镰状细胞病早期诊断的新型免疫分析法即时检测的分析特点和性能

C. Jaja, J. Edem-Hotah, J. Shepherd, N. Patel, Hongyan Xu, R. Gibson
{"title":"镰状细胞病早期诊断的新型免疫分析法即时检测的分析特点和性能","authors":"C. Jaja, J. Edem-Hotah, J. Shepherd, N. Patel, Hongyan Xu, R. Gibson","doi":"10.1097/POC.0000000000000210","DOIUrl":null,"url":null,"abstract":"Abstract Microtechnology point-of-care tests (POCTs), which are accurate and easy to use, are needed for the diagnosis of infants with sickle cell disease (SCD) to facilitate linkage to early care and management in resource-constrained public health centers in sub-Saharan Africa. We systematically reviewed the evidence of 2 novel POCTs' characteristics, performance, and clinical utility compared with standard laboratory-based methods. Studies evaluating the use of POCTs for SCD screening were identified by a search of PubMed and CINAHL. Eighty-four abstracts were screened, and 68 full-text articles were assessed, of which 12 met the inclusion criteria. Twelve studies conducted in 10 countries evaluated performance and diagnostic accuracy of 2 qualitative immunoassay POCTs (Sickle SCAN and HemoTypeSC). Eight studies were field reviews that compared the performance of the POCTs to extant laboratory methods, and one study reported on clinical management of SCD. The studies of diagnostic accuracy showed excellent performance for immunoassay POCTs. The reported correlation between criterion standard comparator laboratory-based assays was high across the 2 POCTs. Specificity for both POCTs was excellent among newborns and infants even in the presence of high fetal hemoglobin levels. The POCTs were deemed easy to use and had rapid turnaround times. The performance of immunoassay SCD-POCTs is comparable to reference assays, and the SCD-POCTs have the potential to improve patient outcomes. Additional studies on clinical utility, implementation, and accessibility are needed. Future research should focus on understanding and mapping the barriers to implementation within the context of resource-constrained settings.","PeriodicalId":20262,"journal":{"name":"Point of Care: The Journal of Near-Patient Testing & Technology","volume":"94 8 1","pages":"84 - 94"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Analytic Characteristics and Performance of Novel Immunoassay Point-of-Care Tests for Early Diagnosis of Sickle Cell Disease\",\"authors\":\"C. Jaja, J. Edem-Hotah, J. Shepherd, N. Patel, Hongyan Xu, R. Gibson\",\"doi\":\"10.1097/POC.0000000000000210\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Microtechnology point-of-care tests (POCTs), which are accurate and easy to use, are needed for the diagnosis of infants with sickle cell disease (SCD) to facilitate linkage to early care and management in resource-constrained public health centers in sub-Saharan Africa. We systematically reviewed the evidence of 2 novel POCTs' characteristics, performance, and clinical utility compared with standard laboratory-based methods. Studies evaluating the use of POCTs for SCD screening were identified by a search of PubMed and CINAHL. Eighty-four abstracts were screened, and 68 full-text articles were assessed, of which 12 met the inclusion criteria. Twelve studies conducted in 10 countries evaluated performance and diagnostic accuracy of 2 qualitative immunoassay POCTs (Sickle SCAN and HemoTypeSC). Eight studies were field reviews that compared the performance of the POCTs to extant laboratory methods, and one study reported on clinical management of SCD. The studies of diagnostic accuracy showed excellent performance for immunoassay POCTs. The reported correlation between criterion standard comparator laboratory-based assays was high across the 2 POCTs. Specificity for both POCTs was excellent among newborns and infants even in the presence of high fetal hemoglobin levels. The POCTs were deemed easy to use and had rapid turnaround times. The performance of immunoassay SCD-POCTs is comparable to reference assays, and the SCD-POCTs have the potential to improve patient outcomes. Additional studies on clinical utility, implementation, and accessibility are needed. Future research should focus on understanding and mapping the barriers to implementation within the context of resource-constrained settings.