东莨菪碱一声喉咙炎:在脊柱手术后的印度问题和技术问题:隐姓氏和技术问题

IF 0.6 4区 医学 Q4 SURGERY European Surgery-Acta Chirurgica Austriaca Pub Date : 2008-10-09 DOI:10.1046/j.1563-2563.2002.02074.x
C. Boldin, F. Fankhauser, F. J. Seibert, J. M. Passler
{"title":"东莨菪碱一声喉咙炎:在脊柱手术后的印度问题和技术问题:隐姓氏和技术问题","authors":"C. Boldin,&nbsp;F. Fankhauser,&nbsp;F. J. Seibert,&nbsp;J. M. Passler","doi":"10.1046/j.1563-2563.2002.02074.x","DOIUrl":null,"url":null,"abstract":"<p><b>Summary:</b> <span>Background</span>: Postoperative complaints after total knee arthroplasty range from restriction in range of motion, recurrent swelling, and soft tissue impingement through to prosthesis failure with no obvious radiological abnormality. This study looks at the indications and technical problems of arthroscopy in the treatment of symptomatic total knee arthroplasty. \n\n<span>Methods</span>: Fourteen arthroscopies were performed between 3 days and 10 years following total knee arthroplasty. Six of these cases presented significantly decreased range of motion, four had proximal medial joint line pain, two had pain with no obvious cause, one had a suspected patella incongruence with metal-back contact, and one case had a postoperative haemarthrosis. \n\n<span>Results</span>: Arthroscopy revealed adhesions and intra-articular fibrous bands resulting in incongruence of the patellofemoral joint and decreased range of motion. Medial compartment pain was due to pseudomeniscal hypertrophic villous synovium. In one case, the pain was due to chronic infection and open synovectomy was undertaken. A fracture of the polyethylene inlet was found by arthroscopy in one case. The suspected patella malalignment with metal-back contact was confirmed by arthroscopy. Technical problems encompassed mirror images, the possibility of damaging the components by arthroscopic manipulation, and the variants of prosthesis. \n\n<span>Conclusions</span>: Arthroscopy of total knee arthroplasties is a good minimally invasive method for the diagnosis and treatment of postoperative dysfunction, such as arthrofibrosis, soft tissue impingement, patella instability, infection, breakdown of implants and haemarthrosis.</p>","PeriodicalId":50475,"journal":{"name":"European Surgery-Acta Chirurgica Austriaca","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2008-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1046/j.1563-2563.2002.02074.x","citationCount":"4","resultStr":"{\"title\":\"Arthroscopy of Total Knee Arthroplasties: Indications and Technical Problems\\n Arthroskopie nach Knietotalendoprothesen: Indikationsstellung und technische Probleme\",\"authors\":\"C. Boldin,&nbsp;F. Fankhauser,&nbsp;F. J. Seibert,&nbsp;J. M. Passler\",\"doi\":\"10.1046/j.1563-2563.2002.02074.x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><b>Summary:</b> <span>Background</span>: Postoperative complaints after total knee arthroplasty range from restriction in range of motion, recurrent swelling, and soft tissue impingement through to prosthesis failure with no obvious radiological abnormality. This study looks at the indications and technical problems of arthroscopy in the treatment of symptomatic total knee arthroplasty. \\n\\n<span>Methods</span>: Fourteen arthroscopies were performed between 3 days and 10 years following total knee arthroplasty. Six of these cases presented significantly decreased range of motion, four had proximal medial joint line pain, two had pain with no obvious cause, one had a suspected patella incongruence with metal-back contact, and one case had a postoperative haemarthrosis. \\n\\n<span>Results</span>: Arthroscopy revealed adhesions and intra-articular fibrous bands resulting in incongruence of the patellofemoral joint and decreased range of motion. Medial compartment pain was due to pseudomeniscal hypertrophic villous synovium. In one case, the pain was due to chronic infection and open synovectomy was undertaken. A fracture of the polyethylene inlet was found by arthroscopy in one case. The suspected patella malalignment with metal-back contact was confirmed by arthroscopy. Technical problems encompassed mirror images, the possibility of damaging the components by arthroscopic manipulation, and the variants of prosthesis. \\n\\n<span>Conclusions</span>: Arthroscopy of total knee arthroplasties is a good minimally invasive method for the diagnosis and treatment of postoperative dysfunction, such as arthrofibrosis, soft tissue impingement, patella instability, infection, breakdown of implants and haemarthrosis.</p>\",\"PeriodicalId\":50475,\"journal\":{\"name\":\"European Surgery-Acta Chirurgica Austriaca\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2008-10-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1046/j.1563-2563.2002.02074.x\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Surgery-Acta Chirurgica Austriaca\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1046/j.1563-2563.2002.02074.x\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Surgery-Acta Chirurgica Austriaca","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1046/j.1563-2563.2002.02074.x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 4

