蜘蛛臂渐晕对变形镜干涉测量的影响

IF 1.7 3区 工程技术 Q2 ENGINEERING, AEROSPACE Journal of Astronomical Telescopes Instruments and Systems Pub Date : 2023-04-01 DOI:10.1117/1.JATIS.9.2.029002
R. Briguglio, G. Pariani, M. Xompero, Nicolò Azzaroli, C. Selmi, A. Riccardi, L. Oggioni
{"title":"蜘蛛臂渐晕对变形镜干涉测量的影响","authors":"R. Briguglio, G. Pariani, M. Xompero, Nicolò Azzaroli, C. Selmi, A. Riccardi, L. Oggioni","doi":"10.1117/1.JATIS.9.2.029002","DOIUrl":null,"url":null,"abstract":"Abstract. The interferometric calibration and measurement of deformable mirrors for adaptive optics are often performed on complex optical system with spider arms. The spider shadows may divide the mirror surface into separate islands on the detector, so the interferometer fails in reconnecting them to a common phase value. The calibration measurements then suffer from such artificial differential pistons across islands, which is converted into a wrong actuator command and in general into a poor calibration. We review the effects of spider arms shadowing as experienced during the optical calibration of large format adaptive mirrors, such as the Large Binocular Telescope and Very Large Telescope ones; we describe the procedures that we tested to cope with these issues and their effectiveness; and we present a laboratory assessment of the effect of such a shadowing with a dedicated test setup. Our work is part of a preparatory activity for the optical test of the European Extremely Large Telescope adaptive mirror M4.","PeriodicalId":54342,"journal":{"name":"Journal of Astronomical Telescopes Instruments and Systems","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On the effects of spider-arms vignetting on interferometric measurements of deformable mirrors\",\"authors\":\"R. Briguglio, G. Pariani, M. Xompero, Nicolò Azzaroli, C. Selmi, A. Riccardi, L. Oggioni\",\"doi\":\"10.1117/1.JATIS.9.2.029002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract. The interferometric calibration and measurement of deformable mirrors for adaptive optics are often performed on complex optical system with spider arms. The spider shadows may divide the mirror surface into separate islands on the detector, so the interferometer fails in reconnecting them to a common phase value. The calibration measurements then suffer from such artificial differential pistons across islands, which is converted into a wrong actuator command and in general into a poor calibration. We review the effects of spider arms shadowing as experienced during the optical calibration of large format adaptive mirrors, such as the Large Binocular Telescope and Very Large Telescope ones; we describe the procedures that we tested to cope with these issues and their effectiveness; and we present a laboratory assessment of the effect of such a shadowing with a dedicated test setup. Our work is part of a preparatory activity for the optical test of the European Extremely Large Telescope adaptive mirror M4.\",\"PeriodicalId\":54342,\"journal\":{\"name\":\"Journal of Astronomical Telescopes Instruments and Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Astronomical Telescopes Instruments and Systems\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1117/1.JATIS.9.2.029002\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, AEROSPACE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Astronomical Telescopes Instruments and Systems","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1117/1.JATIS.9.2.029002","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, AEROSPACE","Score":null,"Total":0}
引用次数: 0

摘要

摘要自适应光学中变形镜的干涉定标和测量经常在复杂的蜘蛛臂光学系统中进行。蜘蛛影可能会将探测器上的镜面分割成独立的岛屿,因此干涉仪无法将它们重新连接到一个共同的相位值。校准测量结果会受到岛屿上的人工差速活塞的影响,这些差速活塞会转换成错误的执行器命令,从而导致校准结果不佳。本文综述了大口径自适应镜(如大双筒望远镜和甚大望远镜)在光学校准过程中所经历的蜘蛛臂阴影效应;我们描述了我们为处理这些问题而测试的程序及其有效性;我们提出了一个实验室评估的效果,这种阴影与专门的测试设置。我们的工作是欧洲超大望远镜M4自适应反射镜光学测试准备活动的一部分。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
On the effects of spider-arms vignetting on interferometric measurements of deformable mirrors
Abstract. The interferometric calibration and measurement of deformable mirrors for adaptive optics are often performed on complex optical system with spider arms. The spider shadows may divide the mirror surface into separate islands on the detector, so the interferometer fails in reconnecting them to a common phase value. The calibration measurements then suffer from such artificial differential pistons across islands, which is converted into a wrong actuator command and in general into a poor calibration. We review the effects of spider arms shadowing as experienced during the optical calibration of large format adaptive mirrors, such as the Large Binocular Telescope and Very Large Telescope ones; we describe the procedures that we tested to cope with these issues and their effectiveness; and we present a laboratory assessment of the effect of such a shadowing with a dedicated test setup. Our work is part of a preparatory activity for the optical test of the European Extremely Large Telescope adaptive mirror M4.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.40
自引率
13.00%
发文量
119
期刊介绍: The Journal of Astronomical Telescopes, Instruments, and Systems publishes peer-reviewed papers reporting on original research in the development, testing, and application of telescopes, instrumentation, techniques, and systems for ground- and space-based astronomy.
期刊最新文献
Design, implementation, and performance of the primary reflector for SALTUS Solar system science with the Single Aperture Large Telescope for Universe Studies space observatory Milky Way and nearby galaxy science with the SALTUS space observatory Adjustable X-ray optics: thin-film actuator measurement and figure correction performance FIREBall-2 UV balloon telescope in-flight calibration system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1