{"title":"提高胶粘剂树脂转化度对两步自蚀刻胶粘剂牙本质粘接耐久性的影响。","authors":"Kento Sato, K. Hosaka, Masahiro Takahashi, M. Ikeda, F. Tian, W. Komada, M. Nakajima, R. Foxton, Y. Nishitani, D. Pashley, J. Tagami","doi":"10.3290/j.jad.a37726","DOIUrl":null,"url":null,"abstract":"PURPOSE To evaluate (1) the initial and long-term microtensile bond strengths of two-step self-etch adhesives with different degrees of conversion (DC); (2) the elastic modulus of the respective adhesive resins; (3) the water sorption of the respective adhesive resins. MATERIALS AND METHODS Two two-step self-etch adhesives, Clearfil SE Bond (CSE) and Clearfil SE Bond 2 (CSE2) were used in this study. The DC was determined using ATR/FT-IR with a time-based spectrum analysis. Midcoronal flat dentin surfaces of 24 human molars were prepared with 600-grit SiC paper for microtensile bond strength (µTBS) testing. CSE and CSE2 were applied to the dentin surfaces according to the manufacturer's instructions, followed by composite buildups. The µTBS was measured after water storage for 24 h, 6 months, and 1 year. The elastic modulus (before and after 1 month of water immersion) was determined by the three-point flexural bending test and water sorption values by the water sorption test. RESULTS CSE2 showed significantly higher DC than CSE. The µTBS of CSE2 was significantly higher than that of CSE in all water storage periods. One-year water storage decreased the µTBS of CSE; however, it did not decrease that of CSE2. Regarding the polymerized adhesive resins, the elastic modulus of CSE2 was significantly higher than that of CSE before and after water immersion (p < 0.001), and the water sorption of CSE was higher than that of CSE2. CONCLUSIONS The higher DC of adhesive resins of two-step self-etch adhesives resists water aging and improves the initial bond strengths and durability of the resin-dentin bond.","PeriodicalId":94234,"journal":{"name":"The journal of adhesive dentistry","volume":"22 1","pages":"31-37"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"42","resultStr":"{\"title\":\"Dentin Bonding Durability of Two-step Self-etch Adhesives with Improved of Degree of Conversion of Adhesive Resins.\",\"authors\":\"Kento Sato, K. Hosaka, Masahiro Takahashi, M. Ikeda, F. Tian, W. Komada, M. Nakajima, R. Foxton, Y. Nishitani, D. Pashley, J. Tagami\",\"doi\":\"10.3290/j.jad.a37726\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PURPOSE To evaluate (1) the initial and long-term microtensile bond strengths of two-step self-etch adhesives with different degrees of conversion (DC); (2) the elastic modulus of the respective adhesive resins; (3) the water sorption of the respective adhesive resins. MATERIALS AND METHODS Two two-step self-etch adhesives, Clearfil SE Bond (CSE) and Clearfil SE Bond 2 (CSE2) were used in this study. The DC was determined using ATR/FT-IR with a time-based spectrum analysis. Midcoronal flat dentin surfaces of 24 human molars were prepared with 600-grit SiC paper for microtensile bond strength (µTBS) testing. CSE and CSE2 were applied to the dentin surfaces according to the manufacturer's instructions, followed by composite buildups. The µTBS was measured after water storage for 24 h, 6 months, and 1 year. The elastic modulus (before and after 1 month of water immersion) was determined by the three-point flexural bending test and water sorption values by the water sorption test. RESULTS CSE2 showed significantly higher DC than CSE. The µTBS of CSE2 was significantly higher than that of CSE in all water storage periods. One-year water storage decreased the µTBS of CSE; however, it did not decrease that of CSE2. Regarding the polymerized adhesive resins, the elastic modulus of CSE2 was significantly higher than that of CSE before and after water immersion (p < 0.001), and the water sorption of CSE was higher than that of CSE2. CONCLUSIONS The higher DC of adhesive resins of two-step self-etch adhesives resists water aging and improves the initial bond strengths and durability of the resin-dentin bond.