{"title":"钻井液磁性含量的测量与分析","authors":"Pouyan Khalili, A. Saasen, M. Khalifeh, B. Aase, G. O. Ånesbug","doi":"10.2118/207240-ms","DOIUrl":null,"url":null,"abstract":"\n Magnetic contamination of drilling fluid can impact the accuracy of a directional survey by shielding the magnetic field. Additionally, this contamination, such as swarf or finer magnetic particles, can agglomerate on the downhole tool or BOP and cause tool failure in the worst-case scenario. Thus, it is necessary to measure the magnetic content of drilling fluid. However, there is no recommended practice in API or ISO for this purpose. A simple experimental setup and measurement system was developed that can be easily deployed in the rig site to measure the magnetic contamination of drilling fluid.\n 47 drilling fluid samples were collected from a multilateral production well drilled with a semi-submersible drilling rig located in one of the North Sea's fields. The magnetic content of these samples was measured using the established method, and the microstructure of the collected content was analyzed using a scanning electron microscope (SEM) and x-ray diffraction analysis (XRD).\n Ditch magnets are commonly installed in the flowline on the rig to remove the swarf and finer magnetic particles, if the design is optimized. Ditch magnet measurement data of the well that the drilling fluid samples were collected from is presented. Operational details and common factors that might increase the production of the magnetic content were also investigated. By comparing the measured magnetic contamination of the drilling fluid samples and ditch magnet measurement data, it was possible to evaluate the efficiency of the ditch magnet system.","PeriodicalId":10959,"journal":{"name":"Day 3 Wed, November 17, 2021","volume":"56 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measuring and Analyzing the Magnetic Content of Drilling Fluid\",\"authors\":\"Pouyan Khalili, A. Saasen, M. Khalifeh, B. Aase, G. O. Ånesbug\",\"doi\":\"10.2118/207240-ms\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Magnetic contamination of drilling fluid can impact the accuracy of a directional survey by shielding the magnetic field. Additionally, this contamination, such as swarf or finer magnetic particles, can agglomerate on the downhole tool or BOP and cause tool failure in the worst-case scenario. Thus, it is necessary to measure the magnetic content of drilling fluid. However, there is no recommended practice in API or ISO for this purpose. A simple experimental setup and measurement system was developed that can be easily deployed in the rig site to measure the magnetic contamination of drilling fluid.\\n 47 drilling fluid samples were collected from a multilateral production well drilled with a semi-submersible drilling rig located in one of the North Sea's fields. The magnetic content of these samples was measured using the established method, and the microstructure of the collected content was analyzed using a scanning electron microscope (SEM) and x-ray diffraction analysis (XRD).\\n Ditch magnets are commonly installed in the flowline on the rig to remove the swarf and finer magnetic particles, if the design is optimized. Ditch magnet measurement data of the well that the drilling fluid samples were collected from is presented. Operational details and common factors that might increase the production of the magnetic content were also investigated. By comparing the measured magnetic contamination of the drilling fluid samples and ditch magnet measurement data, it was possible to evaluate the efficiency of the ditch magnet system.\",\"PeriodicalId\":10959,\"journal\":{\"name\":\"Day 3 Wed, November 17, 2021\",\"volume\":\"56 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Day 3 Wed, November 17, 2021\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2118/207240-ms\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 3 Wed, November 17, 2021","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2118/207240-ms","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

钻井液的磁性污染会屏蔽磁场,从而影响定向测量的准确性。此外,这种污染,如碎屑或更细的磁性颗粒,可能会聚集在井下工具或防喷器上,在最坏的情况下导致工具失效。因此,有必要测量钻井液的磁性含量。然而,在API或ISO中没有针对此目的的推荐实践。开发了一种简单的实验装置和测量系统,可以方便地部署在钻井现场,以测量钻井液的磁性污染。在北海某油田的半潜式钻井平台上,从一口多边生产井中收集了47个钻井液样本。采用建立的方法测定了样品的磁性含量,并利用扫描电子显微镜(SEM)和x射线衍射仪(XRD)分析了样品的微观结构。如果设计优化,沟槽磁铁通常安装在钻机的流水线上,以去除屑和更细的磁性颗粒。介绍了钻井液样品采集井的沟磁测量数据。还研究了可能增加磁性含量产生的操作细节和常见因素。通过对比钻井液样品的磁性污染实测数据和沟磁测量数据,可以对沟磁系统的效率进行评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measuring and Analyzing the Magnetic Content of Drilling Fluid
Magnetic contamination of drilling fluid can impact the accuracy of a directional survey by shielding the magnetic field. Additionally, this contamination, such as swarf or finer magnetic particles, can agglomerate on the downhole tool or BOP and cause tool failure in the worst-case scenario. Thus, it is necessary to measure the magnetic content of drilling fluid. However, there is no recommended practice in API or ISO for this purpose. A simple experimental setup and measurement system was developed that can be easily deployed in the rig site to measure the magnetic contamination of drilling fluid. 47 drilling fluid samples were collected from a multilateral production well drilled with a semi-submersible drilling rig located in one of the North Sea's fields. The magnetic content of these samples was measured using the established method, and the microstructure of the collected content was analyzed using a scanning electron microscope (SEM) and x-ray diffraction analysis (XRD). Ditch magnets are commonly installed in the flowline on the rig to remove the swarf and finer magnetic particles, if the design is optimized. Ditch magnet measurement data of the well that the drilling fluid samples were collected from is presented. Operational details and common factors that might increase the production of the magnetic content were also investigated. By comparing the measured magnetic contamination of the drilling fluid samples and ditch magnet measurement data, it was possible to evaluate the efficiency of the ditch magnet system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Assessment of Unconventional Resources Opportunities in the Middle East Tethyan Petroleum System in a Transfer Learning Context Block 61 Drilling Fluids Optimization Journey High Resolution Reservoir Simulator Driven Custom Scripts as the Enabler for Solving Reservoir to Surface Network Coupling Challenges Pre-Engineered Standardized Turbomachinery Solutions: A Strategic Approach to Lean Project Management Using Active and Passive Near-Field Hydrophones to Image the Near-Surface in Ultra-Shallow Waters Offshore Abu Dhabi
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1