal to 4.98 10−3 m/s in newly formed bone tissue and 5.20 10−3 m/s in mature bone. ANOVA (p=0.029) tests revealed significant differences between the two groups of measurements. Histological observations showed a lower degree of mineralization in newly formed bone than in mature cortical bone. The higher ultrasonic velocity measured in newly formed bone tissue compared to mature bone might be explained by the higher mineral content in mature bone, which was confirmed by histology. The results demonstrate the feasibility of micro-Brillouin scattering measurements to investigate the elastic properties of newly formed bone tissue.\",\"PeriodicalId\":6437,\"journal\":{\"name\":\"2010 IEEE International Ultrasonics Symposium\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-10-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE International Ultrasonics Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2010.5935895\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE International Ultrasonics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2010.5935895","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Assessment of the biomechanical properties of newly formed bone tissue using micro-Brillouin scattering
The assessment of implant stability in bone tissue remains difficult because remodelling phenomena in the vicinity of the implant are still poorly understood. The present multimodality study investigates the potentiality of micro-Brillouin scattering technique to differentiate mature and newly formed bone microscopic elastic properties following an approach coupled with histological analysis. Coin-shaped Ti-6Al-4V implants were placed in vivo in rabbit tibia. After seven weeks of implantation, bone samples were removed, embedded in methyl methacrylate and sliced into 190 µm thick sections. A micro-Brillouin scattering technique was used to measure ultrasonic velocities in 10 µm diameter regions located in mature and newly formed bone. The same section was then stained for histological analysis of the mineral content of the bone sample. The mean values of the ultrasonic velocities were equal to 4.98 10−3 m/s in newly formed bone tissue and 5.20 10−3 m/s in mature bone. ANOVA (p=0.029) tests revealed significant differences between the two groups of measurements. Histological observations showed a lower degree of mineralization in newly formed bone than in mature cortical bone. The higher ultrasonic velocity measured in newly formed bone tissue compared to mature bone might be explained by the higher mineral content in mature bone, which was confirmed by histology. The results demonstrate the feasibility of micro-Brillouin scattering measurements to investigate the elastic properties of newly formed bone tissue.