{"title":"高通量电生理使用全自动,多路记录系统","authors":"J. D. Trumbull, E. Maslana, D. Mckenna, Thomas A. Nemcek, W. Niforatos, Jeffrey Y. Pan, A. Parihar, C. Shieh, Julie A. Wilkins, C. Briggs, D. Bertrand","doi":"10.1080/10606820308252","DOIUrl":null,"url":null,"abstract":"The drug discovery process centers around finding and optimizing novel compounds active at therapeutic targets. This process involves direct and indirect measures of how compounds affect the behavior of the target in question. The sheer number of compounds that must be tested poses problems for classes of ion channel targets for which direct functional measurements (e.g., traditional patch-clamping) are too cumbersome and indirect measurements (e.g., Ca(2+)-sensitive dyes) lack sufficient sensitivity or require unacceptable compromises. We present an optimized process for obtaining large numbers of direct electrophysiological measurements (two-electrode voltage-clamp) from Xenopus oocytes using a combination of automated oocyte handling, efficient and flexible liquid delivery, parallel operation, and powerful integrated data analysis. These improvements have had a marked impact, increasing the contribution electrophysiology makes in optimizing lead compound series and the discovery of new ones. The design of the system is detailed along with examples of data generated in support of lead optimization and discovery.","PeriodicalId":20928,"journal":{"name":"Receptors & channels","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"High Throughput Electrophysiology Using a Fully Automated, Multiplexed Recording System\",\"authors\":\"J. D. Trumbull, E. Maslana, D. Mckenna, Thomas A. Nemcek, W. Niforatos, Jeffrey Y. Pan, A. Parihar, C. Shieh, Julie A. Wilkins, C. Briggs, D. Bertrand\",\"doi\":\"10.1080/10606820308252\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The drug discovery process centers around finding and optimizing novel compounds active at therapeutic targets. This process involves direct and indirect measures of how compounds affect the behavior of the target in question. The sheer number of compounds that must be tested poses problems for classes of ion channel targets for which direct functional measurements (e.g., traditional patch-clamping) are too cumbersome and indirect measurements (e.g., Ca(2+)-sensitive dyes) lack sufficient sensitivity or require unacceptable compromises. We present an optimized process for obtaining large numbers of direct electrophysiological measurements (two-electrode voltage-clamp) from Xenopus oocytes using a combination of automated oocyte handling, efficient and flexible liquid delivery, parallel operation, and powerful integrated data analysis. These improvements have had a marked impact, increasing the contribution electrophysiology makes in optimizing lead compound series and the discovery of new ones. The design of the system is detailed along with examples of data generated in support of lead optimization and discovery.\",\"PeriodicalId\":20928,\"journal\":{\"name\":\"Receptors & channels\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Receptors & channels\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/10606820308252\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Receptors & channels","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10606820308252","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

摘要

药物发现过程的中心是发现和优化在治疗靶点上有活性的新化合物。这个过程包括直接和间接测量化合物如何影响目标的行为。必须测试的化合物的绝对数量对离子通道目标的类别提出了问题,这些目标的直接功能测量(例如,传统的贴片夹紧)过于繁琐,间接测量(例如,Ca(2+)敏感染料)缺乏足够的灵敏度或需要不可接受的妥协。我们提出了一种优化的方法,利用自动卵母细胞处理、高效灵活的液体输送、并行操作和强大的集成数据分析,从非洲爪蟾卵母细胞中获得大量直接电生理测量(双电极电压钳)。这些改进产生了显著的影响,增加了电生理学在优化先导化合物系列和发现新化合物方面的贡献。详细介绍了系统的设计,并提供了支持潜在客户优化和发现的数据示例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High Throughput Electrophysiology Using a Fully Automated, Multiplexed Recording System
The drug discovery process centers around finding and optimizing novel compounds active at therapeutic targets. This process involves direct and indirect measures of how compounds affect the behavior of the target in question. The sheer number of compounds that must be tested poses problems for classes of ion channel targets for which direct functional measurements (e.g., traditional patch-clamping) are too cumbersome and indirect measurements (e.g., Ca(2+)-sensitive dyes) lack sufficient sensitivity or require unacceptable compromises. We present an optimized process for obtaining large numbers of direct electrophysiological measurements (two-electrode voltage-clamp) from Xenopus oocytes using a combination of automated oocyte handling, efficient and flexible liquid delivery, parallel operation, and powerful integrated data analysis. These improvements have had a marked impact, increasing the contribution electrophysiology makes in optimizing lead compound series and the discovery of new ones. The design of the system is detailed along with examples of data generated in support of lead optimization and discovery.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Desensitization of muscarinic receptors. Comparison of the pharmacological properties of rat Na(V)1.8 with rat Na(V)1.2a and human Na(V)1.5 voltage-gated sodium channel subtypes using a membrane potential sensitive dye and FLIPR. Comparison of modulation of Kv1.3 channel by two receptor tyrosine kinases in olfactory bulb neurons of rodents. Production of the human D2S receptor in the methylotrophic yeast P. pastoris. G-protein coupled receptors as allosteric machines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1