不再低效的原油脱盐——双频技术突破瓶颈,降低总拥有成本

Prabhu Elumalai, G. Sams, Umanath Subramani, Pinkesh Sanghani
{"title":"不再低效的原油脱盐——双频技术突破瓶颈,降低总拥有成本","authors":"Prabhu Elumalai, G. Sams, Umanath Subramani, Pinkesh Sanghani","doi":"10.2523/iptc-22365-ms","DOIUrl":null,"url":null,"abstract":"\n Historically, the engineering and operations teams in refineries have been constantly challenged to deploy efficient solutions for their crude desalting processes as part of the crude distillation unit (CDU). Inefficient crude oil desalting employing AC technology leads to higher utility consumption and corrosion-related issues with downstream equipment that create multiple bottlenecks while processing opportunity crudes. In addition, these challenges lead to a significant increase in operating expenses due to processing upsets and subsequent downtime.\n A major independent crude oil refinery in Asia is processing crude oil in two CDUs utilizing an AC technology desalting system. The total design capacity for the CDU is 206,000 BPD. The first CDU desalting equipment is designed for 150,000 BPD, and the second CDU is designed for 56,000 BPD. Both CDUs were operated in a range of 10 to 30 PTB inlet salinity. However, due to inefficient desalting, less than 60% desalting efficiency was achieved for each train with subsequent low dehydration efficiency. This led to a considerable bottleneck with the processing capacity and much higher chemical consumption, accompanied by frequent upsets and operational issues on downstream equipment.\n After a review of the entire desalting operations, the CDU 1 desalter vessel was upgraded to dual frequency technology, and a new dual frequency desalter was installed at the second stage of CDU 2. This change provided a paradigm shift in handling opportunity crude blends in the range of crude density 21 to 28° API with the flexibility of 20 to 100 PTB inlet salinity. After the upgrade, the CDUs achieved a desalting efficiency of more than 90% on each stage and more than 99% on two stages.\n This paper examines the project from early engagement through conceptual technology selection phase, engineering design, and project execution leading to a successful startup backed by operational history. Furthermore, the adoption of dual frequency technology over legacy AC technology demonstrates the twin goals of positive economic and environmental stewardship, thereby lowering the total cost of ownership to the customer.\n The CDU 1 dual frequency technology retrofit has been in continuous operation since 2019 and performing well within the PTB outlet specifications. The system is running with 40 to 50 % lower utility consumption, both chemical and power savings with reduced downstream corrosion and an increase in uptime reliability.","PeriodicalId":10974,"journal":{"name":"Day 2 Tue, February 22, 2022","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"No More Inefficient Crude Desalting - Breaking Bottleneck with Dual Frequency Technology Lowering Total Cost of Ownership\",\"authors\":\"Prabhu Elumalai, G. Sams, Umanath Subramani, Pinkesh Sanghani\",\"doi\":\"10.2523/iptc-22365-ms\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Historically, the engineering and operations teams in refineries have been constantly challenged to deploy efficient solutions for their crude desalting processes as part of the crude distillation unit (CDU). Inefficient crude oil desalting employing AC technology leads to higher utility consumption and corrosion-related issues with downstream equipment that create multiple bottlenecks while processing opportunity crudes. In addition, these challenges lead to a significant increase in operating expenses due to processing upsets and subsequent downtime.\\n A major independent crude oil refinery in Asia is processing crude oil in two CDUs utilizing an AC technology desalting system. The total design capacity for the CDU is 206,000 BPD. The first CDU desalting equipment is designed for 150,000 BPD, and the second CDU is designed for 56,000 BPD. Both CDUs were operated in a range of 10 to 30 PTB inlet salinity. However, due to inefficient desalting, less than 60% desalting efficiency was achieved for each train with subsequent low dehydration efficiency. This led to a considerable bottleneck with the processing capacity and much higher chemical consumption, accompanied by frequent upsets and operational issues on downstream equipment.\\n After a review of the entire desalting operations, the CDU 1 desalter vessel was upgraded to dual frequency technology, and a new dual frequency desalter was installed at the second stage of CDU 2. This change provided a paradigm shift in handling opportunity crude blends in the range of crude density 21 to 28° API with the flexibility of 20 to 100 PTB inlet salinity. After the upgrade, the CDUs achieved a desalting efficiency of more than 90% on each stage and more than 99% on two stages.