Adityakrisna Yoshi Putra Wigianto, Y. Ishida, Takashi Matsuda, T. Goto, Megumi Watanabe, T. Ichikawa
{"title":"采用高频热处理和冲压技术制造的新型磁性附着系统:介绍及基本性能","authors":"Adityakrisna Yoshi Putra Wigianto, Y. Ishida, Takashi Matsuda, T. Goto, Megumi Watanabe, T. Ichikawa","doi":"10.3390/dj10050075","DOIUrl":null,"url":null,"abstract":"Recently, a novel magnetic attachment with extremely low cost and high performance was developed. This article aims to introduce a novel magnetic attachment and to evaluate its basic eligibility for denture retention in clinical practice. The novel magnetic attachment system used in this study was the direct-bonding root-keeper-type Magteeth™ MT800 (MagneDesign, Nagoya, Japan). The retentive force without displacement (position 0) and after horizontal displacement to positions 0.5, 1, 1.5, 2, 2.5, and 3 mm were measured. The values relative to the retentive force without displacement were gradually decreased to 82.7 ± 16.3%, 68.8 ± 17.1%, 62.4 ± 15%, 47.2 ± 13.1%, 35.7 ± 9.9%, and 20.7 ± 6.5%, respectively. The retentive force and magnetic field strength did not change significantly after the load test (100 N load, 10,000 times). No new gap between the metal and resin was found in the root keeper- and magnet assembly-embedded blocks after the load test. Some scratches on magnetic assembly and root keeper surface, while no change in the resin texture after the load test were observed. Based on the findings of this preliminary study, this novel low-cost magnetic attachment exhibited favorable retention, strength, and durability for clinical use.","PeriodicalId":47284,"journal":{"name":"Open Dentistry Journal","volume":"52 1","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Novel Magnetic Attachment System Manufactured Using High-Frequency Heat Treatment and Stamp Technique: Introduction and Basic Performance\",\"authors\":\"Adityakrisna Yoshi Putra Wigianto, Y. Ishida, Takashi Matsuda, T. Goto, Megumi Watanabe, T. Ichikawa\",\"doi\":\"10.3390/dj10050075\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, a novel magnetic attachment with extremely low cost and high performance was developed. This article aims to introduce a novel magnetic attachment and to evaluate its basic eligibility for denture retention in clinical practice. The novel magnetic attachment system used in this study was the direct-bonding root-keeper-type Magteeth™ MT800 (MagneDesign, Nagoya, Japan). The retentive force without displacement (position 0) and after horizontal displacement to positions 0.5, 1, 1.5, 2, 2.5, and 3 mm were measured. The values relative to the retentive force without displacement were gradually decreased to 82.7 ± 16.3%, 68.8 ± 17.1%, 62.4 ± 15%, 47.2 ± 13.1%, 35.7 ± 9.9%, and 20.7 ± 6.5%, respectively. The retentive force and magnetic field strength did not change significantly after the load test (100 N load, 10,000 times). No new gap between the metal and resin was found in the root keeper- and magnet assembly-embedded blocks after the load test. Some scratches on magnetic assembly and root keeper surface, while no change in the resin texture after the load test were observed. Based on the findings of this preliminary study, this novel low-cost magnetic attachment exhibited favorable retention, strength, and durability for clinical use.\",\"PeriodicalId\":47284,\"journal\":{\"name\":\"Open Dentistry Journal\",\"volume\":\"52 1\",\"pages\":\"\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2022-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open Dentistry Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/dj10050075\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj10050075","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Novel Magnetic Attachment System Manufactured Using High-Frequency Heat Treatment and Stamp Technique: Introduction and Basic Performance
Recently, a novel magnetic attachment with extremely low cost and high performance was developed. This article aims to introduce a novel magnetic attachment and to evaluate its basic eligibility for denture retention in clinical practice. The novel magnetic attachment system used in this study was the direct-bonding root-keeper-type Magteeth™ MT800 (MagneDesign, Nagoya, Japan). The retentive force without displacement (position 0) and after horizontal displacement to positions 0.5, 1, 1.5, 2, 2.5, and 3 mm were measured. The values relative to the retentive force without displacement were gradually decreased to 82.7 ± 16.3%, 68.8 ± 17.1%, 62.4 ± 15%, 47.2 ± 13.1%, 35.7 ± 9.9%, and 20.7 ± 6.5%, respectively. The retentive force and magnetic field strength did not change significantly after the load test (100 N load, 10,000 times). No new gap between the metal and resin was found in the root keeper- and magnet assembly-embedded blocks after the load test. Some scratches on magnetic assembly and root keeper surface, while no change in the resin texture after the load test were observed. Based on the findings of this preliminary study, this novel low-cost magnetic attachment exhibited favorable retention, strength, and durability for clinical use.