Y. Srinivas, M. Kushwah, S. Kulkarni, K. Sathyanarayana, P. Khilar, B. Pal, P. Shah, A. Makwana, B. Kadia, K. Parmar, S. Dani, R. Singh, K. Parmar, D. Bora
{"title":"70kv高功率速调管和回旋管轨隙保护系统10焦耳烧线试验结果","authors":"Y. Srinivas, M. Kushwah, S. Kulkarni, K. Sathyanarayana, P. Khilar, B. Pal, P. Shah, A. Makwana, B. Kadia, K. Parmar, S. Dani, R. Singh, K. Parmar, D. Bora","doi":"10.1109/FUSION.2002.1027650","DOIUrl":null,"url":null,"abstract":"Pulsed and continuous high power microwave tubes need to be protected against arc faults within the tube. If the energy dumped in such arc fault is more than the critical crater energy of the tube, irreparable damage can occur. Modern switch mode powers supplies (SMPS) that are generally opted for the new systems store little energy and are capable of switching HV in few microseconds. So they do not need separate protection. However, when conventional power supplies feed high power microwave tubes a reliable crowbar protection system, tested separately to limit the energy, must be used to assure the tube safety. Initial testing and commissioning of two klystrons, TH2103D have been carried out at our Institute. Each of these klystrons is capable of delivering 500 kW at 3.7 GHz, to be used for non-inductive lower hybrid current drive (LHCD) In the Steady-State Superconducting Tokamak-1 (SST-1). Commissioning of the gyrotron VGA8000A19, for breakdown and electron cyclotron resonant heating (ECRH) experiments on Aditya tokamak, has also been carried out.","PeriodicalId":44192,"journal":{"name":"NINETEENTH CENTURY MUSIC","volume":"2 1","pages":"91-94"},"PeriodicalIF":0.3000,"publicationDate":"2002-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Results of 10-Joule wire-burn test performed on 70 kV rail-gap crowbar protection system for high power klystrons and gyrotron\",\"authors\":\"Y. Srinivas, M. Kushwah, S. Kulkarni, K. Sathyanarayana, P. Khilar, B. Pal, P. Shah, A. Makwana, B. Kadia, K. Parmar, S. Dani, R. Singh, K. Parmar, D. Bora\",\"doi\":\"10.1109/FUSION.2002.1027650\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Pulsed and continuous high power microwave tubes need to be protected against arc faults within the tube. If the energy dumped in such arc fault is more than the critical crater energy of the tube, irreparable damage can occur. Modern switch mode powers supplies (SMPS) that are generally opted for the new systems store little energy and are capable of switching HV in few microseconds. So they do not need separate protection. However, when conventional power supplies feed high power microwave tubes a reliable crowbar protection system, tested separately to limit the energy, must be used to assure the tube safety. Initial testing and commissioning of two klystrons, TH2103D have been carried out at our Institute. Each of these klystrons is capable of delivering 500 kW at 3.7 GHz, to be used for non-inductive lower hybrid current drive (LHCD) In the Steady-State Superconducting Tokamak-1 (SST-1). Commissioning of the gyrotron VGA8000A19, for breakdown and electron cyclotron resonant heating (ECRH) experiments on Aditya tokamak, has also been carried out.\",\"PeriodicalId\":44192,\"journal\":{\"name\":\"NINETEENTH CENTURY MUSIC\",\"volume\":\"2 1\",\"pages\":\"91-94\"},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2002-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"NINETEENTH CENTURY MUSIC\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FUSION.2002.1027650\",\"RegionNum\":1,\"RegionCategory\":\"艺术学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"0\",\"JCRName\":\"MUSIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"NINETEENTH CENTURY MUSIC","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FUSION.2002.1027650","RegionNum":1,"RegionCategory":"艺术学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"MUSIC","Score":null,"Total":0}
Results of 10-Joule wire-burn test performed on 70 kV rail-gap crowbar protection system for high power klystrons and gyrotron
Pulsed and continuous high power microwave tubes need to be protected against arc faults within the tube. If the energy dumped in such arc fault is more than the critical crater energy of the tube, irreparable damage can occur. Modern switch mode powers supplies (SMPS) that are generally opted for the new systems store little energy and are capable of switching HV in few microseconds. So they do not need separate protection. However, when conventional power supplies feed high power microwave tubes a reliable crowbar protection system, tested separately to limit the energy, must be used to assure the tube safety. Initial testing and commissioning of two klystrons, TH2103D have been carried out at our Institute. Each of these klystrons is capable of delivering 500 kW at 3.7 GHz, to be used for non-inductive lower hybrid current drive (LHCD) In the Steady-State Superconducting Tokamak-1 (SST-1). Commissioning of the gyrotron VGA8000A19, for breakdown and electron cyclotron resonant heating (ECRH) experiments on Aditya tokamak, has also been carried out.
期刊介绍:
19th-Century Music covers all aspects of Western art music between the mid-eighteenth and mid-twentieth centuries. We welcome--in no particular order--considerations of composers and compositions, styles, performance, historical watersheds, cultural formations, critical methods, musical institutions, ideas, and topics not named on this list. Our aim is to publish contributions to ongoing conversations at the leading edge of musical and multidisciplinary scholarship.