{"title":"磁场定向控制感应电机驱动的改进容错变换器拓扑","authors":"B. S. S. G. Yelamarthi, Srinivasa Rao Sandepudi","doi":"10.1109/ICPECA47973.2019.8975694","DOIUrl":null,"url":null,"abstract":"A fault tolerant converter topology to mitigate open-circuit and short-circuit faults in the inverter fed induction motor drive using field oriented control (FOC) is proposed in this paper. The proposed converter consists of a current controlled 3-level boost converter to increase the dc-link voltage at the 2-level inverter during pre-fault and post-fault to meet rated load conditions of the induction motor and also to balance the capacitor voltages at the dc-link. Experimental results are presented for open-circuit and short-circuit fault of power devices in a 2-level inverter leg and also post-fault operation. The results of the 3-level boost converter fed induction motor drive combination shows the merits and also compared with fault-tolerant converter (B4) topology and conventional converter (B6) topology.","PeriodicalId":6761,"journal":{"name":"2019 International Conference on Power Electronics, Control and Automation (ICPECA)","volume":"5 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An Improved Fault Tolerant Converter Topology for Field Oriented Controlled Induction Motor Drive\",\"authors\":\"B. S. S. G. Yelamarthi, Srinivasa Rao Sandepudi\",\"doi\":\"10.1109/ICPECA47973.2019.8975694\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A fault tolerant converter topology to mitigate open-circuit and short-circuit faults in the inverter fed induction motor drive using field oriented control (FOC) is proposed in this paper. The proposed converter consists of a current controlled 3-level boost converter to increase the dc-link voltage at the 2-level inverter during pre-fault and post-fault to meet rated load conditions of the induction motor and also to balance the capacitor voltages at the dc-link. Experimental results are presented for open-circuit and short-circuit fault of power devices in a 2-level inverter leg and also post-fault operation. The results of the 3-level boost converter fed induction motor drive combination shows the merits and also compared with fault-tolerant converter (B4) topology and conventional converter (B6) topology.\",\"PeriodicalId\":6761,\"journal\":{\"name\":\"2019 International Conference on Power Electronics, Control and Automation (ICPECA)\",\"volume\":\"5 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Power Electronics, Control and Automation (ICPECA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPECA47973.2019.8975694\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Power Electronics, Control and Automation (ICPECA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPECA47973.2019.8975694","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An Improved Fault Tolerant Converter Topology for Field Oriented Controlled Induction Motor Drive
A fault tolerant converter topology to mitigate open-circuit and short-circuit faults in the inverter fed induction motor drive using field oriented control (FOC) is proposed in this paper. The proposed converter consists of a current controlled 3-level boost converter to increase the dc-link voltage at the 2-level inverter during pre-fault and post-fault to meet rated load conditions of the induction motor and also to balance the capacitor voltages at the dc-link. Experimental results are presented for open-circuit and short-circuit fault of power devices in a 2-level inverter leg and also post-fault operation. The results of the 3-level boost converter fed induction motor drive combination shows the merits and also compared with fault-tolerant converter (B4) topology and conventional converter (B6) topology.