{"title":"一种新型多中心膝关节的运动学和动力学评估用于助力步行外骨骼","authors":"Émélie Séguin, Marc Doumit","doi":"10.33696/rehabilitation.5.034","DOIUrl":null,"url":null,"abstract":"Loss of mobility and independence directly affects the quality of life of many vulnerable individuals. In order to address this, researchers have been developing wearable walking assist exoskeletons to aid users with their daily activities. While this technology has advanced tremendously in the past decade, current exoskeletons are yet to be ergonomic, causing discomfort and injuries to the user, leading to early device rejection. This research intends to assess the kinematic and kinetic compatibility of a novel knee joint suitable for exoskeletons. The proposed knee design can be adapted to accommodate a kinematic offset and optimize force delivery. This is achieved by ensuring that the mechanical and biological joint rotation axes are aligned and that the moment arm can be varied to mimic the mechanical characteristics of a biological knee. Model simulations and mechanical testing of fabricated prototypes were achieved to analyze and validate the design. Results confirmed the compatibility of the design, which demonstrated kinematic absolute error values of 1.68 and 0.32 mm for the offset and aligned joints, respectively. It was shown that the moment arm can be varied throughout flexion, allowing future iterations to achieve optimal and effective moment transfer.","PeriodicalId":56043,"journal":{"name":"Turkish Journal of Physical Medicine and Rehabilitation","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Kinematic and Kinetic Assessment of a Novel Polycentric Knee Joint for Powered Walking Assist Exoskeletons\",\"authors\":\"Émélie Séguin, Marc Doumit\",\"doi\":\"10.33696/rehabilitation.5.034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Loss of mobility and independence directly affects the quality of life of many vulnerable individuals. In order to address this, researchers have been developing wearable walking assist exoskeletons to aid users with their daily activities. While this technology has advanced tremendously in the past decade, current exoskeletons are yet to be ergonomic, causing discomfort and injuries to the user, leading to early device rejection. This research intends to assess the kinematic and kinetic compatibility of a novel knee joint suitable for exoskeletons. The proposed knee design can be adapted to accommodate a kinematic offset and optimize force delivery. This is achieved by ensuring that the mechanical and biological joint rotation axes are aligned and that the moment arm can be varied to mimic the mechanical characteristics of a biological knee. Model simulations and mechanical testing of fabricated prototypes were achieved to analyze and validate the design. Results confirmed the compatibility of the design, which demonstrated kinematic absolute error values of 1.68 and 0.32 mm for the offset and aligned joints, respectively. It was shown that the moment arm can be varied throughout flexion, allowing future iterations to achieve optimal and effective moment transfer.\",\"PeriodicalId\":56043,\"journal\":{\"name\":\"Turkish Journal of Physical Medicine and Rehabilitation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-07-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkish Journal of Physical Medicine and Rehabilitation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.33696/rehabilitation.5.034\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Physical Medicine and Rehabilitation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.33696/rehabilitation.5.034","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 1

摘要

丧失行动能力和独立性直接影响到许多弱势群体的生活质量。为了解决这个问题,研究人员一直在开发可穿戴行走辅助外骨骼,以帮助用户进行日常活动。虽然这项技术在过去十年中取得了巨大的进步,但目前的外骨骼仍不符合人体工程学,给用户带来不适和伤害,导致早期设备被拒绝。本研究旨在评估一种适合外骨骼的新型膝关节的运动学和动力学相容性。所提出的膝关节设计可以适应运动学偏移和优化力传递。这是通过确保机械和生物关节旋转轴对齐来实现的,并且力矩臂可以改变以模仿生物膝关节的机械特性。通过模型仿真和制造样机的力学试验,对设计进行了分析和验证。结果证实了设计的兼容性,偏移关节和对齐关节的运动绝对误差分别为1.68和0.32 mm。结果表明,在整个弯曲过程中,力臂可以变化,允许未来的迭代实现最优和有效的力矩传递。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Kinematic and Kinetic Assessment of a Novel Polycentric Knee Joint for Powered Walking Assist Exoskeletons
Loss of mobility and independence directly affects the quality of life of many vulnerable individuals. In order to address this, researchers have been developing wearable walking assist exoskeletons to aid users with their daily activities. While this technology has advanced tremendously in the past decade, current exoskeletons are yet to be ergonomic, causing discomfort and injuries to the user, leading to early device rejection. This research intends to assess the kinematic and kinetic compatibility of a novel knee joint suitable for exoskeletons. The proposed knee design can be adapted to accommodate a kinematic offset and optimize force delivery. This is achieved by ensuring that the mechanical and biological joint rotation axes are aligned and that the moment arm can be varied to mimic the mechanical characteristics of a biological knee. Model simulations and mechanical testing of fabricated prototypes were achieved to analyze and validate the design. Results confirmed the compatibility of the design, which demonstrated kinematic absolute error values of 1.68 and 0.32 mm for the offset and aligned joints, respectively. It was shown that the moment arm can be varied throughout flexion, allowing future iterations to achieve optimal and effective moment transfer.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Turkish Journal of Physical Medicine and Rehabilitation
Turkish Journal of Physical Medicine and Rehabilitation Health Professions-Physical Therapy, Sports Therapy and Rehabilitation
CiteScore
2.20
自引率
0.00%
发文量
0
期刊介绍: The Turkish Journal of Physical Medicine and Rehabilitation (Formerly published as Türkiye Fiziksel Tıp ve Rehabilitasyon Dergisi) is the official journal of the Turkish Society of Physical Medicine and Rehabilitation. The journal is an international open-access, double-blind peer-reviewed periodical journal bringing the latest developments in all aspects of physical medicine and rehabilitation, and related fields. The journal publishes original articles, review articles, editorials, case reports (limited), letters to the editors. The target readership includes academic members, specialists, residents working in the fields of Physical Medicine and Rehabilitation. The language of the journal is English and it is published quarterly (in March, June, September, and December).
期刊最新文献
Comprehensive analysis of publication of physical medicine and rehabilitation theses in Türkiye between years 2010 and 2020: Academic productivity and related factors. Effect of platelet-rich plasma injections versus placebo on pain and quality of life in patients with hip osteoarthritis: A double-blind, randomized clinical trial. Local ozone injection compared to local glucocorticoid injection in carpal tunnel syndrome: A randomized controlled trial. Which aerobic exercise is more effective in Parkinson's patients? Cycle ergometer versus body weight-supported treadmill. Adherence to complete decongestive therapy in patients with postmastectomy lymphedema and related factors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1