K. R. Kumar, T. S. Anandhi, B. Vijayakrishna, S. Balakumar
{"title":"KY升压变换器有效控制器的建模、仿真与实现","authors":"K. R. Kumar, T. S. Anandhi, B. Vijayakrishna, S. Balakumar","doi":"10.1155/2022/8495432","DOIUrl":null,"url":null,"abstract":"This paper studies on a new Hybrid Posicast Control (HPC) for Fundamental KY Boost Converter (FKYBC) worked in Continuous Current Mode (CCM). Posicast is a feed-forward compensator. It reduces the overshoot in the step result of the flippantly damped plant. But the conventional controller approach is sensitive owing to the changes in the natural frequency. So, as to reduce this undesirable sensitivity and load potential control of FKYBC, a HPC is designed in this article. Structure of HPC is posicast with feedback loop. The independent computational time delay is the main design function of the posicast. The enactment of the FKYBC with HPC is confirmed at various operating regions by making the MATLAB/Simulink and experimental model. The posicast function values are implemented in Arduino Uno-ATmega328P microcontroller. The results of new HPC have produced minimal noise in control signal in comparison with traditional PID control.","PeriodicalId":45541,"journal":{"name":"Modelling and Simulation in Engineering","volume":"125 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2022-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Modelling, Simulation, and Implementation of Effective Controller for KY Stepping Up Converter\",\"authors\":\"K. R. Kumar, T. S. Anandhi, B. Vijayakrishna, S. Balakumar\",\"doi\":\"10.1155/2022/8495432\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper studies on a new Hybrid Posicast Control (HPC) for Fundamental KY Boost Converter (FKYBC) worked in Continuous Current Mode (CCM). Posicast is a feed-forward compensator. It reduces the overshoot in the step result of the flippantly damped plant. But the conventional controller approach is sensitive owing to the changes in the natural frequency. So, as to reduce this undesirable sensitivity and load potential control of FKYBC, a HPC is designed in this article. Structure of HPC is posicast with feedback loop. The independent computational time delay is the main design function of the posicast. The enactment of the FKYBC with HPC is confirmed at various operating regions by making the MATLAB/Simulink and experimental model. The posicast function values are implemented in Arduino Uno-ATmega328P microcontroller. The results of new HPC have produced minimal noise in control signal in comparison with traditional PID control.\",\"PeriodicalId\":45541,\"journal\":{\"name\":\"Modelling and Simulation in Engineering\",\"volume\":\"125 1\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2022-01-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Modelling and Simulation in Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2022/8495432\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Modelling and Simulation in Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2022/8495432","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 3
摘要
研究了工作在连续电流模式(CCM)下的基基KY升压变换器(FKYBC)的一种新型混合后播控制(HPC)。Posicast是一种前馈补偿器。它减少了轻阻尼装置的阶跃结果中的超调。但传统的控制方法由于固有频率的变化而变得敏感。因此,为了减少FKYBC的不良灵敏度和负载电位控制,本文设计了一种HPC。HPC的结构是带反馈环的posast结构。独立的计算时延是posicast的主要设计功能。通过制作MATLAB/Simulink和实验模型,验证了HPC对FKYBC在不同工作区域的运行效果。posicast函数值在Arduino uni - atmega328p微控制器中实现。结果表明,与传统的PID控制相比,新型HPC控制对控制信号产生的噪声最小。
Modelling, Simulation, and Implementation of Effective Controller for KY Stepping Up Converter
This paper studies on a new Hybrid Posicast Control (HPC) for Fundamental KY Boost Converter (FKYBC) worked in Continuous Current Mode (CCM). Posicast is a feed-forward compensator. It reduces the overshoot in the step result of the flippantly damped plant. But the conventional controller approach is sensitive owing to the changes in the natural frequency. So, as to reduce this undesirable sensitivity and load potential control of FKYBC, a HPC is designed in this article. Structure of HPC is posicast with feedback loop. The independent computational time delay is the main design function of the posicast. The enactment of the FKYBC with HPC is confirmed at various operating regions by making the MATLAB/Simulink and experimental model. The posicast function values are implemented in Arduino Uno-ATmega328P microcontroller. The results of new HPC have produced minimal noise in control signal in comparison with traditional PID control.
期刊介绍:
Modelling and Simulation in Engineering aims at providing a forum for the discussion of formalisms, methodologies and simulation tools that are intended to support the new, broader interpretation of Engineering. Competitive pressures of Global Economy have had a profound effect on the manufacturing in Europe, Japan and the USA with much of the production being outsourced. In this context the traditional interpretation of engineering profession linked to the actual manufacturing needs to be broadened to include the integration of outsourced components and the consideration of logistic, economical and human factors in the design of engineering products and services.