氯己定和异丙醇对玻璃纤维桩的即时和延迟粘结强度的影响

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Giornale Italiano di Endodonzia Pub Date : 2019-10-31 DOI:10.32067/GIE.2019.33.02.06
Ellizandra Anater Lecardelli, V. Poletto-Neto, F. G. Pappen, T. Pereira-Cenci, R. D. Morgental
{"title":"氯己定和异丙醇对玻璃纤维桩的即时和延迟粘结强度的影响","authors":"Ellizandra Anater Lecardelli, V. Poletto-Neto, F. G. Pappen, T. Pereira-Cenci, R. D. Morgental","doi":"10.32067/GIE.2019.33.02.06","DOIUrl":null,"url":null,"abstract":"Aim: To investigate the effects of dentinal treatment with chlorhexidine and isopropyl alcohol, alone or associated, on the bond strength and bond stability of glass fiber posts cemented with a self-adhesive resin cement. \nMaterials and Methods: Forty bovine teeth were endodontically treated and randomly distributed into four groups, according to the dentinal treatment after post space preparation: distilled water (Control); 2% chlorhexidine (CHX); isopropyl alcohol (ISO); 2% chlorhexidine + isopropyl alcohol (CHX+ISO). Glass fiber posts were cemented with a self-adhesive resin cement and after 24 h specimens were cut into six 1.5 mm-thick slices. One slice of each root third (i.e. apical, middle and coronal) was subjected to immediate push-out test and the other was stored in distilled water at 37 °C for six months for delayed push-out test. Bond strength was registered in megapascal (MPa). Failure mode was evaluated by a stereomicroscope, with 40x magnification. Data analysis was performed using Kruskal-Wallis and Friedman tests, with 5% significance level. Results: No significant differences were detected between experimental groups or between root thirds in the same group in the immediate evaluation. After six months of aging, all groups showed a significant decrease in bond strength values, but ISO group presented higher bond strength than Control and CHX groups (p=0.0001). The most common type of failure for all groups was adhesive between resin cement and root dentine. \nConclusions: Dentinal treatment with CHX and ISO, isolated or combined, did not affect the immediate bond strength of glass fiber posts, but the ISO group presented better bond stability after six-month aging.","PeriodicalId":42221,"journal":{"name":"Giornale Italiano di Endodonzia","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2019-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Effect of chlorhexidine and isopropyl alcohol on immediate and delayed bond strength of glass fiber posts\",\"authors\":\"Ellizandra Anater Lecardelli, V. Poletto-Neto, F. G. Pappen, T. Pereira-Cenci, R. D. Morgental\",\"doi\":\"10.32067/GIE.2019.33.02.06\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim: To investigate the effects of dentinal treatment with chlorhexidine and isopropyl alcohol, alone or associated, on the bond strength and bond stability of glass fiber posts cemented with a self-adhesive resin cement. \\nMaterials and Methods: Forty bovine teeth were endodontically treated and randomly distributed into four groups, according to the dentinal treatment after post space preparation: distilled water (Control); 2% chlorhexidine (CHX); isopropyl alcohol (ISO); 2% chlorhexidine + isopropyl alcohol (CHX+ISO). Glass fiber posts were cemented with a self-adhesive resin cement and after 24 h specimens were cut into six 1.5 mm-thick slices. One slice of each root third (i.e. apical, middle and coronal) was subjected to immediate push-out test and the other was stored in distilled water at 37 °C for six months for delayed push-out test. Bond strength was registered in megapascal (MPa). Failure mode was evaluated by a stereomicroscope, with 40x magnification. Data analysis was performed using Kruskal-Wallis and Friedman tests, with 5% significance level. Results: No significant differences were detected between experimental groups or between root thirds in the same group in the immediate evaluation. After six months of aging, all groups showed a significant decrease in bond strength values, but ISO group presented higher bond strength than Control and CHX groups (p=0.0001). The most common type of failure for all groups was adhesive between resin cement and root dentine. \\nConclusions: Dentinal treatment with CHX and ISO, isolated or combined, did not affect the immediate bond strength of glass fiber posts, but the ISO group presented better bond stability after six-month aging.\",\"PeriodicalId\":42221,\"journal\":{\"name\":\"Giornale Italiano di Endodonzia\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2019-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Giornale Italiano di Endodonzia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32067/GIE.2019.33.02.06\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Giornale Italiano di Endodonzia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32067/GIE.2019.33.02.06","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

