{"title":"400 kV y型复合横臂电场计算与优化","authors":"K. Yin, F. D. da Silva, C. Bak, Hanchi Zhang, Qian Wang, H. Skouboe","doi":"10.1109/ICEMPE51623.2021.9509173","DOIUrl":null,"url":null,"abstract":"A new proposed Y-shaped composite pylon has a potential to become the next new generation $2\\times 400\\text{kV}$ overhead line transmission tower. However, according to previous work, the electric field magnitudes inside the hollow cross-arm tube exceeds the onset electric field strength of corona, which does not meet the requirements of insulation. In this paper, an electrostatic field model is established by using finite element method analysis. Aiming to previous existing issues, we propose using low density polyethylene (LDPE) as filling material to fill the cross-arm. Meanwhile, the clamps structure is redesigned. Then, the electric field distribution results along the surface of the cross-arm and around the clamps are presented. Furthermore, through the shape optimization, the electric field distribution of clamps and sheds meets the design criteria. Finally, taking advantages of the insulation margin, the conductor enclosure is removed and the height of the clamp is decreased. The final clamp structure meets the insulation requirement.","PeriodicalId":7083,"journal":{"name":"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)","volume":"2 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Electric Field Computation and Optimization for A 400 kV Y-shaped Composite Cross-arm\",\"authors\":\"K. Yin, F. D. da Silva, C. Bak, Hanchi Zhang, Qian Wang, H. Skouboe\",\"doi\":\"10.1109/ICEMPE51623.2021.9509173\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new proposed Y-shaped composite pylon has a potential to become the next new generation $2\\\\times 400\\\\text{kV}$ overhead line transmission tower. However, according to previous work, the electric field magnitudes inside the hollow cross-arm tube exceeds the onset electric field strength of corona, which does not meet the requirements of insulation. In this paper, an electrostatic field model is established by using finite element method analysis. Aiming to previous existing issues, we propose using low density polyethylene (LDPE) as filling material to fill the cross-arm. Meanwhile, the clamps structure is redesigned. Then, the electric field distribution results along the surface of the cross-arm and around the clamps are presented. Furthermore, through the shape optimization, the electric field distribution of clamps and sheds meets the design criteria. Finally, taking advantages of the insulation margin, the conductor enclosure is removed and the height of the clamp is decreased. The final clamp structure meets the insulation requirement.\",\"PeriodicalId\":7083,\"journal\":{\"name\":\"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)\",\"volume\":\"2 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEMPE51623.2021.9509173\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMPE51623.2021.9509173","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

新提出的y形复合塔有可能成为下一代2\ × 400\ kV的架空线路输电塔。然而,根据以往的工作,空心横臂管内部的电场大小超过了电晕的起始电场强度,不符合绝缘要求。本文采用有限元法分析,建立了静电场模型。针对以往存在的问题,我们提出采用低密度聚乙烯(LDPE)作为填充材料来填充横臂。同时,对夹具结构进行了重新设计。然后给出了沿横臂表面和夹钳周围的电场分布结果。此外,通过形状优化,使夹钳和棚架的电场分布满足设计要求。最后,利用绝缘余量,除去导体外壳,减小钳的高度。最终夹具结构满足绝缘要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Electric Field Computation and Optimization for A 400 kV Y-shaped Composite Cross-arm
A new proposed Y-shaped composite pylon has a potential to become the next new generation $2\times 400\text{kV}$ overhead line transmission tower. However, according to previous work, the electric field magnitudes inside the hollow cross-arm tube exceeds the onset electric field strength of corona, which does not meet the requirements of insulation. In this paper, an electrostatic field model is established by using finite element method analysis. Aiming to previous existing issues, we propose using low density polyethylene (LDPE) as filling material to fill the cross-arm. Meanwhile, the clamps structure is redesigned. Then, the electric field distribution results along the surface of the cross-arm and around the clamps are presented. Furthermore, through the shape optimization, the electric field distribution of clamps and sheds meets the design criteria. Finally, taking advantages of the insulation margin, the conductor enclosure is removed and the height of the clamp is decreased. The final clamp structure meets the insulation requirement.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Thermal Stress Analysis of Epoxy Resin Encapsulated Solid State Transformer's Cracking Caused by Temperature Shock Study on the Arc Characteristics of Insulator Creeping Discharge under High Velocity Air Application of an improved ultraviolet spectrophotometry technology for the determination of antioxidants in natural ester liquids Noise analysis and device improvement of composite probe for space charge measuring based on PIPWP method Research on high voltage capacitor partial discharge detection with portable oscillating wave circuit
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1