{"title":"NaI(Tl)伽马射线谱仪温度峰移的非线性校正方法","authors":"Jinfei Wu, Juan Zhai, Wanchang Lai, Hongjian Lin, Chenhao Zeng, Runqiu Gu, Shaoqin Li, Yunrui Jiang, Jie Shi, Bo Zhang","doi":"10.1155/2023/1590667","DOIUrl":null,"url":null,"abstract":"NaI(Tl) detectors are frequently operated under unstable temperature conditions when used in an open environment. Temperature changes would result in a peak shift and spectral distortion during measurement. Two easy-to-implement methodologies are proposed to stabilize the measured spectrum without the necessity of adjusting the gain, which are a correction algorithm for temperature-caused peak-shift based on multiple characteristic peak area weighting factors and an interpolation correction algorithm based on multicharacteristic peak sequence. Both of them can be used when the relative channel displacement of characteristic peaks in the spectrum due to temperature changes is not constant. Experimental data obtained under controlled temperature conditions in the laboratory were adopted to correct a spectrum, with joint consideration of some known characteristic peaks, such as 40K, U (214Bi), or Th (208Tl) peaks. Through constructing a reversible temperature coefficient matrix, one can easily obtain the coefficients of the n-th polynomial describing the influence of temperature on peak position, which presents their nonlinear mathematical relationship. Then, corrections of these two effects can also be easily calculated. Comparing the experimental results, peak positions before and after correction, it is proved that the interpolation correction algorithm based on multicharacteristic peak sequence has better correction accuracy, but the temperature-caused peak shift correction algorithm based on the multicharacteristic peak area weighting factor has a shorter calibration time.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Nonlinear Correction Methods of Temperature-Caused Peak Shift for a NaI(Tl) Gamma-Ray Spectrometer\",\"authors\":\"Jinfei Wu, Juan Zhai, Wanchang Lai, Hongjian Lin, Chenhao Zeng, Runqiu Gu, Shaoqin Li, Yunrui Jiang, Jie Shi, Bo Zhang\",\"doi\":\"10.1155/2023/1590667\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"NaI(Tl) detectors are frequently operated under unstable temperature conditions when used in an open environment. Temperature changes would result in a peak shift and spectral distortion during measurement. Two easy-to-implement methodologies are proposed to stabilize the measured spectrum without the necessity of adjusting the gain, which are a correction algorithm for temperature-caused peak-shift based on multiple characteristic peak area weighting factors and an interpolation correction algorithm based on multicharacteristic peak sequence. Both of them can be used when the relative channel displacement of characteristic peaks in the spectrum due to temperature changes is not constant. Experimental data obtained under controlled temperature conditions in the laboratory were adopted to correct a spectrum, with joint consideration of some known characteristic peaks, such as 40K, U (214Bi), or Th (208Tl) peaks. Through constructing a reversible temperature coefficient matrix, one can easily obtain the coefficients of the n-th polynomial describing the influence of temperature on peak position, which presents their nonlinear mathematical relationship. Then, corrections of these two effects can also be easily calculated. Comparing the experimental results, peak positions before and after correction, it is proved that the interpolation correction algorithm based on multicharacteristic peak sequence has better correction accuracy, but the temperature-caused peak shift correction algorithm based on the multicharacteristic peak area weighting factor has a shorter calibration time.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-02-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1155/2023/1590667\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1155/2023/1590667","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

在开放环境中,NaI(Tl)探测器经常在不稳定的温度条件下工作。温度变化会导致测量过程中的峰移和光谱失真。提出了两种易于实现的无需调整增益即可稳定测量光谱的方法,即基于多特征峰面积加权因子的温度引起的峰移校正算法和基于多特征峰序列的插值校正算法。当光谱中特征峰的相对通道位移由于温度变化而不恒定时,两者都可以使用。采用在实验室控制温度条件下获得的实验数据,并联合考虑一些已知的特征峰,如40K, U (214Bi)或Th (208Tl)峰,对光谱进行校正。通过构造一个可逆的温度系数矩阵,可以很容易地得到描述温度对峰值位置影响的第n个多项式的系数,从而表示出它们之间的非线性数学关系。然后,这两种效应的修正也可以很容易地计算出来。对比实验结果和校正前后的峰值位置,证明基于多特征峰序列的插值校正算法具有更好的校正精度,而基于多特征峰面积加权因子的温度引起的峰移校正算法校正时间更短。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Nonlinear Correction Methods of Temperature-Caused Peak Shift for a NaI(Tl) Gamma-Ray Spectrometer
NaI(Tl) detectors are frequently operated under unstable temperature conditions when used in an open environment. Temperature changes would result in a peak shift and spectral distortion during measurement. Two easy-to-implement methodologies are proposed to stabilize the measured spectrum without the necessity of adjusting the gain, which are a correction algorithm for temperature-caused peak-shift based on multiple characteristic peak area weighting factors and an interpolation correction algorithm based on multicharacteristic peak sequence. Both of them can be used when the relative channel displacement of characteristic peaks in the spectrum due to temperature changes is not constant. Experimental data obtained under controlled temperature conditions in the laboratory were adopted to correct a spectrum, with joint consideration of some known characteristic peaks, such as 40K, U (214Bi), or Th (208Tl) peaks. Through constructing a reversible temperature coefficient matrix, one can easily obtain the coefficients of the n-th polynomial describing the influence of temperature on peak position, which presents their nonlinear mathematical relationship. Then, corrections of these two effects can also be easily calculated. Comparing the experimental results, peak positions before and after correction, it is proved that the interpolation correction algorithm based on multicharacteristic peak sequence has better correction accuracy, but the temperature-caused peak shift correction algorithm based on the multicharacteristic peak area weighting factor has a shorter calibration time.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Management of Cholesteatoma: Hearing Rehabilitation. Congenital Cholesteatoma. Evaluation of Cholesteatoma. Management of Cholesteatoma: Extension Beyond Middle Ear/Mastoid. Recidivism and Recurrence.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1