{"title":"第三代Led LCU固化方式和固化次数对纳米复合材料力学性能的影响","authors":"B. Oglakci, Rümeysa Hatice Enginler Özlen, Metehan Demirkol, Z. C. Özduman, B. O. Kucukyildirim, E. Eliguzeloglu Dalkilic","doi":"10.15517/ijds.2022.49836","DOIUrl":null,"url":null,"abstract":"This study evaluates the effect of curing modes and times on the mechanical properties of nanocomposites. Two nanocomposite resins were investigated: supra-nanohybrid (Estelite Posterior Quick; EP) and nanohybrid (Solare X; SX). They were polymerized with a light-emitting diode light-curing units (LED LCU, Valo) as follows: standard mode for 20s (ST20), high power mode for 12s (HP12), high power mode for 20s (HP20), extra power mode for 6s (XP6), and extra power mode for 20s (XP20). For Vickers microhardness (HV), disc-shaped specimens were fabricated (n=10). For the three-point bending test, bar-shaped specimens were fabricated (n=10). Flexural strength and resilience modulus were calculated. The fractured surfaces and specimen surfaces of composites were observed using scanning electron microscopy. The data were analyzed with repeated measures ANOVA, two-way variance, and Bonferroni tests (p<0.05). On the top and bottom surfaces of the EP nanocomposite resin, ST20 and HP12 revealed statistically higher HV than with XP6. Moreover, HP20 and XP20 had statistically higher HV than HP12 and XP6. For the SX nanocomposite resin, HP20 had statistically higher HV than HP12. For EP and SX, there were no significant differences in flexural strength and resilience modulus regarding the curing modes and times. Furthermore, SX demonstrated lower mechanical properties than EP. Scanning electron microscopy indicated that both nanocomposites had similar surface appearances. However, with all curing modes and times, SX exhibited layered fractures and more crack formations than EP. Different curing modes and times could influence the microhardness of nanocomposites.","PeriodicalId":19450,"journal":{"name":"Odovtos - International Journal of Dental Sciences","volume":"58 1","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2022-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Effect of Curing Modes and Times of Third-Generation Led LCU on the Mechanical Properties of Nanocomposites\",\"authors\":\"B. Oglakci, Rümeysa Hatice Enginler Özlen, Metehan Demirkol, Z. C. Özduman, B. O. Kucukyildirim, E. Eliguzeloglu Dalkilic\",\"doi\":\"10.15517/ijds.2022.49836\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study evaluates the effect of curing modes and times on the mechanical properties of nanocomposites. Two nanocomposite resins were investigated: supra-nanohybrid (Estelite Posterior Quick; EP) and nanohybrid (Solare X; SX). They were polymerized with a light-emitting diode light-curing units (LED LCU, Valo) as follows: standard mode for 20s (ST20), high power mode for 12s (HP12), high power mode for 20s (HP20), extra power mode for 6s (XP6), and extra power mode for 20s (XP20). For Vickers microhardness (HV), disc-shaped specimens were fabricated (n=10). For the three-point bending test, bar-shaped specimens were fabricated (n=10). Flexural strength and resilience modulus were calculated. The fractured surfaces and specimen surfaces of composites were observed using scanning electron microscopy. The data were analyzed with repeated measures ANOVA, two-way variance, and Bonferroni tests (p<0.05). On the top and bottom surfaces of the EP nanocomposite resin, ST20 and HP12 revealed statistically higher HV than with XP6. Moreover, HP20 and XP20 had statistically higher HV than HP12 and XP6. For the SX nanocomposite resin, HP20 had statistically higher HV than HP12. For EP and SX, there were no significant differences in flexural strength and resilience modulus regarding the curing modes and times. Furthermore, SX demonstrated lower mechanical properties than EP. Scanning electron microscopy indicated that both nanocomposites had similar surface appearances. However, with all curing modes and times, SX exhibited layered fractures and more crack formations than EP. Different curing modes and times could influence the microhardness of nanocomposites.