一种用于神经信号处理的SC整流双积分电路:实验结果

Q4 Arts and Humanities Czas Kultury Pub Date : 2003-12-14 DOI:10.1109/ICECS.2003.1302027
A. Harb, M. Sawan
{"title":"一种用于神经信号处理的SC整流双积分电路:实验结果","authors":"A. Harb, M. Sawan","doi":"10.1109/ICECS.2003.1302027","DOIUrl":null,"url":null,"abstract":"In this paper, we describe a low-voltage CMOS switched-capacitor rectification and bin-integration (RBI) circuit dedicated to sensor electronic interfaces. The applications of these interfaces are among others, biomedical and more particularly the implantable devices. RBI is the most common signal processing function applied to the nerve signals. Since the frequency of these signals is below 10 kHz, a switched-capacitor architecture has been used. The circuit comprises an always-valid sample and hold circuit followed by a full wave rectifier. The bin-integration is then performed with three resettable integration stages. The third stage is reset in such a way to use the maximum range of the ADC. The resulting RBI signal is then converted to digital and transferred to the implant central processor where information about bladder could be extracted. The circuit has been realized in CMOS 0.35 /spl mu/m, 3.3 V technology. The design, simulation and measurement results of the proposed interface are presented. At 1.3 V supply, the measured circuit obtains an RBI error of less than -45 dB for a sinewave input of 7.2 kHz that is the main component of the nerve signal and a dynamic range of /spl plusmn/1.1 V while dissipating 578 /spl mu/W and occupying a chip area of 5.83 mm/sup 2/.","PeriodicalId":36912,"journal":{"name":"Czas Kultury","volume":"2 1","pages":"264-267 Vol.1"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A SC rectification and bin-integration circuit for nerve signal processing: experimental results\",\"authors\":\"A. Harb, M. Sawan\",\"doi\":\"10.1109/ICECS.2003.1302027\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, we describe a low-voltage CMOS switched-capacitor rectification and bin-integration (RBI) circuit dedicated to sensor electronic interfaces. The applications of these interfaces are among others, biomedical and more particularly the implantable devices. RBI is the most common signal processing function applied to the nerve signals. Since the frequency of these signals is below 10 kHz, a switched-capacitor architecture has been used. The circuit comprises an always-valid sample and hold circuit followed by a full wave rectifier. The bin-integration is then performed with three resettable integration stages. The third stage is reset in such a way to use the maximum range of the ADC. The resulting RBI signal is then converted to digital and transferred to the implant central processor where information about bladder could be extracted. The circuit has been realized in CMOS 0.35 /spl mu/m, 3.3 V technology. The design, simulation and measurement results of the proposed interface are presented. At 1.3 V supply, the measured circuit obtains an RBI error of less than -45 dB for a sinewave input of 7.2 kHz that is the main component of the nerve signal and a dynamic range of /spl plusmn/1.1 V while dissipating 578 /spl mu/W and occupying a chip area of 5.83 mm/sup 2/.\",\"PeriodicalId\":36912,\"journal\":{\"name\":\"Czas Kultury\",\"volume\":\"2 1\",\"pages\":\"264-267 Vol.1\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-12-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Czas Kultury\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICECS.2003.1302027\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Arts and Humanities\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Czas Kultury","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECS.2003.1302027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Arts and Humanities","Score":null,"Total":0}
引用次数: 5

摘要

本文描述了一种专用于传感器电子接口的低压CMOS开关电容整流与集成电路(RBI)。这些接口的应用包括生物医学,尤其是植入式设备。RBI是应用于神经信号的最常用的信号处理函数。由于这些信号的频率低于10khz,因此使用了开关电容器结构。该电路包括一个始终有效的采样和保持电路,然后是一个全波整流器。然后通过三个可重置的集成阶段执行bin集成。第三阶段以这样的方式复位,以使用ADC的最大量程。得到的RBI信号被转换成数字信号并传输到植入体的中央处理器,在那里可以提取膀胱的信息。电路在CMOS 0.35 /spl mu/m, 3.3 V技术下实现。给出了该接口的设计、仿真和测试结果。在1.3 V电源下,当神经信号的主要成分为7.2 kHz的正弦波输入,动态范围为/spl plusmn/1.1 V时,被测电路的RBI误差小于-45 dB,而功耗为578 /spl mu/W,芯片面积为5.83 mm/sup 2/。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A SC rectification and bin-integration circuit for nerve signal processing: experimental results
In this paper, we describe a low-voltage CMOS switched-capacitor rectification and bin-integration (RBI) circuit dedicated to sensor electronic interfaces. The applications of these interfaces are among others, biomedical and more particularly the implantable devices. RBI is the most common signal processing function applied to the nerve signals. Since the frequency of these signals is below 10 kHz, a switched-capacitor architecture has been used. The circuit comprises an always-valid sample and hold circuit followed by a full wave rectifier. The bin-integration is then performed with three resettable integration stages. The third stage is reset in such a way to use the maximum range of the ADC. The resulting RBI signal is then converted to digital and transferred to the implant central processor where information about bladder could be extracted. The circuit has been realized in CMOS 0.35 /spl mu/m, 3.3 V technology. The design, simulation and measurement results of the proposed interface are presented. At 1.3 V supply, the measured circuit obtains an RBI error of less than -45 dB for a sinewave input of 7.2 kHz that is the main component of the nerve signal and a dynamic range of /spl plusmn/1.1 V while dissipating 578 /spl mu/W and occupying a chip area of 5.83 mm/sup 2/.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Czas Kultury
Czas Kultury Social Sciences-Social Sciences (miscellaneous)
CiteScore
0.10
自引率
0.00%
发文量
10
期刊最新文献
Aktywizm dający przyjemność: działanie na zasadzie wspólnej zgody, lokalne zakorzenienie i oddolne polityki integracyjne Ekopareneza. Rozpoznania wstępne Paradoks Kasztanki. Fantazmatyczne eksponaty w domach-muzeach Luzowanie ontologii. O wytwarzaniu więcej-niż-ludzkich lokalności na Górnym Śląsku Przez negantropologię do obywatelskiej rewolucji w lokalnościach
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1