摘要

目的:探讨氯己定和异丙醇单独或联合治疗对自粘树脂水泥固接玻璃纤维桩的粘结强度和粘结稳定性的影响。材料与方法:对40颗牛牙进行根管治疗,根据牙槽位准备后的处理情况随机分为4组:蒸馏水组(对照组);2%氯己定(CHX);异丙醇;2%氯己定+异丙醇(CHX+ISO)。玻璃纤维桩用自粘树脂水泥胶结,24h后将试件切成6片1.5 mm厚的薄片。每三分之一根(即根尖、中间和冠状)的一片进行立即推出试验,另一片在37°C蒸馏水中保存6个月进行延迟推出试验。粘结强度单位为兆帕斯卡(MPa)。通过40倍放大的体视显微镜评估失效模式。数据分析采用Kruskal-Wallis和Friedman检验,显著性水平为5%。结果:实验组间、同一组三分根间即刻评价无显著差异。陈化6个月后,各组结合力值均显著降低,但ISO组结合力值高于对照组和CHX组(p=0.0001)。所有组中最常见的失败类型是树脂水泥与牙根本质之间的粘接。结论:CHX与ISO单独或联合处理牙本质均不影响玻璃纤维桩的即时粘结强度,但ISO组在6个月老化后具有更好的粘结稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of chlorhexidine and isopropyl alcohol on immediate and delayed bond strength of glass fiber posts
Aim: To investigate the effects of dentinal treatment with chlorhexidine and isopropyl alcohol, alone or associated, on the bond strength and bond stability of glass fiber posts cemented with a self-adhesive resin cement. Materials and Methods: Forty bovine teeth were endodontically treated and randomly distributed into four groups, according to the dentinal treatment after post space preparation: distilled water (Control); 2% chlorhexidine (CHX); isopropyl alcohol (ISO); 2% chlorhexidine + isopropyl alcohol (CHX+ISO). Glass fiber posts were cemented with a self-adhesive resin cement and after 24 h specimens were cut into six 1.5 mm-thick slices. One slice of each root third (i.e. apical, middle and coronal) was subjected to immediate push-out test and the other was stored in distilled water at 37 °C for six months for delayed push-out test. Bond strength was registered in megapascal (MPa). Failure mode was evaluated by a stereomicroscope, with 40x magnification. Data analysis was performed using Kruskal-Wallis and Friedman tests, with 5% significance level. Results: No significant differences were detected between experimental groups or between root thirds in the same group in the immediate evaluation. After six months of aging, all groups showed a significant decrease in bond strength values, but ISO group presented higher bond strength than Control and CHX groups (p=0.0001). The most common type of failure for all groups was adhesive between resin cement and root dentine. Conclusions: Dentinal treatment with CHX and ISO, isolated or combined, did not affect the immediate bond strength of glass fiber posts, but the ISO group presented better bond stability after six-month aging.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Giornale Italiano di Endodonzia
Giornale Italiano di Endodonzia DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
0.90
自引率
25.00%
发文量
0
审稿时长
24 weeks
期刊介绍: The Giornale Italiano di Endodonzia was founded in 1987 and is the official journal of the Italian Society of Endodontics (SIE). It is a peer-reviewed journal publishing original articles on clinical research and/or clinical methodology, case reports related to Endodontics. The Journal evaluates also contributes in restorative dentistry, dental traumatology, experimental pathophysiology, pharmacology and microbiology dealing with Endodontics.
期刊最新文献
Comparative efficacy of Depotphoresis and diode laser for reduction of microbial load and postoperative pain, and healing of periapical lesions: a randomized clinical trial Endodontics: clinical protocols on scientific basis Anatomical proximity of upper teeth and local factors associated with the thickness of the maxillary sinus membrane: a retrospective study A contemporary approach to treat necrotic immature teeth using different bioceramic materials Endodontic guides and ultrasonic tips for management of calcifications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1