F. Uba, E. O. Essandoh, G. Akolgo, Richard Opoku, Lawrence Oppong-Kyereh, Eric Gyimah
{"title":"非定常潮湿室外条件下无玻璃太阳能板传热系数的实验估算","authors":"F. Uba, E. O. Essandoh, G. Akolgo, Richard Opoku, Lawrence Oppong-Kyereh, Eric Gyimah","doi":"10.1155/2021/5522882","DOIUrl":null,"url":null,"abstract":"This research presents a study on the heat transfer coefficient for an unglazed solar plate collector in an unsteady humid outdoor environment. The purpose for undertaking this research is to investigate the correlation between the heat transfer coefficient and air speed and also verify whether heat transfer from unglazed solar thermal collectors under outdoor conditions can be experimentally determined using a particular mathematical relationship for different locations. In estimating the heat transfer coefficient for an unglazed solar plate in an unsteady humid outdoor condition, an experiment was held using an outdoor setup that measured temperatures, wind speeds, and solar radiations from 11:00 A.M. to 2:00 P.M. The solar plate collector was placed on a flat bed of height 2.2 m and a collection area of 0743 m2. An average temperature of 45°C was recorded for a mild steel plate collector which was initially exposed to an ambient temperature which ranges from 25°C to 32°C. The interfacial temperature between the plate and an asbestos board ranges from 42°C to 52°C, and that of the asbestos and a plywood is 40°C to 46°C. The specific heat capacity of the mild steel plate and the asbestos board used for the construction of the experimental setup are 25.00 kJ/kg and 950.00 kJ/kg, respectively, while the thermal conductivity of these materials is 0.46 W/m·K and 0.25 W/m·K, respectively. The novelty of this work is the use of such a study to generate empirical equations for Ghana and to produce representative equations for determining the heat transfer coefficient for solar plate collectors in unsteady humid outdoor conditions in West Africa. This work is expected to contribute data alongside similar works done for different areas to help propose empirical equations for estimating global and not site-specific heat transfer coefficients.","PeriodicalId":45541,"journal":{"name":"Modelling and Simulation in Engineering","volume":"15 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2021-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental Estimation of the Heat Transfer Coefficient of an Unglazed Solar Plate for Unsteady Humid Outdoor Condition\",\"authors\":\"F. Uba, E. O. Essandoh, G. Akolgo, Richard Opoku, Lawrence Oppong-Kyereh, Eric Gyimah\",\"doi\":\"10.1155/2021/5522882\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research presents a study on the heat transfer coefficient for an unglazed solar plate collector in an unsteady humid outdoor environment. The purpose for undertaking this research is to investigate the correlation between the heat transfer coefficient and air speed and also verify whether heat transfer from unglazed solar thermal collectors under outdoor conditions can be experimentally determined using a particular mathematical relationship for different locations. In estimating the heat transfer coefficient for an unglazed solar plate in an unsteady humid outdoor condition, an experiment was held using an outdoor setup that measured temperatures, wind speeds, and solar radiations from 11:00 A.M. to 2:00 P.M. The solar plate collector was placed on a flat bed of height 2.2 m and a collection area of 0743 m2. An average temperature of 45°C was recorded for a mild steel plate collector which was initially exposed to an ambient temperature which ranges from 25°C to 32°C. The interfacial temperature between the plate and an asbestos board ranges from 42°C to 52°C, and that of the asbestos and a plywood is 40°C to 46°C. The specific heat capacity of the mild steel plate and the asbestos board used for the construction of the experimental setup are 25.00 kJ/kg and 950.00 kJ/kg, respectively, while the thermal conductivity of these materials is 0.46 W/m·K and 0.25 W/m·K, respectively. The novelty of this work is the use of such a study to generate empirical equations for Ghana and to produce representative equations for determining the heat transfer coefficient for solar plate collectors in unsteady humid outdoor conditions in West Africa. This work is expected to contribute data alongside similar works done for different areas to help propose empirical equations for estimating global and not site-specific heat transfer coefficients.\",\"PeriodicalId\":45541,\"journal\":{\"name\":\"Modelling and Simulation in Engineering\",\"volume\":\"15 1\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2021-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Modelling and Simulation in Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2021/5522882\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Modelling and Simulation in Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2021/5522882","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
Experimental Estimation of the Heat Transfer Coefficient of an Unglazed Solar Plate for Unsteady Humid Outdoor Condition
This research presents a study on the heat transfer coefficient for an unglazed solar plate collector in an unsteady humid outdoor environment. The purpose for undertaking this research is to investigate the correlation between the heat transfer coefficient and air speed and also verify whether heat transfer from unglazed solar thermal collectors under outdoor conditions can be experimentally determined using a particular mathematical relationship for different locations. In estimating the heat transfer coefficient for an unglazed solar plate in an unsteady humid outdoor condition, an experiment was held using an outdoor setup that measured temperatures, wind speeds, and solar radiations from 11:00 A.M. to 2:00 P.M. The solar plate collector was placed on a flat bed of height 2.2 m and a collection area of 0743 m2. An average temperature of 45°C was recorded for a mild steel plate collector which was initially exposed to an ambient temperature which ranges from 25°C to 32°C. The interfacial temperature between the plate and an asbestos board ranges from 42°C to 52°C, and that of the asbestos and a plywood is 40°C to 46°C. The specific heat capacity of the mild steel plate and the asbestos board used for the construction of the experimental setup are 25.00 kJ/kg and 950.00 kJ/kg, respectively, while the thermal conductivity of these materials is 0.46 W/m·K and 0.25 W/m·K, respectively. The novelty of this work is the use of such a study to generate empirical equations for Ghana and to produce representative equations for determining the heat transfer coefficient for solar plate collectors in unsteady humid outdoor conditions in West Africa. This work is expected to contribute data alongside similar works done for different areas to help propose empirical equations for estimating global and not site-specific heat transfer coefficients.
期刊介绍:
Modelling and Simulation in Engineering aims at providing a forum for the discussion of formalisms, methodologies and simulation tools that are intended to support the new, broader interpretation of Engineering. Competitive pressures of Global Economy have had a profound effect on the manufacturing in Europe, Japan and the USA with much of the production being outsourced. In this context the traditional interpretation of engineering profession linked to the actual manufacturing needs to be broadened to include the integration of outsourced components and the consideration of logistic, economical and human factors in the design of engineering products and services.