\",\"PeriodicalId\":19450,\"journal\":{\"name\":\"Odovtos - International Journal of Dental Sciences\",\"volume\":\"58 1\",\"pages\":\"\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2022-01-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Odovtos - International Journal of Dental Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15517/ijds.2022.49836\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Odovtos - International Journal of Dental Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15517/ijds.2022.49836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究了固化方式和固化时间对纳米复合材料力学性能的影响。研究了两种纳米复合树脂:超纳米复合树脂(Estelite Posterior Quick;EP)和纳米混合材料(Solare X;SX)。用发光二极管光固化单元(LED LCU, Valo)将其聚合为:20s的标准模式(ST20)、12s的高功率模式(HP12)、20s的高功率模式(HP20)、6s的额外功率模式(XP6)、20s的额外功率模式(XP20)。对于维氏显微硬度(HV),制作盘状试样(n=10)。三点弯曲试验采用杆形试件制作(n=10)。计算抗弯强度和回弹模量。用扫描电镜观察了复合材料的断裂面和试样表面。采用重复测量方差分析、双向方差分析和Bonferroni检验(p<0.05)对资料进行分析。在EP纳米复合树脂的上下表面,ST20和HP12的HV值均高于XP6。HP20、XP20的HV值高于HP12、XP6。对于SX纳米复合树脂,HP20的HV值明显高于HP12。EP和SX的抗弯强度和回弹模量不受养护方式和养护次数的影响。此外,SX的力学性能低于EP。扫描电镜显示两种纳米复合材料具有相似的表面形貌。然而,在所有的固化模式和时间下,SX都呈现出层状裂缝,裂缝形成比EP更多。不同的固化方式和固化时间会影响纳米复合材料的显微硬度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Effect of Curing Modes and Times of Third-Generation Led LCU on the Mechanical Properties of Nanocomposites
This study evaluates the effect of curing modes and times on the mechanical properties of nanocomposites. Two nanocomposite resins were investigated: supra-nanohybrid (Estelite Posterior Quick; EP) and nanohybrid (Solare X; SX). They were polymerized with a light-emitting diode light-curing units (LED LCU, Valo) as follows: standard mode for 20s (ST20), high power mode for 12s (HP12), high power mode for 20s (HP20), extra power mode for 6s (XP6), and extra power mode for 20s (XP20). For Vickers microhardness (HV), disc-shaped specimens were fabricated (n=10). For the three-point bending test, bar-shaped specimens were fabricated (n=10). Flexural strength and resilience modulus were calculated. The fractured surfaces and specimen surfaces of composites were observed using scanning electron microscopy. The data were analyzed with repeated measures ANOVA, two-way variance, and Bonferroni tests (p<0.05). On the top and bottom surfaces of the EP nanocomposite resin, ST20 and HP12 revealed statistically higher HV than with XP6. Moreover, HP20 and XP20 had statistically higher HV than HP12 and XP6. For the SX nanocomposite resin, HP20 had statistically higher HV than HP12. For EP and SX, there were no significant differences in flexural strength and resilience modulus regarding the curing modes and times. Furthermore, SX demonstrated lower mechanical properties than EP. Scanning electron microscopy indicated that both nanocomposites had similar surface appearances. However, with all curing modes and times, SX exhibited layered fractures and more crack formations than EP. Different curing modes and times could influence the microhardness of nanocomposites.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Odovtos - International Journal of Dental Sciences
Odovtos - International Journal of Dental Sciences DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.00
自引率
0.00%
发文量
50
审稿时长
8 weeks
期刊最新文献
Cephalometric Evaluation of the Relationship Between Cervical Vertebral Morphology and Anomalies and the Cranial Base Angle in Different Facial Types and Skeletal Classes Artificial Intelligence in Costa Rican Education Whitening Toothpastes Effect on Enamel Surface Morphology, Chemical Profile and Color: An In Vitro Study Salivary Cytokine Profile in Patients with Oral Lichen Planus Prevalence of Lesions and Oral Mucosal Normal Variations in an Elderly Population in Costa Rica
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1