木质护墙板湿度无损检测方法的可靠性研究

Toshie Takahashi, H. Tsutsumi, M. Nakajima, T. Mitamura
{"title":"木质护墙板湿度无损检测方法的可靠性研究","authors":"Toshie Takahashi, H. Tsutsumi, M. Nakajima, T. Mitamura","doi":"10.2472/JSMS.64.203","DOIUrl":null,"url":null,"abstract":"For minimizing the effects of housing deterioration, it must be established a simple and precise inspection to examine the house condition. In this study, the behavior of humidity in wooden sheathed wall of housing outer wall was considered. The humidity, which was observed in the walls, was compared with non-destructive inspection data, the temperature and the humidity observed inside and outside of the wall. Non-destructive inspection data was (cid:3) classified and inspected according to their observed position, their specification and environment. As a result, the boundary of the humidity in the wall, which has effect on the housing deterioration, was estimated from 64% to 67%. The reliability of non-destructive inspection method was indicated by Bayes method, therefore the humidity inspection with electrical resistance devices is more reliable than the inspection with high frequency devices. With the electrical resistance devices, the non-destructive inspection on lower position mortar wall is useful on the humidity inspection in wooden sheathed walls. The humidity in the wall is affected by the environment, specification and the observed position.","PeriodicalId":17366,"journal":{"name":"journal of the Japan Society for Testing Materials","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability on the Non-destructive Inspection Method for the Humidity in Wooden Sheathed Walls\",\"authors\":\"Toshie Takahashi, H. Tsutsumi, M. Nakajima, T. Mitamura\",\"doi\":\"10.2472/JSMS.64.203\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For minimizing the effects of housing deterioration, it must be established a simple and precise inspection to examine the house condition. In this study, the behavior of humidity in wooden sheathed wall of housing outer wall was considered. The humidity, which was observed in the walls, was compared with non-destructive inspection data, the temperature and the humidity observed inside and outside of the wall. Non-destructive inspection data was (cid:3) classified and inspected according to their observed position, their specification and environment. As a result, the boundary of the humidity in the wall, which has effect on the housing deterioration, was estimated from 64% to 67%. The reliability of non-destructive inspection method was indicated by Bayes method, therefore the humidity inspection with electrical resistance devices is more reliable than the inspection with high frequency devices. With the electrical resistance devices, the non-destructive inspection on lower position mortar wall is useful on the humidity inspection in wooden sheathed walls. The humidity in the wall is affected by the environment, specification and the observed position.\",\"PeriodicalId\":17366,\"journal\":{\"name\":\"journal of the Japan Society for Testing Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"journal of the Japan Society for Testing Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2472/JSMS.64.203\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"journal of the Japan Society for Testing Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2472/JSMS.64.203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了尽量减少房屋恶化的影响,必须建立一个简单而精确的检查房屋状况的方法。本文研究了房屋外墙木护墙内的湿度变化规律。将墙体内观察到的湿度与无损检测数据、墙体内外观察到的温度和湿度进行比较。对无损检测数据(cid:3)按其观察位置、规格和环境进行分类和检验。结果表明,墙体湿度对房屋劣化的影响范围为64% ~ 67%。用贝叶斯方法表明了无损检测方法的可靠性,因此电阻式湿度检测比高频式湿度检测更可靠。采用电阻装置对下部砂浆墙体进行无损检测,可用于木护套墙体的湿度检测。墙体湿度受环境、规格和观察位置的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reliability on the Non-destructive Inspection Method for the Humidity in Wooden Sheathed Walls
For minimizing the effects of housing deterioration, it must be established a simple and precise inspection to examine the house condition. In this study, the behavior of humidity in wooden sheathed wall of housing outer wall was considered. The humidity, which was observed in the walls, was compared with non-destructive inspection data, the temperature and the humidity observed inside and outside of the wall. Non-destructive inspection data was (cid:3) classified and inspected according to their observed position, their specification and environment. As a result, the boundary of the humidity in the wall, which has effect on the housing deterioration, was estimated from 64% to 67%. The reliability of non-destructive inspection method was indicated by Bayes method, therefore the humidity inspection with electrical resistance devices is more reliable than the inspection with high frequency devices. With the electrical resistance devices, the non-destructive inspection on lower position mortar wall is useful on the humidity inspection in wooden sheathed walls. The humidity in the wall is affected by the environment, specification and the observed position.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of In-Situ Iron Powder Mixing Treatment with Air Bubbles Using Deep Mixing Method Revised Design Models for Geogrid Reinforced Soil Walls and LRFD Calibration Quantitative Characterization of the Changes in Surface Topography of Austenitic Stainless Steel under Low Cycle Fatigue Loading Service Life Prediction of an Aged Bridge Based on Carbonation Tests of Cross-Section Cutting-Off Girders 静的強度特性値による機械構造用炭素鋼のS-N 曲線に関する統計的推定
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1