热气候条件下双层幕墙的发展与应用综述

IF 1.2 Q3 MULTIDISCIPLINARY SCIENCES ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY Pub Date : 2021-12-20 DOI:10.14500/aro.10859
Aare N. Abtar
{"title":"热气候条件下双层幕墙的发展与应用综述","authors":"Aare N. Abtar","doi":"10.14500/aro.10859","DOIUrl":null,"url":null,"abstract":"A double-skin façade (DSF) is a multilayered skin that was initially designed for the cold climate of European countries with noticeable success. Since then, countries in different climates started looking into the possibility of adopting DSF through the use of computer simulations to avoid any unforeseen problems in real life. This study aims to look into the possibility and level of success in using DSF in the Middle East’s hot-arid climate, making it a challenge compared to European countries. The study utilized a quantitative investigative approach in analyzing the results of some studies done in different countries in the Middle East. After looking into the results from different papers, careful considerations have to be made for the building due to its location and microclimate todetermine specific parameters (e.g., combination of transparent and opaque materials, proportion between floor level and screen height, orientation and cavity depth), these would lead to a significant impact on reducing a building’s cooling loads and energy efficiency. It is worth noting that mechanical ventilation (e.g., supplying all return cool air from internal spaces into the DSF cavity or integrating the building’s heating, ventilation, and air-conditioning system with the façade) is necessary for DSF in hot climates to cool and maintain its cavity’s temperature to function properly. However, this increases cooling loads, energy consumption, and running costs of the building which architects have to consider to determine the most efficient and economical solution in material and equipment. \n ","PeriodicalId":8398,"journal":{"name":"ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2021-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A Review of the Development and Applicability of Double-Skin Facades in Hot Climates\",\"authors\":\"Aare N. Abtar\",\"doi\":\"10.14500/aro.10859\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A double-skin façade (DSF) is a multilayered skin that was initially designed for the cold climate of European countries with noticeable success. Since then, countries in different climates started looking into the possibility of adopting DSF through the use of computer simulations to avoid any unforeseen problems in real life. This study aims to look into the possibility and level of success in using DSF in the Middle East’s hot-arid climate, making it a challenge compared to European countries. The study utilized a quantitative investigative approach in analyzing the results of some studies done in different countries in the Middle East. After looking into the results from different papers, careful considerations have to be made for the building due to its location and microclimate todetermine specific parameters (e.g., combination of transparent and opaque materials, proportion between floor level and screen height, orientation and cavity depth), these would lead to a significant impact on reducing a building’s cooling loads and energy efficiency. It is worth noting that mechanical ventilation (e.g., supplying all return cool air from internal spaces into the DSF cavity or integrating the building’s heating, ventilation, and air-conditioning system with the façade) is necessary for DSF in hot climates to cool and maintain its cavity’s temperature to function properly. However, this increases cooling loads, energy consumption, and running costs of the building which architects have to consider to determine the most efficient and economical solution in material and equipment. \\n \",\"PeriodicalId\":8398,\"journal\":{\"name\":\"ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2021-12-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14500/aro.10859\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14500/aro.10859","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 1

摘要

双层皮肤farade (DSF)是一种多层皮肤,最初是为欧洲国家的寒冷气候而设计的,取得了显著的成功。从那时起,不同气候的国家开始通过使用计算机模拟研究采用DSF的可能性,以避免在现实生活中出现任何不可预见的问题。本研究旨在探讨在中东炎热干旱气候中使用DSF的可能性和成功程度,与欧洲国家相比,这是一个挑战。本研究采用定量调查的方法分析了在中东不同国家进行的一些研究的结果。在研究了不同论文的结果后,必须仔细考虑建筑物的位置和微气候,以确定具体参数(例如,透明和不透明材料的组合,地板水平和屏幕高度之间的比例,朝向和腔深),这些将对减少建筑物的冷负荷和能源效率产生重大影响。值得注意的是,机械通风(例如,将所有从内部空间返回的冷空气供应到DSF腔内或将建筑物的采暖,通风和空调系统与立面集成)对于炎热气候下的DSF来说是必要的,以冷却并保持其腔内的温度以正常运行。然而,这增加了建筑的冷却负荷、能源消耗和运行成本,建筑师必须考虑这些因素,以确定最有效和最经济的材料和设备解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Review of the Development and Applicability of Double-Skin Facades in Hot Climates
A double-skin façade (DSF) is a multilayered skin that was initially designed for the cold climate of European countries with noticeable success. Since then, countries in different climates started looking into the possibility of adopting DSF through the use of computer simulations to avoid any unforeseen problems in real life. This study aims to look into the possibility and level of success in using DSF in the Middle East’s hot-arid climate, making it a challenge compared to European countries. The study utilized a quantitative investigative approach in analyzing the results of some studies done in different countries in the Middle East. After looking into the results from different papers, careful considerations have to be made for the building due to its location and microclimate todetermine specific parameters (e.g., combination of transparent and opaque materials, proportion between floor level and screen height, orientation and cavity depth), these would lead to a significant impact on reducing a building’s cooling loads and energy efficiency. It is worth noting that mechanical ventilation (e.g., supplying all return cool air from internal spaces into the DSF cavity or integrating the building’s heating, ventilation, and air-conditioning system with the façade) is necessary for DSF in hot climates to cool and maintain its cavity’s temperature to function properly. However, this increases cooling loads, energy consumption, and running costs of the building which architects have to consider to determine the most efficient and economical solution in material and equipment.  
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY
ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY MULTIDISCIPLINARY SCIENCES-
自引率
33.30%
发文量
33
审稿时长
16 weeks
期刊最新文献
Encryption of Color Images with a New Framework Microstrip Passive Components for Energy Harvesting and 5G Applications Optimizing Emotional Insight through Unimodal and Multimodal Long Short-term Memory Models A Review on Adverse Drug Reaction Detection Techniques Deep Learning-Based Optical Music Recognition for Semantic Representation of Non-overlap and Overlap Music Notes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1