M. Jin, Tae‐Hoon Kim, Ki-Woon Kang, H. Yu, J. Uhm, B. Joung, Moon‐Hyoung Lee, Eosu Kim, H. Pak
{"title":"房颤导管消融改善1年随访认知功能,尤其是认知功能受损患者。","authors":"M. Jin, Tae‐Hoon Kim, Ki-Woon Kang, H. Yu, J. Uhm, B. Joung, Moon‐Hyoung Lee, Eosu Kim, H. Pak","doi":"10.1161/CIRCEP.119.007197","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nAlthough atrial fibrillation (AF) has a risk of cognitive dysfunction, it is not clear whether AF catheter ablation improves or worsens cognitive function. This prospective case-control study sought to assess the 1-year serial changes in the cognitive function with or without AF catheter ablation.\n\n\nMETHODS\nWe evaluated the Montreal Cognitive Assessment score in 308 patients (71.4% male, 60.6±9.1 years of age, 34.1% persistent AF) who underwent AF ablation (ablation group) and 50 AF patients on medical therapy who met the same indication for AF ablation (control group), at baseline and 3 and 12 months after enrollment. Cognitive impairment was defined as a published cutoff score of <23 points. To exclude any learning effects, we used the practice-adjusted reliable change index for assessing the cognitive changes.\n\n\nRESULTS\nPreablation cognitive impairment was detected in 18.5% (57/308). The Montreal Cognitive Assessment score significantly improved 1 year after radiofrequency catheter ablation in both overall ablation group (24.9±2.9-26.4±2.5; P<0.001) and the propensity-matched ablation group (25.4±2.4-26.5±2.3; P<0.001), but not in the control group (25.4±2.5-24.8±2.5; P=0.012). Preablation cognitive impairment (odds ratio, 13.70; 95% CI, 4.83-38.87; P<0.001) was independently associated with an improvement in the 1-year post-ablation cognitive function. In the reliable change index analyses, 94.7% of propensity-matched ablation group showed an improved/stable cognitive function at the 1-year follow-up.\n\n\nCONCLUSIONS\nCatheter ablation of AF, at least, does not deteriorate the cognitive function, but rather improves the performance on 1-year follow-up neurocognitive tests, especially in patients with a preablation cognitive impairment.","PeriodicalId":10167,"journal":{"name":"Circulation: Arrhythmia and Electrophysiology","volume":"70 1","pages":"e007197"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"74","resultStr":"{\"title\":\"Atrial Fibrillation Catheter Ablation Improves 1-Year Follow-Up Cognitive Function, Especially in Patients With Impaired Cognitive Function.\",\"authors\":\"M. Jin, Tae‐Hoon Kim, Ki-Woon Kang, H. Yu, J. Uhm, B. Joung, Moon‐Hyoung Lee, Eosu Kim, H. Pak\",\"doi\":\"10.1161/CIRCEP.119.007197\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BACKGROUND\\nAlthough atrial fibrillation (AF) has a risk of cognitive dysfunction, it is not clear whether AF catheter ablation improves or worsens cognitive function. This prospective case-control study sought to assess the 1-year serial changes in the cognitive function with or without AF catheter ablation.\\n\\n\\nMETHODS\\nWe evaluated the Montreal Cognitive Assessment score in 308 patients (71.4% male, 60.6±9.1 years of age, 34.1% persistent AF) who underwent AF ablation (ablation group) and 50 AF patients on medical therapy who met the same indication for AF ablation (control group), at baseline and 3 and 12 months after enrollment. Cognitive impairment was defined as a published cutoff score of <23 points. To exclude any learning effects, we used the practice-adjusted reliable change index for assessing the cognitive changes.\\n\\n\\nRESULTS\\nPreablation cognitive impairment was detected in 18.5% (57/308). The Montreal Cognitive Assessment score significantly improved 1 year after radiofrequency catheter ablation in both overall ablation group (24.9±2.9-26.4±2.5; P<0.001) and the propensity-matched ablation group (25.4±2.4-26.5±2.3; P<0.001), but not in the control group (25.4±2.5-24.8±2.5; P=0.012). Preablation cognitive impairment (odds ratio, 13.70; 95% CI, 4.83-38.87; P<0.001) was independently associated with an improvement in the 1-year post-ablation cognitive function. In the reliable change index analyses, 94.7% of propensity-matched ablation group showed an improved/stable cognitive function at the 1-year follow-up.