土耳其,Muğla,历史遗迹的行人风和室内热舒适数值评价

IF 1.5 4区 经济学 0 ARCHITECTURE Open House International Pub Date : 2022-06-07 DOI:10.1108/ohi-12-2021-0284
Funda Gençer, I. Karadag
{"title":"土耳其,Muğla,历史遗迹的行人风和室内热舒适数值评价","authors":"Funda Gençer, I. Karadag","doi":"10.1108/ohi-12-2021-0284","DOIUrl":null,"url":null,"abstract":"PurposeThe study aims to analyze both thermal and wind comfort conditions of a historical mosque's interior and outdoor spaces for the planning of further conservation decisions.Design/methodology/approachThe method is composed of two steps. First, thermal comfort analyses are conducted via Design-Builder Software. The predicted mean vote (PMV) and predicted percentage of dissatisfied indices were calculated and evaluated using the ASHRAE 55–2010 standard. Thermal comfort conditions are analyzed with the proposed three operations. Second, wind comfort analyses are conducted via computational fluid dynamics (CFD) software. Outdoor thermal comfort conditions are predicted by air temperature, mean radiant temperature, wind speed and relative humidity.FindingsThe (PMV) in the harim was calculated as −1.83 (cool) which corresponds to a predicted percentage of dissatisfaction (PPD) equal to 68.54%. Thermal comfort was provided by daytime and continuous operations; however, intermittent operations did not provide thermal comfort. The wind velocities around the mosque are well below the 5 m/s limit value for standing defined by NEN 8100 wind nuisance standard. Moreover, the limit value of 2.5 m/s for sitting was also satisfied with more than 80% of the semi-enclosed area around the entrance of the mosque. Last comer's hall remains in a slight cold stress range, the rest of the areas have no thermal stress.Originality/valueThis two-stage study creates a base for further improvements to provide comfort conditions in a historical building without interfering with its original features.","PeriodicalId":44969,"journal":{"name":"Open House International","volume":"10 3 1","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2022-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Numerical evaluation of pedestrian-level wind and indoor thermal comfort of a historical monument, Muğla, Turkey\",\"authors\":\"Funda Gençer, I. Karadag\",\"doi\":\"10.1108/ohi-12-2021-0284\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PurposeThe study aims to analyze both thermal and wind comfort conditions of a historical mosque's interior and outdoor spaces for the planning of further conservation decisions.Design/methodology/approachThe method is composed of two steps. First, thermal comfort analyses are conducted via Design-Builder Software. The predicted mean vote (PMV) and predicted percentage of dissatisfied indices were calculated and evaluated using the ASHRAE 55–2010 standard. Thermal comfort conditions are analyzed with the proposed three operations. Second, wind comfort analyses are conducted via computational fluid dynamics (CFD) software. Outdoor thermal comfort conditions are predicted by air temperature, mean radiant temperature, wind speed and relative humidity.FindingsThe (PMV) in the harim was calculated as −1.83 (cool) which corresponds to a predicted percentage of dissatisfaction (PPD) equal to 68.54%. Thermal comfort was provided by daytime and continuous operations; however, intermittent operations did not provide thermal comfort. The wind velocities around the mosque are well below the 5 m/s limit value for standing defined by NEN 8100 wind nuisance standard. Moreover, the limit value of 2.5 m/s for sitting was also satisfied with more than 80% of the semi-enclosed area around the entrance of the mosque. Last comer's hall remains in a slight cold stress range, the rest of the areas have no thermal stress.Originality/valueThis two-stage study creates a base for further improvements to provide comfort conditions in a historical building without interfering with its original features.\",\"PeriodicalId\":44969,\"journal\":{\"name\":\"Open House International\",\"volume\":\"10 3 1\",\"pages\":\"\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2022-06-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open House International\",\"FirstCategoryId\":\"96\",\"ListUrlMain\":\"https://doi.org/10.1108/ohi-12-2021-0284\",\"RegionNum\":4,\"RegionCategory\":\"经济学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"0\",\"JCRName\":\"ARCHITECTURE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open House International","FirstCategoryId":"96","ListUrlMain":"https://doi.org/10.1108/ohi-12-2021-0284","RegionNum":4,"RegionCategory":"经济学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"ARCHITECTURE","Score":null,"Total":0}
引用次数: 1

摘要

本研究旨在分析一座历史悠久的清真寺室内外空间的热舒适和风舒适条件,为进一步的保护决策提供规划。设计/方法/方法该方法由两步组成。首先,通过Design-Builder软件进行热舒适分析。预测平均投票(PMV)和预测不满意指数百分比采用ASHRAE 55-2010标准进行计算和评价。根据提出的三种操作方法,对热舒适条件进行了分析。其次,通过计算流体力学(CFD)软件进行风舒适性分析。通过空气温度、平均辐射温度、风速和相对湿度对室外热舒适条件进行预测。研究结果:研究对象的PMV值为- 1.83 (cool),对应于预测的不满率(PPD)为68.54%。白天和连续运行提供热舒适;然而,间歇性操作不能提供热舒适。清真寺周围的风速远低于NEN 8100风力滋扰标准规定的5米/秒限值。此外,2.5 m/s的坐姿限值也满足清真寺入口周围80%以上的半封闭区域。最后一个角落的大厅保持在轻微的冷应力范围内,其余区域没有热应力。原创性/价值这项分为两个阶段的研究为进一步改善历史建筑奠定基础,在不影响其原有特色的情况下,为其提供舒适的环境。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Numerical evaluation of pedestrian-level wind and indoor thermal comfort of a historical monument, Muğla, Turkey
PurposeThe study aims to analyze both thermal and wind comfort conditions of a historical mosque's interior and outdoor spaces for the planning of further conservation decisions.Design/methodology/approachThe method is composed of two steps. First, thermal comfort analyses are conducted via Design-Builder Software. The predicted mean vote (PMV) and predicted percentage of dissatisfied indices were calculated and evaluated using the ASHRAE 55–2010 standard. Thermal comfort conditions are analyzed with the proposed three operations. Second, wind comfort analyses are conducted via computational fluid dynamics (CFD) software. Outdoor thermal comfort conditions are predicted by air temperature, mean radiant temperature, wind speed and relative humidity.FindingsThe (PMV) in the harim was calculated as −1.83 (cool) which corresponds to a predicted percentage of dissatisfaction (PPD) equal to 68.54%. Thermal comfort was provided by daytime and continuous operations; however, intermittent operations did not provide thermal comfort. The wind velocities around the mosque are well below the 5 m/s limit value for standing defined by NEN 8100 wind nuisance standard. Moreover, the limit value of 2.5 m/s for sitting was also satisfied with more than 80% of the semi-enclosed area around the entrance of the mosque. Last comer's hall remains in a slight cold stress range, the rest of the areas have no thermal stress.Originality/valueThis two-stage study creates a base for further improvements to provide comfort conditions in a historical building without interfering with its original features.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
18.20%
发文量
48
期刊介绍: The journal of an association of institues and individuals concerned with housing, design and development in the built environment. Theories, tools and pratice with special emphasis on the local scale.
期刊最新文献
Analysis of earthquake resilience factors for buildings: the case of Istanbul high-rise buildings Geometric analysis of early Ottoman tombs within the context of conservation studies Public participation in the social sustainability evaluation of smart city infrastructure in the context of big data: a critical review Teaching parametric design: fostering algorithmic thinking through incomplete recipes Spatial accessibility dynamics of urban parks in Nanjing, China: implications for spatial equity
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1