球面正电子发射层析成像(S-PET) I -性能分析

Z.H. Cho , K.S. Hong, S.K. Hilal
{"title":"球面正电子发射层析成像(S-PET) I -性能分析","authors":"Z.H. Cho ,&nbsp;K.S. Hong,&nbsp;S.K. Hilal","doi":"10.1016/0167-5087(84)90282-5","DOIUrl":null,"url":null,"abstract":"<div><p>A spherical positron emission tomograph (S-PET) is proposed and its performance analyzed. Computer modelling and simulation studies indicate that a high resolution and high sensitivity positron emission tomograph having a spatial resolution of 2–3 mm fwhm can be realized with acceptable imaging time and sensitivity.</p><p>Multilayer S-PET having 16–24 layers is specifically analyzed and compared with its corresponding cylindrical counterpart. The result shows that the sensitivity gain of the spherical system is a factor 3 over the cylindrical system with identical true to scatter and random ratios.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 2","pages":"Pages 422-438"},"PeriodicalIF":0.0000,"publicationDate":"1984-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)90282-5","citationCount":"22","resultStr":"{\"title\":\"Spherical positron emission tomograph (S-PET) I - performance analysis\",\"authors\":\"Z.H. Cho ,&nbsp;K.S. Hong,&nbsp;S.K. Hilal\",\"doi\":\"10.1016/0167-5087(84)90282-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A spherical positron emission tomograph (S-PET) is proposed and its performance analyzed. Computer modelling and simulation studies indicate that a high resolution and high sensitivity positron emission tomograph having a spatial resolution of 2–3 mm fwhm can be realized with acceptable imaging time and sensitivity.</p><p>Multilayer S-PET having 16–24 layers is specifically analyzed and compared with its corresponding cylindrical counterpart. The result shows that the sensitivity gain of the spherical system is a factor 3 over the cylindrical system with identical true to scatter and random ratios.</p></div>\",\"PeriodicalId\":100972,\"journal\":{\"name\":\"Nuclear Instruments and Methods in Physics Research\",\"volume\":\"225 2\",\"pages\":\"Pages 422-438\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1984-08-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0167-5087(84)90282-5\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments and Methods in Physics Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0167508784902825\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments and Methods in Physics Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0167508784902825","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

摘要

提出了一种球形正电子发射层析成像仪(S-PET),并对其性能进行了分析。计算机模拟和仿真研究表明,在可接受的成像时间和灵敏度下,可以实现空间分辨率为2 ~ 3 mm / whm的高分辨率、高灵敏度正电子发射层析成像。对16-24层的多层S-PET进行了具体分析,并与相应的圆柱形S-PET进行了比较。结果表明,在真散射比和随机比相同的情况下,球形系统的灵敏度增益是圆柱形系统的3倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Spherical positron emission tomograph (S-PET) I - performance analysis

A spherical positron emission tomograph (S-PET) is proposed and its performance analyzed. Computer modelling and simulation studies indicate that a high resolution and high sensitivity positron emission tomograph having a spatial resolution of 2–3 mm fwhm can be realized with acceptable imaging time and sensitivity.

Multilayer S-PET having 16–24 layers is specifically analyzed and compared with its corresponding cylindrical counterpart. The result shows that the sensitivity gain of the spherical system is a factor 3 over the cylindrical system with identical true to scatter and random ratios.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Future needs and requirements for AMS 14C standards and reference materials. Nuclear Instruments and Methods in Physics Research Surface and bulk study of calcium phosphate bioceramics obtained by Metal Organic Chemical Vapor Deposition Subject index Author index Editorial
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1