{"title":"稳定性指示反相高效液相色谱法同时测定注射用无菌散中头孢曲松和他唑巴坦的含量","authors":"T. Vimalakkannan, P. Parveen, Salomi, K. Reddy","doi":"10.33974/ijrpca.v1i2.62","DOIUrl":null,"url":null,"abstract":"A simple, rapid, precise and accurate method is developed for the quantitative simultaneous determination of ceftriaxone and tazobactum in bulk and pharmaceutical formulations. Separation of ceftriaxone and tazobactum was successfully achieved by using Inertsil C18 ODS column 250X4.6mm, 5µm in an isocratic mode using water and acetonitrile (80:20) at a flow rate of 1.0 ml/min and was monitored at 254 nm with a retention time of 3.049 minutes and 4.317 minutes for ceftriaxone and tazobactum respectively. The method was validated and the response was found to be linear in the drug concentration range of 20µg/ml to 80 µg/ml for ceftriaxone and 5 µg/ml to 35 µg/ml for tazobactum. The values of the correlation coefficient were found to be 0.999 for ceftriaxone and 0.999 for tazobactum respectively. The LOD and LOQ for ceftriaxone were found to be 0.021 and 0.064 respectively. The LOD and LOQ for tazobactum were found to be 0.030 and 0.091 respectively. The percentage recovery for ceftriaxone and tazobactum were found to be 98-102% respectively which indicates that the proposed method is highly accurate. The specificity of the method shows good correlation between retention times of standard with the sample. The method was extensively validated according to ICH guidelines for Linearity, Accuracy, Precision, Specificity and Robustness. Stability of the drugs was determined by using acid/base, thermal, oxidative stress testing.","PeriodicalId":14207,"journal":{"name":"International Journal of Research In Pharmaceutical Chemistry and Analysis","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Stability indicating RP-HPLC method development and validation for the simultaneous estimation of ceftriaxone and tazobactum in sterile powder for injection\",\"authors\":\"T. Vimalakkannan, P. Parveen, Salomi, K. Reddy\",\"doi\":\"10.33974/ijrpca.v1i2.62\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A simple, rapid, precise and accurate method is developed for the quantitative simultaneous determination of ceftriaxone and tazobactum in bulk and pharmaceutical formulations. Separation of ceftriaxone and tazobactum was successfully achieved by using Inertsil C18 ODS column 250X4.6mm, 5µm in an isocratic mode using water and acetonitrile (80:20) at a flow rate of 1.0 ml/min and was monitored at 254 nm with a retention time of 3.049 minutes and 4.317 minutes for ceftriaxone and tazobactum respectively. The method was validated and the response was found to be linear in the drug concentration range of 20µg/ml to 80 µg/ml for ceftriaxone and 5 µg/ml to 35 µg/ml for tazobactum. The values of the correlation coefficient were found to be 0.999 for ceftriaxone and 0.999 for tazobactum respectively. The LOD and LOQ for ceftriaxone were found to be 0.021 and 0.064 respectively. The LOD and LOQ for tazobactum were found to be 0.030 and 0.091 respectively. The percentage recovery for ceftriaxone and tazobactum were found to be 98-102% respectively which indicates that the proposed method is highly accurate. The specificity of the method shows good correlation between retention times of standard with the sample. The method was extensively validated according to ICH guidelines for Linearity, Accuracy, Precision, Specificity and Robustness. Stability of the drugs was determined by using acid/base, thermal, oxidative stress testing.\",\"PeriodicalId\":14207,\"journal\":{\"name\":\"International Journal of Research In Pharmaceutical Chemistry and Analysis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-04-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Research In Pharmaceutical Chemistry and Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33974/ijrpca.v1i2.62\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Research In Pharmaceutical Chemistry and Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33974/ijrpca.v1i2.62","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Stability indicating RP-HPLC method development and validation for the simultaneous estimation of ceftriaxone and tazobactum in sterile powder for injection
A simple, rapid, precise and accurate method is developed for the quantitative simultaneous determination of ceftriaxone and tazobactum in bulk and pharmaceutical formulations. Separation of ceftriaxone and tazobactum was successfully achieved by using Inertsil C18 ODS column 250X4.6mm, 5µm in an isocratic mode using water and acetonitrile (80:20) at a flow rate of 1.0 ml/min and was monitored at 254 nm with a retention time of 3.049 minutes and 4.317 minutes for ceftriaxone and tazobactum respectively. The method was validated and the response was found to be linear in the drug concentration range of 20µg/ml to 80 µg/ml for ceftriaxone and 5 µg/ml to 35 µg/ml for tazobactum. The values of the correlation coefficient were found to be 0.999 for ceftriaxone and 0.999 for tazobactum respectively. The LOD and LOQ for ceftriaxone were found to be 0.021 and 0.064 respectively. The LOD and LOQ for tazobactum were found to be 0.030 and 0.091 respectively. The percentage recovery for ceftriaxone and tazobactum were found to be 98-102% respectively which indicates that the proposed method is highly accurate. The specificity of the method shows good correlation between retention times of standard with the sample. The method was extensively validated according to ICH guidelines for Linearity, Accuracy, Precision, Specificity and Robustness. Stability of the drugs was determined by using acid/base, thermal, oxidative stress testing.