{"title":"巩膜晶状体磨损过程中晶状体后撕裂层厚度的区域差异。","authors":"Stephen J. Vincent, D. Alonso-Caneiro, M. Collins","doi":"10.1097/ICL.0000000000000676","DOIUrl":null,"url":null,"abstract":"OBJECTIVES\nTo quantify regional variations in the postlens tear layer (PLTL) thickness during scleral lens wear.\n\n\nMETHODS\nFifteen healthy adults (22±3 years) with normal corneae were fitted with a 16.5-mm-diameter rotationally symmetric scleral lens in one eye. The PLTL thickness was measured across the central 5 mm at 0, 15, 30, 45, 60, 90, 120, 240, and 480 min after lens insertion using a 12 radial line scan optical coherence tomography imaging protocol. Regional analyses were conducted by dividing the PLTL into 8 equal 45° segments.\n\n\nRESULTS\nA tilted optic zone was observed immediately after lens insertion with the greatest PLTL asymmetry between nasal and temporal regions (156±22 μm more clearance temporally) and superior nasal and inferotemporal regions (124±12 μm more clearance inferotemporally). The magnitude of lens settling observed in each region was associated with the initial PLTL (r=0.59-0.77, P≤0.02). The superior nasal PLTL furthest from the pupil center stabilized after 90 min compared with other regions which stabilized after 4 hr. On average, after 8 hr of lens wear, the PLTL decreased by 29% and PLTL asymmetries between opposing regions decreased by 30%.\n\n\nCONCLUSIONS\nThe PLTL was thickest temporally and thinnest nasally in healthy eyes fitted with rotationally symmetric scleral lenses, most likely because of regional differences in underlying scleral elevation, eyelid forces, and lens centration. Postlens tear layer asymmetries diminished with lens wear, and stabilization occurred more rapidly in regions with less corneal clearance immediately after lens insertion.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"24 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Regional Variations in Postlens Tear Layer Thickness During Scleral Lens Wear.\",\"authors\":\"Stephen J. Vincent, D. Alonso-Caneiro, M. Collins\",\"doi\":\"10.1097/ICL.0000000000000676\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"OBJECTIVES\\nTo quantify regional variations in the postlens tear layer (PLTL) thickness during scleral lens wear.\\n\\n\\nMETHODS\\nFifteen healthy adults (22±3 years) with normal corneae were fitted with a 16.5-mm-diameter rotationally symmetric scleral lens in one eye. The PLTL thickness was measured across the central 5 mm at 0, 15, 30, 45, 60, 90, 120, 240, and 480 min after lens insertion using a 12 radial line scan optical coherence tomography imaging protocol. Regional analyses were conducted by dividing the PLTL into 8 equal 45° segments.\\n\\n\\nRESULTS\\nA tilted optic zone was observed immediately after lens insertion with the greatest PLTL asymmetry between nasal and temporal regions (156±22 μm more clearance temporally) and superior nasal and inferotemporal regions (124±12 μm more clearance inferotemporally). The magnitude of lens settling observed in each region was associated with the initial PLTL (r=0.59-0.77, P≤0.02). The superior nasal PLTL furthest from the pupil center stabilized after 90 min compared with other regions which stabilized after 4 hr. On average, after 8 hr of lens wear, the PLTL decreased by 29% and PLTL asymmetries between opposing regions decreased by 30%.\\n\\n\\nCONCLUSIONS\\nThe PLTL was thickest temporally and thinnest nasally in healthy eyes fitted with rotationally symmetric scleral lenses, most likely because of regional differences in underlying scleral elevation, eyelid forces, and lens centration. Postlens tear layer asymmetries diminished with lens wear, and stabilization occurred more rapidly in regions with less corneal clearance immediately after lens insertion.\",\"PeriodicalId\":12216,\"journal\":{\"name\":\"Eye & Contact Lens: Science & Clinical Practice\",\"volume\":\"24 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye & Contact Lens: Science & Clinical Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/ICL.0000000000000676\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens: Science & Clinical Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000000676","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Regional Variations in Postlens Tear Layer Thickness During Scleral Lens Wear.
OBJECTIVES
To quantify regional variations in the postlens tear layer (PLTL) thickness during scleral lens wear.
METHODS
Fifteen healthy adults (22±3 years) with normal corneae were fitted with a 16.5-mm-diameter rotationally symmetric scleral lens in one eye. The PLTL thickness was measured across the central 5 mm at 0, 15, 30, 45, 60, 90, 120, 240, and 480 min after lens insertion using a 12 radial line scan optical coherence tomography imaging protocol. Regional analyses were conducted by dividing the PLTL into 8 equal 45° segments.
RESULTS
A tilted optic zone was observed immediately after lens insertion with the greatest PLTL asymmetry between nasal and temporal regions (156±22 μm more clearance temporally) and superior nasal and inferotemporal regions (124±12 μm more clearance inferotemporally). The magnitude of lens settling observed in each region was associated with the initial PLTL (r=0.59-0.77, P≤0.02). The superior nasal PLTL furthest from the pupil center stabilized after 90 min compared with other regions which stabilized after 4 hr. On average, after 8 hr of lens wear, the PLTL decreased by 29% and PLTL asymmetries between opposing regions decreased by 30%.
CONCLUSIONS
The PLTL was thickest temporally and thinnest nasally in healthy eyes fitted with rotationally symmetric scleral lenses, most likely because of regional differences in underlying scleral elevation, eyelid forces, and lens centration. Postlens tear layer asymmetries diminished with lens wear, and stabilization occurred more rapidly in regions with less corneal clearance immediately after lens insertion.