{"title":"高灵敏度碳同位素技术的应用——一个空白问题","authors":"P.D. Yates, I.P. Wright, C.T. Pillinger","doi":"10.1016/0009-2541(92)90205-J","DOIUrl":null,"url":null,"abstract":"<div><p>The performance of a new carbon stable isotope static mass spectrometer over the sample size range 10 pmol to 1 nmol is reviewed with reference to standard data gathered over a year of operation. Specimens of known isotopic composition and zero enrichment tests suggest that the instrument is accurate to within±0.5‰ over the entire sample size range, with precision only becoming worse than∼±;1‰at< 80pmol. Efforts to obtain “blanks” compatible with the above performance are also reviewed. A procedure is available which controls the total blank in a stepped combustion, from room temperature to 1200°C, to 1 nmol; in the temperature range of most inserest for extraterrestrial samples (600–1200°C),⩽50pmol can be achieved. However, a real benefit of the new instrument is that isotopic compositions of the blanks can be accurately obtained, so allowing a proper assessment of its causes and a correction of sample data if desired.</p></div>","PeriodicalId":100231,"journal":{"name":"Chemical Geology: Isotope Geoscience section","volume":"101 1","pages":"Pages 81-91"},"PeriodicalIF":0.0000,"publicationDate":"1992-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0009-2541(92)90205-J","citationCount":"13","resultStr":"{\"title\":\"Application of high-sensitivity carbon isotope techniques— a question of blanks\",\"authors\":\"P.D. Yates, I.P. Wright, C.T. Pillinger\",\"doi\":\"10.1016/0009-2541(92)90205-J\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The performance of a new carbon stable isotope static mass spectrometer over the sample size range 10 pmol to 1 nmol is reviewed with reference to standard data gathered over a year of operation. Specimens of known isotopic composition and zero enrichment tests suggest that the instrument is accurate to within±0.5‰ over the entire sample size range, with precision only becoming worse than∼±;1‰at< 80pmol. Efforts to obtain “blanks” compatible with the above performance are also reviewed. A procedure is available which controls the total blank in a stepped combustion, from room temperature to 1200°C, to 1 nmol; in the temperature range of most inserest for extraterrestrial samples (600–1200°C),⩽50pmol can be achieved. However, a real benefit of the new instrument is that isotopic compositions of the blanks can be accurately obtained, so allowing a proper assessment of its causes and a correction of sample data if desired.</p></div>\",\"PeriodicalId\":100231,\"journal\":{\"name\":\"Chemical Geology: Isotope Geoscience section\",\"volume\":\"101 1\",\"pages\":\"Pages 81-91\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0009-2541(92)90205-J\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chemical Geology: Isotope Geoscience section\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/000925419290205J\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemical Geology: Isotope Geoscience section","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/000925419290205J","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Application of high-sensitivity carbon isotope techniques— a question of blanks
The performance of a new carbon stable isotope static mass spectrometer over the sample size range 10 pmol to 1 nmol is reviewed with reference to standard data gathered over a year of operation. Specimens of known isotopic composition and zero enrichment tests suggest that the instrument is accurate to within±0.5‰ over the entire sample size range, with precision only becoming worse than∼±;1‰at< 80pmol. Efforts to obtain “blanks” compatible with the above performance are also reviewed. A procedure is available which controls the total blank in a stepped combustion, from room temperature to 1200°C, to 1 nmol; in the temperature range of most inserest for extraterrestrial samples (600–1200°C),⩽50pmol can be achieved. However, a real benefit of the new instrument is that isotopic compositions of the blanks can be accurately obtained, so allowing a proper assessment of its causes and a correction of sample data if desired.