电力系统动态系统分析

D. Clark
{"title":"电力系统动态系统分析","authors":"D. Clark","doi":"10.1109/TA.1965.4319790","DOIUrl":null,"url":null,"abstract":"This paper analyzes the rotating rectifier type aircraft generator system so that a digital computer study of system transient response may be made. A detailed analysis of the generator is made using Park's equations. This analysis results in a mathematical model which is quite easily handled by a digital computer. A single time constant transfer function is used for the exciter-rectifier which has proved sufficiently accurate. The generator analysis could be extended to the exciter and rectifier equations derived in Reference 3 used to obtain better accuracy if sufficient exciter-rectifier data is available. The regulator transfer function is a ratio of polynomials with limits and constants furnished by the designer. The purpose of this paper is to present the detailed generator analysis and briefly discuss the methods of representing other system elements and the computer program used for problem solution.","PeriodicalId":13050,"journal":{"name":"IEEE Transactions on Aerospace","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1965-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dynamic System Analysis for Electrical Power Systems\",\"authors\":\"D. Clark\",\"doi\":\"10.1109/TA.1965.4319790\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper analyzes the rotating rectifier type aircraft generator system so that a digital computer study of system transient response may be made. A detailed analysis of the generator is made using Park's equations. This analysis results in a mathematical model which is quite easily handled by a digital computer. A single time constant transfer function is used for the exciter-rectifier which has proved sufficiently accurate. The generator analysis could be extended to the exciter and rectifier equations derived in Reference 3 used to obtain better accuracy if sufficient exciter-rectifier data is available. The regulator transfer function is a ratio of polynomials with limits and constants furnished by the designer. The purpose of this paper is to present the detailed generator analysis and briefly discuss the methods of representing other system elements and the computer program used for problem solution.\",\"PeriodicalId\":13050,\"journal\":{\"name\":\"IEEE Transactions on Aerospace\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1965-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Aerospace\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TA.1965.4319790\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Aerospace","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TA.1965.4319790","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文对旋转整流型飞机发电机系统进行了分析,从而对系统的暂态响应进行了数字计算机研究。利用帕克方程对发电机进行了详细的分析。这种分析得到的数学模型很容易用数字计算机处理。励磁-整流器采用单一时间常数传递函数,证明了该传递函数的准确性。发电机分析可以推广到参考文献3中导出的励磁和整流方程,如果有足够的励磁-整流数据,可以获得更好的精度。调节器传递函数是由设计者提供的带有极限和常数的多项式之比。本文的目的是给出详细的生成器分析,并简要讨论其他系统元素的表示方法和用于解决问题的计算机程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dynamic System Analysis for Electrical Power Systems
This paper analyzes the rotating rectifier type aircraft generator system so that a digital computer study of system transient response may be made. A detailed analysis of the generator is made using Park's equations. This analysis results in a mathematical model which is quite easily handled by a digital computer. A single time constant transfer function is used for the exciter-rectifier which has proved sufficiently accurate. The generator analysis could be extended to the exciter and rectifier equations derived in Reference 3 used to obtain better accuracy if sufficient exciter-rectifier data is available. The regulator transfer function is a ratio of polynomials with limits and constants furnished by the designer. The purpose of this paper is to present the detailed generator analysis and briefly discuss the methods of representing other system elements and the computer program used for problem solution.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Modelling of Radiation Effects in Semiconductor Devices and Circuits Dynamic Response of an Asymmetrical Spinning Space Station A Digital System for the Acquisition and Analysis of Random Data Precisely Controlled 3-Phase Squirrel Cage Induction Motor Drives for Aerospace Applications Heat-Shield Ablation and Sublimation Determinations through Radioisotope Techniques
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1