种植保留下颌覆盖义齿:7年后患者功能相关的结果测量

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Open Dentistry Journal Pub Date : 2022-05-01 DOI:10.3390/dj10050088
Jan D'haese, C. Matthys, H. Sahak, Jos Besseler, H. De Bruyn
{"title":"种植保留下颌覆盖义齿:7年后患者功能相关的结果测量","authors":"Jan D'haese, C. Matthys, H. Sahak, Jos Besseler, H. De Bruyn","doi":"10.3390/dj10050088","DOIUrl":null,"url":null,"abstract":"Denture wearers often complain about jeopardized function and reduced quality of life due to lack of prosthesis’ retention. Implant-retained mandibular overdentures, on two non-connected implants (2IOD) are well-proven solutions to overcome these issues. We prospectively assessed 69 patients and scrutinized clinical records until at least seven years of function. Thirty-six were retained on Locator® Abutments (LA) and thirty-tree on Ball Abutments (BA). Both systems were compared regarding the type, amount, and total cost of required maintenance. One implant was lost, yielding 98.7% survival after seven years. In total, 438 technical issues occurred: 121 (27.35%) in BA and 317 (72.4%) in LA. Out of these, 343 events (78%) were solved chairside: 191 (43.6%) were replacements of retention caps, 113 (25.8%) were minor acrylic repairs, 26 (5.9%) pressure ulcers had to be relieved, and 13 (3%) were related to abutments. LA required 179 insert replacements compared to 12 in the BA group. The overall initial treatment cost was EUR 3850 (base year of the analysis: 2003). The average total maintenance cost in relation to the initial cost for the LA and BA groups was 19.11 (range 0–82.24%) and 18.91% (range 0–113.26%) respectively (p = 0.540). Conclusions: The seven-year maintenance costs for a 2IOD is acceptable when the patient is regularly checked and professionally maintained. Most events are easily solvable chairside, but a few patients required more expensive interventions, regardless of the type of attachment used.","PeriodicalId":47284,"journal":{"name":"Open Dentistry Journal","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Implant-Retained Mandibular Overdentures: Patient-Related Outcome Measurements after Seven Years of Function\",\"authors\":\"Jan D'haese, C. Matthys, H. Sahak, Jos Besseler, H. De Bruyn\",\"doi\":\"10.3390/dj10050088\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Denture wearers often complain about jeopardized function and reduced quality of life due to lack of prosthesis’ retention. Implant-retained mandibular overdentures, on two non-connected implants (2IOD) are well-proven solutions to overcome these issues. We prospectively assessed 69 patients and scrutinized clinical records until at least seven years of function. Thirty-six were retained on Locator® Abutments (LA) and thirty-tree on Ball Abutments (BA). Both systems were compared regarding the type, amount, and total cost of required maintenance. One implant was lost, yielding 98.7% survival after seven years. In total, 438 technical issues occurred: 121 (27.35%) in BA and 317 (72.4%) in LA. Out of these, 343 events (78%) were solved chairside: 191 (43.6%) were replacements of retention caps, 113 (25.8%) were minor acrylic repairs, 26 (5.9%) pressure ulcers had to be relieved, and 13 (3%) were related to abutments. LA required 179 insert replacements compared to 12 in the BA group. The overall initial treatment cost was EUR 3850 (base year of the analysis: 2003). The average total maintenance cost in relation to the initial cost for the LA and BA groups was 19.11 (range 0–82.24%) and 18.91% (range 0–113.26%) respectively (p = 0.540). Conclusions: The seven-year maintenance costs for a 2IOD is acceptable when the patient is regularly checked and professionally maintained. Most events are easily solvable chairside, but a few patients required more expensive interventions, regardless of the type of attachment used.\",\"PeriodicalId\":47284,\"journal\":{\"name\":\"Open Dentistry Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2022-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open Dentistry Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/dj10050088\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj10050088","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

摘要

假牙佩戴者经常抱怨由于缺乏义齿固位而损害功能和降低生活质量。种植体保留下颌覆盖假牙,在两个非连接种植体上(2IOD)是克服这些问题的行之有效的解决方案。我们前瞻性地评估了69例患者,并仔细检查了临床记录,直到至少7年的功能。36只保留在Locator®基台(LA)上,30只保留在Ball基台(BA)上。对两种系统的类型、数量和所需维护的总成本进行了比较。一颗植入物丢失,7年后存活率为98.7%。总共发生了438个技术问题:BA有121个(27.35%),LA有317个(72.4%)。其中,343例(78%)在椅子旁得到解决:191例(43.6%)更换固定帽,113例(25.8%)进行小型丙烯酸修复,26例(5.9%)必须缓解压疮,13例(3%)与基台有关。LA组需要179个插入物更换,而BA组只需要12个。总体初始治疗费用为3850欧元(分析基准年:2003年)。LA组和BA组的平均总维护成本相对于初始成本分别为19.11%(范围0-82.24%)和18.91%(范围0-113.26%)(p = 0.540)。结论:在定期检查和专业维护的情况下,2IOD的7年维护费用是可以接受的。大多数事件都很容易解决,但少数患者需要更昂贵的干预措施,无论使用哪种附件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Implant-Retained Mandibular Overdentures: Patient-Related Outcome Measurements after Seven Years of Function
Denture wearers often complain about jeopardized function and reduced quality of life due to lack of prosthesis’ retention. Implant-retained mandibular overdentures, on two non-connected implants (2IOD) are well-proven solutions to overcome these issues. We prospectively assessed 69 patients and scrutinized clinical records until at least seven years of function. Thirty-six were retained on Locator® Abutments (LA) and thirty-tree on Ball Abutments (BA). Both systems were compared regarding the type, amount, and total cost of required maintenance. One implant was lost, yielding 98.7% survival after seven years. In total, 438 technical issues occurred: 121 (27.35%) in BA and 317 (72.4%) in LA. Out of these, 343 events (78%) were solved chairside: 191 (43.6%) were replacements of retention caps, 113 (25.8%) were minor acrylic repairs, 26 (5.9%) pressure ulcers had to be relieved, and 13 (3%) were related to abutments. LA required 179 insert replacements compared to 12 in the BA group. The overall initial treatment cost was EUR 3850 (base year of the analysis: 2003). The average total maintenance cost in relation to the initial cost for the LA and BA groups was 19.11 (range 0–82.24%) and 18.91% (range 0–113.26%) respectively (p = 0.540). Conclusions: The seven-year maintenance costs for a 2IOD is acceptable when the patient is regularly checked and professionally maintained. Most events are easily solvable chairside, but a few patients required more expensive interventions, regardless of the type of attachment used.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Open Dentistry Journal
Open Dentistry Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.00
自引率
0.00%
发文量
86
期刊最新文献
Calculus as a Risk Factor for Periodontal Disease: Narrative Review on Treatment Indications When the Response to Scaling and Root Planing Is Inadequate. Caries Experience and Treatment Needs in Urban and Rural Environments in School-Age Children from Three Provinces of Ecuador: A Cross-Sectional Study Cannabidiol in Dentistry: A Scoping Review Effectiveness of 38% Silver Diamine Fluoride in Reducing Dentine Hypersensitivity on Exposed Root Surface in Older Chinese Adults: Study Protocol for a Randomised Double-Blind Study Challenges and Opportunities for Dental Education from COVID-19
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1