\",\"PeriodicalId\":20262,\"journal\":{\"name\":\"Point of Care: The Journal of Near-Patient Testing & Technology\",\"volume\":\"94 8 1\",\"pages\":\"84 - 94\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Point of Care: The Journal of Near-Patient Testing & Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/POC.0000000000000210\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Point of Care: The Journal of Near-Patient Testing & Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/POC.0000000000000210","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在撒哈拉以南非洲资源有限的公共卫生中心,精确且易于使用的微技术即时检测(POCTs)是诊断婴儿镰状细胞病(SCD)的必要手段,以促进与早期护理和管理的联系。我们系统地回顾了两种新型POCTs的特征、性能和临床应用的证据,并与标准的实验室方法进行了比较。通过PubMed和CINAHL的检索确定了评估POCTs用于SCD筛查的研究。筛选了84篇摘要,评估了68篇全文文章,其中12篇符合纳入标准。在10个国家进行的12项研究评估了2种定性免疫测定POCTs(镰状扫描和血型分析)的性能和诊断准确性。八项研究是现场综述,比较了poct与现有实验室方法的性能,一项研究报告了SCD的临床管理。诊断准确性的研究显示免疫测定POCTs具有优异的性能。在2个POCTs中,报告的标准标准比较器实验室检测之间的相关性很高。在新生儿和婴儿中,即使存在高胎儿血红蛋白水平,POCTs的特异性也很好。poct被认为易于使用,周转时间短。免疫分析SCD-POCTs的性能与参考分析相当,并且SCD-POCTs具有改善患者预后的潜力。需要对临床应用、实施和可及性进行进一步的研究。未来的研究应侧重于了解和绘制资源受限环境下实施的障碍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analytic Characteristics and Performance of Novel Immunoassay Point-of-Care Tests for Early Diagnosis of Sickle Cell Disease
Abstract Microtechnology point-of-care tests (POCTs), which are accurate and easy to use, are needed for the diagnosis of infants with sickle cell disease (SCD) to facilitate linkage to early care and management in resource-constrained public health centers in sub-Saharan Africa. We systematically reviewed the evidence of 2 novel POCTs' characteristics, performance, and clinical utility compared with standard laboratory-based methods. Studies evaluating the use of POCTs for SCD screening were identified by a search of PubMed and CINAHL. Eighty-four abstracts were screened, and 68 full-text articles were assessed, of which 12 met the inclusion criteria. Twelve studies conducted in 10 countries evaluated performance and diagnostic accuracy of 2 qualitative immunoassay POCTs (Sickle SCAN and HemoTypeSC). Eight studies were field reviews that compared the performance of the POCTs to extant laboratory methods, and one study reported on clinical management of SCD. The studies of diagnostic accuracy showed excellent performance for immunoassay POCTs. The reported correlation between criterion standard comparator laboratory-based assays was high across the 2 POCTs. Specificity for both POCTs was excellent among newborns and infants even in the presence of high fetal hemoglobin levels. The POCTs were deemed easy to use and had rapid turnaround times. The performance of immunoassay SCD-POCTs is comparable to reference assays, and the SCD-POCTs have the potential to improve patient outcomes. Additional studies on clinical utility, implementation, and accessibility are needed. Future research should focus on understanding and mapping the barriers to implementation within the context of resource-constrained settings.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Comparison of International Normalized Ratio Results by Point-of-Care Device and Clinical Laboratory Analyzers in a Vascular Surgery Department Point-of-Care Testing in Hypercoagulable Conditions Managed With Warfarin Critical Care Nurses' Views and Experiences of Preanalytical Factors Influencing Point-of-Care Testing Rapid Assessment of Coagulation at the Point of Care With the Hemochron Signature Elite System Invited Product Profile: Detecting Antibodies for Lyme Disease at the Point of Care
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1