\\n\\n\\nCONCLUSIONS\\nCatheter ablation of AF, at least, does not deteriorate the cognitive function, but rather improves the performance on 1-year follow-up neurocognitive tests, especially in patients with a preablation cognitive impairment.\",\"PeriodicalId\":10167,\"journal\":{\"name\":\"Circulation: Arrhythmia and Electrophysiology\",\"volume\":\"70 1\",\"pages\":\"e007197\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"74\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Circulation: Arrhythmia and Electrophysiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1161/CIRCEP.119.007197\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation: Arrhythmia and Electrophysiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1161/CIRCEP.119.007197","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 74

摘要

背景:虽然心房颤动(AF)有认知功能障碍的风险,但心房颤动导管消融是改善还是恶化认知功能尚不清楚。这项前瞻性病例对照研究旨在评估心房颤动导管消融前后1年认知功能的连续变化。方法我们对308例房颤消融患者(71.4%男性,60.6±9.1岁,34.1%持续性房颤)(消融组)和50例符合房颤消融指征的药物治疗房颤患者(对照组)在基线和入组后3个月和12个月的蒙特利尔认知评估评分进行评估。认知障碍定义为公布的截止分数<23分。为了排除任何学习影响,我们使用实践调整的可靠变化指数来评估认知变化。结果18.5%(57/308)存在弥散性消融认知障碍。两组患者射频导管消融后1年蒙特利尔认知评估评分均显著提高(24.9±2.9 ~ 26.4±2.5;P<0.001)和倾向匹配消融组(25.4±2.4 ~ 26.5±2.3;P<0.001),对照组为25.4±2.5 ~ 24.8±2.5;P = 0.012)。消融前认知障碍(优势比,13.70;95% ci, 4.83-38.87;P<0.001)与消融后1年认知功能改善独立相关。在可靠的变化指数分析中,94.7%的倾向匹配消融组在1年随访中表现出改善/稳定的认知功能。结论AF导管消融至少不会使认知功能恶化,反而会提高1年随访神经认知测试的表现,尤其是消融前存在认知功能障碍的患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Atrial Fibrillation Catheter Ablation Improves 1-Year Follow-Up Cognitive Function, Especially in Patients With Impaired Cognitive Function.
BACKGROUND Although atrial fibrillation (AF) has a risk of cognitive dysfunction, it is not clear whether AF catheter ablation improves or worsens cognitive function. This prospective case-control study sought to assess the 1-year serial changes in the cognitive function with or without AF catheter ablation. METHODS We evaluated the Montreal Cognitive Assessment score in 308 patients (71.4% male, 60.6±9.1 years of age, 34.1% persistent AF) who underwent AF ablation (ablation group) and 50 AF patients on medical therapy who met the same indication for AF ablation (control group), at baseline and 3 and 12 months after enrollment. Cognitive impairment was defined as a published cutoff score of <23 points. To exclude any learning effects, we used the practice-adjusted reliable change index for assessing the cognitive changes. RESULTS Preablation cognitive impairment was detected in 18.5% (57/308). The Montreal Cognitive Assessment score significantly improved 1 year after radiofrequency catheter ablation in both overall ablation group (24.9±2.9-26.4±2.5; P<0.001) and the propensity-matched ablation group (25.4±2.4-26.5±2.3; P<0.001), but not in the control group (25.4±2.5-24.8±2.5; P=0.012). Preablation cognitive impairment (odds ratio, 13.70; 95% CI, 4.83-38.87; P<0.001) was independently associated with an improvement in the 1-year post-ablation cognitive function. In the reliable change index analyses, 94.7% of propensity-matched ablation group showed an improved/stable cognitive function at the 1-year follow-up. CONCLUSIONS Catheter ablation of AF, at least, does not deteriorate the cognitive function, but rather improves the performance on 1-year follow-up neurocognitive tests, especially in patients with a preablation cognitive impairment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Coronary Sinus Metabolite 12,13-diHOME Is a Novel Biomarker for Left Atrial Remodeling in Patients With Atrial Fibrillation Impact of Contact Force on Pulsed Field Ablation Outcomes Using Focal Point Catheter Characteristics of Right-Sided Accessory Pathways Associated With Right Cardiac Veins Prognostic Impact of Sinus Rhythm in Atrial Fibrillation Patients: Separating Rhythm Outcomes From Randomized Strategy Findings From the CABANA Trial Trends Favoring an Anatomical Approach to Radiofrequency Catheter Ablation of Idiopathic Ventricular Arrhythmias Originating From the Left Ventricular Summit
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1