{"title":"一种测量医护人员手卫生表现的整体水平手卫生监测技术的评估","authors":"H. Limper, L. Slawsky, Sylvia Garcia-Houchins, S. Mehta, R. Hershow, E. Landon","doi":"10.1017/ice.2016.298","DOIUrl":null,"url":null,"abstract":"BACKGROUND Despite significant advances in technological methods for hand hygiene surveillance, a lack of evidence prohibits comparison of systems to one another or against the current gold standard of direct observation. OBJECTIVE To validate a hand hygiene monitoring technology (HHMT) designed to capture hand hygiene behaviors aggregated at the hospital-unit level (GOJO Industries, Akron, OH). METHODS Our team followed a rigorous validation approach to assess the sensitivity and positive predictive value (PPV) of an HHMT. A planned path was first used to measure the accuracy of the system when purposefully activated by investigators. Next, behavioral validation was used to quantify accuracy of the system in capturing real-world behaviors. RESULTS During the planned path phase, investigators performed 4,872 unique events across 3 distinct hospital buildings varying in size and age since construction. Overall sensitivity across the medical center was 88.7% with a PPV of 99.2%. During the behavioral validation phase, trained direct observers recorded 5,539 unique events across 3 distinct hospital buildings. Overall sensitivity across the medical center was 92.7% and PPV was 84.4%. CONCLUSION Objective measures of sensitivity and PPV indicate the promise of the benefit of this and other HHMTs to capture basic behaviors associated with hand hygiene. Infect Control Hosp Epidemiol 2017;38:348–352","PeriodicalId":13655,"journal":{"name":"Infection Control & Hospital Epidemiology","volume":"23 1","pages":"348 - 352"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":"{\"title\":\"Assessment of an Aggregate-Level Hand Hygiene Monitoring Technology for Measuring Hand Hygiene Performance Among Healthcare Personnel\",\"authors\":\"H. Limper, L. Slawsky, Sylvia Garcia-Houchins, S. Mehta, R. Hershow, E. Landon\",\"doi\":\"10.1017/ice.2016.298\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BACKGROUND Despite significant advances in technological methods for hand hygiene surveillance, a lack of evidence prohibits comparison of systems to one another or against the current gold standard of direct observation. OBJECTIVE To validate a hand hygiene monitoring technology (HHMT) designed to capture hand hygiene behaviors aggregated at the hospital-unit level (GOJO Industries, Akron, OH). METHODS Our team followed a rigorous validation approach to assess the sensitivity and positive predictive value (PPV) of an HHMT. A planned path was first used to measure the accuracy of the system when purposefully activated by investigators. Next, behavioral validation was used to quantify accuracy of the system in capturing real-world behaviors. RESULTS During the planned path phase, investigators performed 4,872 unique events across 3 distinct hospital buildings varying in size and age since construction. Overall sensitivity across the medical center was 88.7% with a PPV of 99.2%. During the behavioral validation phase, trained direct observers recorded 5,539 unique events across 3 distinct hospital buildings. Overall sensitivity across the medical center was 92.7% and PPV was 84.4%. CONCLUSION Objective measures of sensitivity and PPV indicate the promise of the benefit of this and other HHMTs to capture basic behaviors associated with hand hygiene. Infect Control Hosp Epidemiol 2017;38:348–352\",\"PeriodicalId\":13655,\"journal\":{\"name\":\"Infection Control & Hospital Epidemiology\",\"volume\":\"23 1\",\"pages\":\"348 - 352\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Infection Control & Hospital Epidemiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1017/ice.2016.298\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infection Control & Hospital Epidemiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/ice.2016.298","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Assessment of an Aggregate-Level Hand Hygiene Monitoring Technology for Measuring Hand Hygiene Performance Among Healthcare Personnel
BACKGROUND Despite significant advances in technological methods for hand hygiene surveillance, a lack of evidence prohibits comparison of systems to one another or against the current gold standard of direct observation. OBJECTIVE To validate a hand hygiene monitoring technology (HHMT) designed to capture hand hygiene behaviors aggregated at the hospital-unit level (GOJO Industries, Akron, OH). METHODS Our team followed a rigorous validation approach to assess the sensitivity and positive predictive value (PPV) of an HHMT. A planned path was first used to measure the accuracy of the system when purposefully activated by investigators. Next, behavioral validation was used to quantify accuracy of the system in capturing real-world behaviors. RESULTS During the planned path phase, investigators performed 4,872 unique events across 3 distinct hospital buildings varying in size and age since construction. Overall sensitivity across the medical center was 88.7% with a PPV of 99.2%. During the behavioral validation phase, trained direct observers recorded 5,539 unique events across 3 distinct hospital buildings. Overall sensitivity across the medical center was 92.7% and PPV was 84.4%. CONCLUSION Objective measures of sensitivity and PPV indicate the promise of the benefit of this and other HHMTs to capture basic behaviors associated with hand hygiene. Infect Control Hosp Epidemiol 2017;38:348–352