\",\"PeriodicalId\":94234,\"journal\":{\"name\":\"The journal of adhesive dentistry\",\"volume\":\"22 1\",\"pages\":\"31-37\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"42\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The journal of adhesive dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3290/j.jad.a37726\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The journal of adhesive dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3290/j.jad.a37726","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 42

摘要

目的评价(1)不同转化度的两步自蚀刻胶粘剂(DC)的初始和长期微拉伸粘结强度;(2)所粘接树脂的弹性模量;(3)各自胶粘剂树脂的吸水性。材料与方法采用Clearfil SE Bond (CSE)和Clearfil SE Bond 2 (CSE2)两种两步自蚀刻胶粘剂。使用ATR/FT-IR和基于时间的光谱分析来确定DC。采用600粒度SiC纸制备24颗人磨牙中冠牙本质平面,进行微拉伸粘结强度(µTBS)测试。根据制造商的说明将CSE和CSE2应用于牙本质表面,然后进行复合堆积。在水储存24小时、6个月和1年后测量µTBS。弹性模量(浸水1个月前和1个月后)通过三点弯曲试验确定,吸水值通过吸水试验确定。结果scse2的DC明显高于CSE。在所有蓄水期,CSE2的µTBS均显著高于CSE。1年的水储存降低了CSE的µTBS;但对CSE2的影响不明显。对于聚合胶粘剂树脂,CSE2的弹性模量显著高于CSE2浸泡前后的弹性模量(p < 0.001),且CSE2的吸水性高于CSE2。结论两步自蚀刻胶粘剂具有较高的粘接树脂DC,抗水老化,提高了树脂-牙本质的初始粘接强度和耐久性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dentin Bonding Durability of Two-step Self-etch Adhesives with Improved of Degree of Conversion of Adhesive Resins.
PURPOSE To evaluate (1) the initial and long-term microtensile bond strengths of two-step self-etch adhesives with different degrees of conversion (DC); (2) the elastic modulus of the respective adhesive resins; (3) the water sorption of the respective adhesive resins. MATERIALS AND METHODS Two two-step self-etch adhesives, Clearfil SE Bond (CSE) and Clearfil SE Bond 2 (CSE2) were used in this study. The DC was determined using ATR/FT-IR with a time-based spectrum analysis. Midcoronal flat dentin surfaces of 24 human molars were prepared with 600-grit SiC paper for microtensile bond strength (µTBS) testing. CSE and CSE2 were applied to the dentin surfaces according to the manufacturer's instructions, followed by composite buildups. The µTBS was measured after water storage for 24 h, 6 months, and 1 year. The elastic modulus (before and after 1 month of water immersion) was determined by the three-point flexural bending test and water sorption values by the water sorption test. RESULTS CSE2 showed significantly higher DC than CSE. The µTBS of CSE2 was significantly higher than that of CSE in all water storage periods. One-year water storage decreased the µTBS of CSE; however, it did not decrease that of CSE2. Regarding the polymerized adhesive resins, the elastic modulus of CSE2 was significantly higher than that of CSE before and after water immersion (p < 0.001), and the water sorption of CSE was higher than that of CSE2. CONCLUSIONS The higher DC of adhesive resins of two-step self-etch adhesives resists water aging and improves the initial bond strengths and durability of the resin-dentin bond.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Long-term Survival Rate and Clinical Quality of Individually Layered Indirect Composite Restorations in Adolescents and Young Adults. A Novel Graphite Fluoride/Bioactive Glass-containing Orthodontic Primer with Antibacterial and Remineralization Properties: An In-vitro Study. Can Orthodontic Adhesive Systems Inhibit the Formation and Development of White Spot Lesions During Fixed Orthodontic Treatment? A Systematic Review. Morphological Analysis and Bond Strength to Root Canal Dentin of Endodontically Treated and Retreated Teeth: An Ex Vivo Study. Three-Dimensional Internal Voids and Marginal Adaptation in Deep Margin Elevation Technique: Efficiency of Highly Filled Flowable Composites.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1