基于鲁棒自适应双边滤波器的低计数SPECT投影数据去噪

S. Nakabayashi, Takashi Chikamatsu, Takao Okamoto, T. Kaminaga, N. Arai, S. Kumagai, K. Shiraishi, T. Okamoto, Takenori Kobayashi, J. Kotoku
{"title":"基于鲁棒自适应双边滤波器的低计数SPECT投影数据去噪","authors":"S. Nakabayashi, Takashi Chikamatsu, Takao Okamoto, T. Kaminaga, N. Arai, S. Kumagai, K. Shiraishi, T. Okamoto, Takenori Kobayashi, J. Kotoku","doi":"10.4236/ijmpcero.2018.73030","DOIUrl":null,"url":null,"abstract":"Low-count SPECT images are \nwell known to be smoothed strongly by a Butterworth filter for statistical \nnoise reduction. Reconstructed images have a low signal-to-noise ratio (SNR) \nand spatial resolution because of the removal of high-frequency signal \ncomponents. Using the developed robust adaptive bilateral filter (RABF), which \nwas designed as a pre-stage filter of the Butterworth filter, this study was \nconducted to improve SNR without degrading the spatial resolution for low-count \nSPECT imaging. The filter can remove noise while preserving spatial resolution. \nTo evaluate the proposed method, we extracted SNR and spatial resolution in a \nphantom study. We also conducted paired comparison for \nvisual image quality evaluation in a clinical study. Results show that SNR \nwas increased 1.4 times without degrading the spatial resolution. Visual image \nquality was improved significantly (p < 0.01) for clinical low-count data. \nMoreover, the accumulation structure became sharper. A structure embedded in \nnoise emerged. Our method, which denoises without degrading the spatial \nresolution for low-count SPECT images, is expected to increase the \neffectiveness of diagnosis for low-dose scanning and short acquisition time \nscanning.","PeriodicalId":14028,"journal":{"name":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Denoising Projection Data with a Robust Adaptive Bilateral Filter in Low-Count SPECT\",\"authors\":\"S. Nakabayashi, Takashi Chikamatsu, Takao Okamoto, T. Kaminaga, N. Arai, S. Kumagai, K. Shiraishi, T. Okamoto, Takenori Kobayashi, J. Kotoku\",\"doi\":\"10.4236/ijmpcero.2018.73030\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Low-count SPECT images are \\nwell known to be smoothed strongly by a Butterworth filter for statistical \\nnoise reduction. Reconstructed images have a low signal-to-noise ratio (SNR) \\nand spatial resolution because of the removal of high-frequency signal \\ncomponents. Using the developed robust adaptive bilateral filter (RABF), which \\nwas designed as a pre-stage filter of the Butterworth filter, this study was \\nconducted to improve SNR without degrading the spatial resolution for low-count \\nSPECT imaging. The filter can remove noise while preserving spatial resolution. \\nTo evaluate the proposed method, we extracted SNR and spatial resolution in a \\nphantom study. We also conducted paired comparison for \\nvisual image quality evaluation in a clinical study. Results show that SNR \\nwas increased 1.4 times without degrading the spatial resolution. Visual image \\nquality was improved significantly (p < 0.01) for clinical low-count data. \\nMoreover, the accumulation structure became sharper. A structure embedded in \\nnoise emerged. Our method, which denoises without degrading the spatial \\nresolution for low-count SPECT images, is expected to increase the \\neffectiveness of diagnosis for low-dose scanning and short acquisition time \\nscanning.\",\"PeriodicalId\":14028,\"journal\":{\"name\":\"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4236/ijmpcero.2018.73030\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/ijmpcero.2018.73030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

众所周知,低计数SPECT图像被巴特沃斯滤波器平滑,用于统计降噪。由于去除了高频信号成分,重构图像具有较低的信噪比和空间分辨率。利用开发的鲁棒自适应双边滤波器(RABF)作为Butterworth滤波器的前级滤波器,在不降低低计数SPECT成像空间分辨率的情况下提高了信噪比。该滤波器可以在保持空间分辨率的同时去除噪声。为了评估所提出的方法,我们在模拟研究中提取了信噪比和空间分辨率。我们还在临床研究中进行了视觉图像质量评价的配对比较。结果表明,在不降低空间分辨率的情况下,信噪比提高了1.4倍。临床低计数数据的视觉图像质量显著提高(p < 0.01)。堆积结构更加尖锐。一个嵌在噪音中的结构出现了。我们的方法在不降低低计数SPECT图像空间分辨率的情况下去噪,有望提高低剂量扫描和短采集时间扫描的诊断效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Denoising Projection Data with a Robust Adaptive Bilateral Filter in Low-Count SPECT
Low-count SPECT images are well known to be smoothed strongly by a Butterworth filter for statistical noise reduction. Reconstructed images have a low signal-to-noise ratio (SNR) and spatial resolution because of the removal of high-frequency signal components. Using the developed robust adaptive bilateral filter (RABF), which was designed as a pre-stage filter of the Butterworth filter, this study was conducted to improve SNR without degrading the spatial resolution for low-count SPECT imaging. The filter can remove noise while preserving spatial resolution. To evaluate the proposed method, we extracted SNR and spatial resolution in a phantom study. We also conducted paired comparison for visual image quality evaluation in a clinical study. Results show that SNR was increased 1.4 times without degrading the spatial resolution. Visual image quality was improved significantly (p < 0.01) for clinical low-count data. Moreover, the accumulation structure became sharper. A structure embedded in noise emerged. Our method, which denoises without degrading the spatial resolution for low-count SPECT images, is expected to increase the effectiveness of diagnosis for low-dose scanning and short acquisition time scanning.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Assessment of Monitor Units and Gamma Pass Rate for 6 MV and Flattening Filter Free (FFF) Beams in Volumetric Modulated Arc Therapy (VMAT) The Journey of SRS: An Initial Experience of Starting Sterotactic Radiosurgery Facility at Purbanchal Cancer Hospital—First in Nepal Hereditary Multiple Exostoses (HME) with Peroneal Nerve Compresion: A Case Report Dosimetric Study of the Effect of Calypso-Compatible Couch Top for Spine Stereotactic Body Radiation Therapy Radiation-Associated Cardiotoxicity during Breast Cancer Treatment with Ionizing Radiation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1