\\n This paper examines the project from early engagement through conceptual technology selection phase, engineering design, and project execution leading to a successful startup backed by operational history. Furthermore, the adoption of dual frequency technology over legacy AC technology demonstrates the twin goals of positive economic and environmental stewardship, thereby lowering the total cost of ownership to the customer.\\n The CDU 1 dual frequency technology retrofit has been in continuous operation since 2019 and performing well within the PTB outlet specifications. The system is running with 40 to 50 % lower utility consumption, both chemical and power savings with reduced downstream corrosion and an increase in uptime reliability.\",\"PeriodicalId\":10974,\"journal\":{\"name\":\"Day 2 Tue, February 22, 2022\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-02-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Day 2 Tue, February 22, 2022\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2523/iptc-22365-ms\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 2 Tue, February 22, 2022","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2523/iptc-22365-ms","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

从历史上看,炼油厂的工程和运营团队一直面临着为原油脱盐过程(作为原油蒸馏装置(CDU)的一部分)部署高效解决方案的挑战。采用交流技术的原油脱盐效率低下,导致了更高的公用事业消耗和下游设备的腐蚀问题,在处理机会原油时产生了多个瓶颈。此外,由于加工中断和随后的停机时间,这些挑战导致运营费用大幅增加。亚洲的一家大型独立炼油厂正在利用AC技术脱盐系统,在两个cdu内处理原油。CDU的总设计容量为20.6万桶/天。第一台CDU脱盐设备的设计能力为150,000 BPD,第二台CDU的设计能力为56,000 BPD。两个cdu都在10 - 30ptb的进口盐度范围内工作。但由于脱盐效率低,每列脱盐效率不足60%,脱水效率较低。这导致了相当大的处理能力瓶颈和更高的化学品消耗,伴随着下游设备频繁的故障和操作问题。在对整个脱盐操作进行审查后,CDU 1脱盐容器升级为双频技术,并在CDU 2的第二阶段安装了新的双频脱盐器。这一变化为原油密度在21 ~ 28°API范围内、进口盐度在20 ~ 100 PTB范围内处理原油混合物提供了一种范式转变。升级后,cdu每级脱盐效率均超过90%,两级脱盐效率均超过99%。本文考察了项目从早期参与到概念技术选择阶段、工程设计和项目执行,从而在运营历史的支持下成功启动。此外,采用双频技术而不是传统的交流技术表明了积极的经济和环境管理的双重目标,从而降低了客户的总拥有成本。CDU 1双频技术改造自2019年以来一直在持续运行,并在PTB出口规格内表现良好。该系统的运行能耗降低了40%至50%,不仅减少了化学品和电力消耗,还减少了下游腐蚀,提高了正常运行时间的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
No More Inefficient Crude Desalting - Breaking Bottleneck with Dual Frequency Technology Lowering Total Cost of Ownership
Historically, the engineering and operations teams in refineries have been constantly challenged to deploy efficient solutions for their crude desalting processes as part of the crude distillation unit (CDU). Inefficient crude oil desalting employing AC technology leads to higher utility consumption and corrosion-related issues with downstream equipment that create multiple bottlenecks while processing opportunity crudes. In addition, these challenges lead to a significant increase in operating expenses due to processing upsets and subsequent downtime. A major independent crude oil refinery in Asia is processing crude oil in two CDUs utilizing an AC technology desalting system. The total design capacity for the CDU is 206,000 BPD. The first CDU desalting equipment is designed for 150,000 BPD, and the second CDU is designed for 56,000 BPD. Both CDUs were operated in a range of 10 to 30 PTB inlet salinity. However, due to inefficient desalting, less than 60% desalting efficiency was achieved for each train with subsequent low dehydration efficiency. This led to a considerable bottleneck with the processing capacity and much higher chemical consumption, accompanied by frequent upsets and operational issues on downstream equipment. After a review of the entire desalting operations, the CDU 1 desalter vessel was upgraded to dual frequency technology, and a new dual frequency desalter was installed at the second stage of CDU 2. This change provided a paradigm shift in handling opportunity crude blends in the range of crude density 21 to 28° API with the flexibility of 20 to 100 PTB inlet salinity. After the upgrade, the CDUs achieved a desalting efficiency of more than 90% on each stage and more than 99% on two stages. This paper examines the project from early engagement through conceptual technology selection phase, engineering design, and project execution leading to a successful startup backed by operational history. Furthermore, the adoption of dual frequency technology over legacy AC technology demonstrates the twin goals of positive economic and environmental stewardship, thereby lowering the total cost of ownership to the customer. The CDU 1 dual frequency technology retrofit has been in continuous operation since 2019 and performing well within the PTB outlet specifications. The system is running with 40 to 50 % lower utility consumption, both chemical and power savings with reduced downstream corrosion and an increase in uptime reliability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Newly Designed High Expansion Through-Tubing Bridge Plug Service to Reduce Operational Costs and Increase Reliability Pore Geometry Effect on Si, Trapping and Sor in Tight Carbonate Reservoirs Auto-Curve: Downhole Trajectory Automation with Cost Reduction to the Operator by Reducing the Time-to-Target Optimization and Thermal Performance Assessment of Elliptical Pin-Fin Heat Sinks Three-Phase Saturation Evaluation Using Advanced Pulsed Neutron Measurement
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1