Maycon Crispim de Oliveira Carvalho, A. B. Fernandes, H. C. Carvalho, R. Zângaro, Carlos José de Lima
{"title":"基于臭氧化水水动力学模型的结肠镜消毒后处理系统的初步研究","authors":"Maycon Crispim de Oliveira Carvalho, A. B. Fernandes, H. C. Carvalho, R. Zângaro, Carlos José de Lima","doi":"10.1080/01919512.2022.2164251","DOIUrl":null,"url":null,"abstract":"ABSTRACT Endoscopes are flexible medical instruments that require a high-level disinfection protocol. This study aimed to develop a fluid-dynamic system with ozonated water to obtain high-level disinfection. A colonoscope replica with an internal flexible polytetrafluoroethylene (PTFE) tube was made. The set was then contaminated, washed, and disinfected with ozonated water. The replica was placed in a tank with a fluid-dynamic circuit. The endoscope was submerged into the tank and ozonated water was pumped through the working channel. Quantitative microbiological tests were carried out between the washing stage and disinfection in the fluid-dynamic system with ozonated water. The results indicated that the ozone concentration curve in the water from the 27- liter main tank reached the value of 0.95 mg/L after 20 minutes. No bacterial growth was detected after the replica remained in the hydrodynamic system with ozonated water for 15 minutes. The results showed that the fluid-dynamic system using ozonated water is promising as it enables high-level disinfection of the colonoscope.","PeriodicalId":19580,"journal":{"name":"Ozone: Science & Engineering","volume":"121 1","pages":"419 - 430"},"PeriodicalIF":2.1000,"publicationDate":"2023-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Preliminary Study: Disinfection of Colonoscope Using a Reprocessing System Based on a Hydrodynamic Model with Ozonated Water\",\"authors\":\"Maycon Crispim de Oliveira Carvalho, A. B. Fernandes, H. C. Carvalho, R. Zângaro, Carlos José de Lima\",\"doi\":\"10.1080/01919512.2022.2164251\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Endoscopes are flexible medical instruments that require a high-level disinfection protocol. This study aimed to develop a fluid-dynamic system with ozonated water to obtain high-level disinfection. A colonoscope replica with an internal flexible polytetrafluoroethylene (PTFE) tube was made. The set was then contaminated, washed, and disinfected with ozonated water. The replica was placed in a tank with a fluid-dynamic circuit. The endoscope was submerged into the tank and ozonated water was pumped through the working channel. Quantitative microbiological tests were carried out between the washing stage and disinfection in the fluid-dynamic system with ozonated water. The results indicated that the ozone concentration curve in the water from the 27- liter main tank reached the value of 0.95 mg/L after 20 minutes. No bacterial growth was detected after the replica remained in the hydrodynamic system with ozonated water for 15 minutes. The results showed that the fluid-dynamic system using ozonated water is promising as it enables high-level disinfection of the colonoscope.\",\"PeriodicalId\":19580,\"journal\":{\"name\":\"Ozone: Science & Engineering\",\"volume\":\"121 1\",\"pages\":\"419 - 430\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-01-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ozone: Science & Engineering\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1080/01919512.2022.2164251\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ENVIRONMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ozone: Science & Engineering","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1080/01919512.2022.2164251","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
Preliminary Study: Disinfection of Colonoscope Using a Reprocessing System Based on a Hydrodynamic Model with Ozonated Water
ABSTRACT Endoscopes are flexible medical instruments that require a high-level disinfection protocol. This study aimed to develop a fluid-dynamic system with ozonated water to obtain high-level disinfection. A colonoscope replica with an internal flexible polytetrafluoroethylene (PTFE) tube was made. The set was then contaminated, washed, and disinfected with ozonated water. The replica was placed in a tank with a fluid-dynamic circuit. The endoscope was submerged into the tank and ozonated water was pumped through the working channel. Quantitative microbiological tests were carried out between the washing stage and disinfection in the fluid-dynamic system with ozonated water. The results indicated that the ozone concentration curve in the water from the 27- liter main tank reached the value of 0.95 mg/L after 20 minutes. No bacterial growth was detected after the replica remained in the hydrodynamic system with ozonated water for 15 minutes. The results showed that the fluid-dynamic system using ozonated water is promising as it enables high-level disinfection of the colonoscope.
期刊介绍:
The only journal in the world that focuses on the technologies of ozone and related oxidation technologies, Ozone: Science and Engineering brings you quality original research, review papers, research notes, and case histories in each issue. Get the most up-to date results of basic, applied, and engineered research including:
-Ozone generation and contacting-
Treatment of drinking water-
Analysis of ozone in gases and liquids-
Treatment of wastewater and hazardous waste-
Advanced oxidation processes-
Treatment of emerging contaminants-
Agri-Food applications-
Process control of ozone systems-
New applications for ozone (e.g. laundry applications, semiconductor applications)-
Chemical synthesis.
All submitted manuscripts are subject to initial appraisal by the Editor, and, if found suitable for further consideration, to peer review by independent, anonymous expert referees.