基于微生物处理工艺的火电厂循环冷却水处理

IF 1 4区 工程技术 Q4 ENGINEERING, CHEMICAL Desalination and Water Treatment Pub Date : 2023-01-01 DOI:10.5004/dwt.2023.29362
Ning Liu, Xing-yu Liu, Liangshi Wang, Xuezhe Zhu, Q. Gu
{"title":"基于微生物处理工艺的火电厂循环冷却水处理","authors":"Ning Liu, Xing-yu Liu, Liangshi Wang, Xuezhe Zhu, Q. Gu","doi":"10.5004/dwt.2023.29362","DOIUrl":null,"url":null,"abstract":"Circulating cooling water consumes a large amount of water in thermal power plant, and there are some problems such as scaling and corrosion in the system. This study presents a novel circulating cooling water treatment process based on microbes. The mechanism and influencing factors of microbial treatment process of circulating cooling water is studied. Water from circulating cooling system of a 300 MW thermal power unit was used, dynamic simulation test was carried out and com- pared between the microbial treatment process and the traditional chemical treatment process. The results showed that nutrient solution dosage on calcium hardness is positive, while the interaction between nutrient solution dosage and aeration rate has negative effect. When ammonia concentration is 10–50 mg/L and aeration rate is 1–3 L, and the minimum calcium hardness is 18.3 mmol/L. Reducing the concentration of nutrient solution and increasing the aeration rate are beneficial to slow down the corrosion of carbon steel and stainless steel. When ammonia concentration is 10–50 mg/L and aeration rate is 1–3 L, the minimum corrosion rates are 0.01552 and 0.00110 mm/a, respectively. Compared with traditional chemical treatment process, the microbial treatment process can achieve the scale inhibition and corrosion inhibition target at high concentration ratio, the highest concentration ratio can reach 5.4, and the corrosion rate of carbon steel and stainless steel is low. The green, efficient and environment-friendly microbial treatment process provides a new method for circulating cooling water treatment, which can obtain stable and economical operation of circulating cooling water system under high concentration ratio.","PeriodicalId":11260,"journal":{"name":"Desalination and Water Treatment","volume":"33 1","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Circulating cooling water treatment of thermal power plant based on microbial treatment process\",\"authors\":\"Ning Liu, Xing-yu Liu, Liangshi Wang, Xuezhe Zhu, Q. Gu\",\"doi\":\"10.5004/dwt.2023.29362\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Circulating cooling water consumes a large amount of water in thermal power plant, and there are some problems such as scaling and corrosion in the system. This study presents a novel circulating cooling water treatment process based on microbes. The mechanism and influencing factors of microbial treatment process of circulating cooling water is studied. Water from circulating cooling system of a 300 MW thermal power unit was used, dynamic simulation test was carried out and com- pared between the microbial treatment process and the traditional chemical treatment process. The results showed that nutrient solution dosage on calcium hardness is positive, while the interaction between nutrient solution dosage and aeration rate has negative effect. When ammonia concentration is 10–50 mg/L and aeration rate is 1–3 L, and the minimum calcium hardness is 18.3 mmol/L. Reducing the concentration of nutrient solution and increasing the aeration rate are beneficial to slow down the corrosion of carbon steel and stainless steel. When ammonia concentration is 10–50 mg/L and aeration rate is 1–3 L, the minimum corrosion rates are 0.01552 and 0.00110 mm/a, respectively. Compared with traditional chemical treatment process, the microbial treatment process can achieve the scale inhibition and corrosion inhibition target at high concentration ratio, the highest concentration ratio can reach 5.4, and the corrosion rate of carbon steel and stainless steel is low. The green, efficient and environment-friendly microbial treatment process provides a new method for circulating cooling water treatment, which can obtain stable and economical operation of circulating cooling water system under high concentration ratio.\",\"PeriodicalId\":11260,\"journal\":{\"name\":\"Desalination and Water Treatment\",\"volume\":\"33 1\",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Desalination and Water Treatment\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.5004/dwt.2023.29362\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, CHEMICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Desalination and Water Treatment","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.5004/dwt.2023.29362","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

摘要

火电厂循环冷却水耗水量大,系统存在结垢、腐蚀等问题。提出了一种基于微生物的循环冷却水处理新工艺。研究了循环冷却水微生物处理过程的机理及影响因素。以某300mw火电机组循环冷却水为对象,进行了动态模拟试验,并对微生物处理工艺与传统化学处理工艺进行了比较。结果表明,营养液用量对钙硬度的影响为正,而营养液用量与曝气速率的交互作用为负。当氨浓度为10 ~ 50 mg/L,曝气量为1 ~ 3 L时,钙的最小硬度为18.3 mmol/L。降低营养液浓度,提高曝气速率,有利于减缓碳钢和不锈钢的腐蚀。当氨浓度为10 ~ 50 mg/L,曝气量为1 ~ 3 L时,腐蚀速率最小分别为0.01552 mm/a和0.00110 mm/a。与传统化学处理工艺相比,微生物处理工艺可在高浓度比下达到阻垢缓蚀目标,最高浓度比可达5.4,对碳钢和不锈钢的腐蚀速率较低。绿色、高效、环保的微生物处理工艺为循环冷却水处理提供了一种新的方法,可获得高浓度比下循环冷却水系统的稳定、经济运行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Circulating cooling water treatment of thermal power plant based on microbial treatment process
Circulating cooling water consumes a large amount of water in thermal power plant, and there are some problems such as scaling and corrosion in the system. This study presents a novel circulating cooling water treatment process based on microbes. The mechanism and influencing factors of microbial treatment process of circulating cooling water is studied. Water from circulating cooling system of a 300 MW thermal power unit was used, dynamic simulation test was carried out and com- pared between the microbial treatment process and the traditional chemical treatment process. The results showed that nutrient solution dosage on calcium hardness is positive, while the interaction between nutrient solution dosage and aeration rate has negative effect. When ammonia concentration is 10–50 mg/L and aeration rate is 1–3 L, and the minimum calcium hardness is 18.3 mmol/L. Reducing the concentration of nutrient solution and increasing the aeration rate are beneficial to slow down the corrosion of carbon steel and stainless steel. When ammonia concentration is 10–50 mg/L and aeration rate is 1–3 L, the minimum corrosion rates are 0.01552 and 0.00110 mm/a, respectively. Compared with traditional chemical treatment process, the microbial treatment process can achieve the scale inhibition and corrosion inhibition target at high concentration ratio, the highest concentration ratio can reach 5.4, and the corrosion rate of carbon steel and stainless steel is low. The green, efficient and environment-friendly microbial treatment process provides a new method for circulating cooling water treatment, which can obtain stable and economical operation of circulating cooling water system under high concentration ratio.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Desalination and Water Treatment
Desalination and Water Treatment 工程技术-工程:化工
CiteScore
2.20
自引率
9.10%
发文量
0
审稿时长
5.3 months
期刊介绍: The journal is dedicated to research and application of desalination technology, environment and energy considerations, integrated water management, water reuse, wastewater and related topics.
期刊最新文献
The use of modified multi-walled carbon nanotubes for the removal of selected pharmaceuticals from the aqueous environment Removal of Cr(III) from tannery wastewater using Citrus aurantium (grapefruit peel) as biosorbent Impact of chitosan on CS/TiO2 composite system for enhancing its photocatalytic performance towards dye degradation Enabled geographic information system technology toward non-revenue water reduction Statement of retraction "Evaluating the reuse and recycling options of end-of-life reverse osmosis membranes in Tajoura desalination plant" published in vol. 263 (2022) pp. 45-52 [doi:10.5004/dwt.2022.28205]
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1