摘要

摘要:背景:全膝关节置换术后的主诉从活动范围受限、反复肿胀、软组织撞击到假体失效,无明显影像学异常。本研究着眼于关节镜治疗症状性全膝关节置换术的适应症和技术问题。方法:在全膝关节置换术后3天至10年内进行了14次关节镜检查。其中6例表现为活动范围明显减小,4例为关节近内侧线疼痛,2例为无明显原因的疼痛,1例疑似髌骨与金属背接触不一致,1例为术后关节出血。结果:关节镜检查显示粘连和关节内纤维带导致髌股关节不一致和活动范围减小。内侧筋膜室疼痛是由假膝肥大绒毛滑膜引起的。在一个病例中,疼痛是由于慢性感染和开腹滑膜切除术。其中一例经关节镜检查发现聚乙烯入口骨折。关节镜证实疑似髌骨错位伴金属背接触。技术问题包括镜像,关节镜操作损坏部件的可能性,以及假体的变体。结论:全膝关节置换术中关节镜对关节纤维化、软组织撞击、髌骨不稳、感染、假体破裂、关节血肿等术后功能障碍是一种良好的微创诊断和治疗方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Arthroscopy of Total Knee Arthroplasties: Indications and Technical Problems Arthroskopie nach Knietotalendoprothesen: Indikationsstellung und technische Probleme

Summary: Background: Postoperative complaints after total knee arthroplasty range from restriction in range of motion, recurrent swelling, and soft tissue impingement through to prosthesis failure with no obvious radiological abnormality. This study looks at the indications and technical problems of arthroscopy in the treatment of symptomatic total knee arthroplasty. Methods: Fourteen arthroscopies were performed between 3 days and 10 years following total knee arthroplasty. Six of these cases presented significantly decreased range of motion, four had proximal medial joint line pain, two had pain with no obvious cause, one had a suspected patella incongruence with metal-back contact, and one case had a postoperative haemarthrosis. Results: Arthroscopy revealed adhesions and intra-articular fibrous bands resulting in incongruence of the patellofemoral joint and decreased range of motion. Medial compartment pain was due to pseudomeniscal hypertrophic villous synovium. In one case, the pain was due to chronic infection and open synovectomy was undertaken. A fracture of the polyethylene inlet was found by arthroscopy in one case. The suspected patella malalignment with metal-back contact was confirmed by arthroscopy. Technical problems encompassed mirror images, the possibility of damaging the components by arthroscopic manipulation, and the variants of prosthesis. Conclusions: Arthroscopy of total knee arthroplasties is a good minimally invasive method for the diagnosis and treatment of postoperative dysfunction, such as arthrofibrosis, soft tissue impingement, patella instability, infection, breakdown of implants and haemarthrosis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
36
审稿时长
6-12 weeks
期刊介绍: The journal European Surgery – Acta Chirurgica Austriaca focuses on general surgery, endocrine surgery, thoracic surgery, heart and vascular surgery. Special features include new surgical and endoscopic techniques such as minimally invasive surgery, robot surgery, and advances in surgery-related biotechnology and surgical oncology. The journal especially addresses benign and malignant esophageal diseases, i.e. achalasia, gastroesophageal reflux disease, Barrett’s esophagus, and esophageal adenocarcinoma. In keeping with modern healthcare requirements, the journal’s scope includes inter- and multidisciplinary disease management (diagnosis, therapy and surveillance).
期刊最新文献
Remote training and evaluation of a simulator-based training course for complex endovascular procedures. Training in vascular trauma surgery for non-vascular surgeons: Vascular trauma surgery skills course. Coping with a lack of evidence: living-donor kidney transplantation in the initial phase of the SARS-CoV-2 pandemic. 63rd Annual Meeting of the Austrian Society of Surgery. Delayed presentation of inflammatory breast carcinoma during the COVID-19 pandemic.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1