{"title":"变密度z谱采集方案在MR化学交换饱和转移效应量化中的性能研究。","authors":"Shasha Yang, Yin Wu","doi":"10.1109/EMBC.2015.7320231","DOIUrl":null,"url":null,"abstract":"Chemical exchange saturation transfer (CEST) MRI emerges as a powerful imaging method to probe chemical exchange between bulk water and labile protons. Conventional CEST imaging needs detailed Z-spectrum acquisition, even at frequencies with limited information for CEST parameter quantification, which harms imaging efficiency and is not favorable in practical applications. In this study, a variable-density Z-spectrum acquisition scheme was proposed. Data with saturation frequencies close to water, labile protons and their negative frequency offset was densely sampled, while the remaining part was sparsely acquired. The accuracy of the proposed method in CEST ratio measurement was investigated with numerical simulation. Compared to the conventionally evenly distributed Z-spectrum acquisition method, the proposed scheme showed significant improvement of CEST ratio characterization with existence of noise and static magnetic field inhomogeneity. With the additional advantage of easy implementation, the developed Z-spectrum acquisition scheme provides a useful framework for accurate CEST parameter quantification without compromising the imaging time.","PeriodicalId":72689,"journal":{"name":"Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference","volume":"14 1","pages":"7929-32"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of the performance of variable-density Z-spectrum acquisition scheme in MR chemical exchange saturation transfer effect quantification.\",\"authors\":\"Shasha Yang, Yin Wu\",\"doi\":\"10.1109/EMBC.2015.7320231\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Chemical exchange saturation transfer (CEST) MRI emerges as a powerful imaging method to probe chemical exchange between bulk water and labile protons. Conventional CEST imaging needs detailed Z-spectrum acquisition, even at frequencies with limited information for CEST parameter quantification, which harms imaging efficiency and is not favorable in practical applications. In this study, a variable-density Z-spectrum acquisition scheme was proposed. Data with saturation frequencies close to water, labile protons and their negative frequency offset was densely sampled, while the remaining part was sparsely acquired. The accuracy of the proposed method in CEST ratio measurement was investigated with numerical simulation. Compared to the conventionally evenly distributed Z-spectrum acquisition method, the proposed scheme showed significant improvement of CEST ratio characterization with existence of noise and static magnetic field inhomogeneity. With the additional advantage of easy implementation, the developed Z-spectrum acquisition scheme provides a useful framework for accurate CEST parameter quantification without compromising the imaging time.\",\"PeriodicalId\":72689,\"journal\":{\"name\":\"Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference\",\"volume\":\"14 1\",\"pages\":\"7929-32\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMBC.2015.7320231\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMBC.2015.7320231","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

化学交换饱和转移核磁共振成像(CEST)是一种探测散装水与不稳定质子之间化学交换的强大成像方法。传统的CEST成像需要详细的z谱采集,即使是在信息有限的频率下进行CEST参数量化,也会影响成像效率,不利于实际应用。本文提出了一种变密度z谱采集方案。饱和频率接近水、不稳定质子及其负频率偏移的数据被密集采样,而其余部分则被稀疏获取。通过数值模拟研究了该方法在CEST比测量中的精度。与传统的均匀分布的z谱采集方法相比,该方案在存在噪声和静磁场不均匀性的情况下显著改善了CEST比表征。由于易于实现的额外优势,开发的z谱采集方案为准确的CEST参数量化提供了有用的框架,而不会影响成像时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Investigation of the performance of variable-density Z-spectrum acquisition scheme in MR chemical exchange saturation transfer effect quantification.
Chemical exchange saturation transfer (CEST) MRI emerges as a powerful imaging method to probe chemical exchange between bulk water and labile protons. Conventional CEST imaging needs detailed Z-spectrum acquisition, even at frequencies with limited information for CEST parameter quantification, which harms imaging efficiency and is not favorable in practical applications. In this study, a variable-density Z-spectrum acquisition scheme was proposed. Data with saturation frequencies close to water, labile protons and their negative frequency offset was densely sampled, while the remaining part was sparsely acquired. The accuracy of the proposed method in CEST ratio measurement was investigated with numerical simulation. Compared to the conventionally evenly distributed Z-spectrum acquisition method, the proposed scheme showed significant improvement of CEST ratio characterization with existence of noise and static magnetic field inhomogeneity. With the additional advantage of easy implementation, the developed Z-spectrum acquisition scheme provides a useful framework for accurate CEST parameter quantification without compromising the imaging time.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.20
自引率
0.00%
发文量
0
期刊最新文献
Rapid Label-free DNA Quantification by Multi-frequency Impedance Sensing on a Chip. A Comparison of 1-D and 2-D Deep Convolutional Neural Networks in ECG Classification Brain Morphometry Analysis with Surface Foliation Theory Low-Cost, USB Connected and Multi-Purpose Biopotential Recording System. A Fast Respiratory Rate Estimation Method using Joint Sparse Signal Reconstruction based on Regularized Sparsity Adaptive Matching Pursuit.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1