填补了肿瘤-间质比显微分析和自动分析之间的空白

S. Sarvepalli, P. Lal, Afrin N. Kamal, A. Garber, J. McMichael, G. Morris-Stiff, J. Vargo, M. Rothberg, Maged Rizk, C. Burke
{"title":"填补了肿瘤-间质比显微分析和自动分析之间的空白","authors":"S. Sarvepalli, P. Lal, Afrin N. Kamal, A. Garber, J. McMichael, G. Morris-Stiff, J. Vargo, M. Rothberg, Maged Rizk, C. Burke","doi":"10.30476/ACRR.2020.46438","DOIUrl":null,"url":null,"abstract":"Determining the tumor-stroma ratio (TSR) using a conventional microscope is an easy to apply and highly reproducible method. Due to digitalization in the pathology workflow, the demand for automated analysis of the TSR method is rising. However, the process of automation is rather time consuming and needs validation before implementation in daily practice. In addition, international studies ask for exchange of digital images instead of the actual slides. This calls for an alternative digital scoring method. This brief report describes the pitfalls of analyzing the TSR using digital images and proposes essential adaptations to create a standardized and reproducible scoring protocol. By using a circular annotation to mimic the microscopic method, these pitfalls can be avoided. Scoring the TSR digitally using a circular annotation does not take much additional effort compared to the microscopic method. When a fixed size of the annotation is saved, new cases can be scored in less than two minutes. With this brief report we propose an adjusted method for scoring the TSR on digital images to fill the gap between microscopically and automated scoring of the TSR. In addition, it opens the opportunity for application in daily diagnostics.","PeriodicalId":8370,"journal":{"name":"Annals of Colorectal Research","volume":"19 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Filling the gap between microscopic and automated analysis of the tumor-stroma ratio\",\"authors\":\"S. Sarvepalli, P. Lal, Afrin N. Kamal, A. Garber, J. McMichael, G. Morris-Stiff, J. Vargo, M. Rothberg, Maged Rizk, C. Burke\",\"doi\":\"10.30476/ACRR.2020.46438\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Determining the tumor-stroma ratio (TSR) using a conventional microscope is an easy to apply and highly reproducible method. Due to digitalization in the pathology workflow, the demand for automated analysis of the TSR method is rising. However, the process of automation is rather time consuming and needs validation before implementation in daily practice. In addition, international studies ask for exchange of digital images instead of the actual slides. This calls for an alternative digital scoring method. This brief report describes the pitfalls of analyzing the TSR using digital images and proposes essential adaptations to create a standardized and reproducible scoring protocol. By using a circular annotation to mimic the microscopic method, these pitfalls can be avoided. Scoring the TSR digitally using a circular annotation does not take much additional effort compared to the microscopic method. When a fixed size of the annotation is saved, new cases can be scored in less than two minutes. With this brief report we propose an adjusted method for scoring the TSR on digital images to fill the gap between microscopically and automated scoring of the TSR. In addition, it opens the opportunity for application in daily diagnostics.\",\"PeriodicalId\":8370,\"journal\":{\"name\":\"Annals of Colorectal Research\",\"volume\":\"19 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Colorectal Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30476/ACRR.2020.46438\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Colorectal Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30476/ACRR.2020.46438","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

利用常规显微镜测定肿瘤间质比(TSR)是一种易于应用且重复性高的方法。由于病理工作流程的数字化,对TSR方法自动化分析的需求正在上升。然而,自动化的过程是相当耗时的,并且需要在日常实践中实施之前进行验证。此外,国际研究要求交换数字图像,而不是实际的幻灯片。这就需要另一种数字评分方法。这篇简短的报告描述了使用数字图像分析TSR的陷阱,并提出了创建标准化和可重复的评分协议的基本调整。通过使用循环注释来模拟微观方法,可以避免这些缺陷。与微观方法相比,使用循环注释对TSR进行数字化评分并不需要太多额外的努力。当保存固定大小的注释时,新案例可以在不到两分钟的时间内得分。在这篇简短的报告中,我们提出了一种在数字图像上进行TSR评分的调整方法,以填补TSR显微评分和自动评分之间的空白。此外,它还为日常诊断提供了应用机会。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Filling the gap between microscopic and automated analysis of the tumor-stroma ratio
Determining the tumor-stroma ratio (TSR) using a conventional microscope is an easy to apply and highly reproducible method. Due to digitalization in the pathology workflow, the demand for automated analysis of the TSR method is rising. However, the process of automation is rather time consuming and needs validation before implementation in daily practice. In addition, international studies ask for exchange of digital images instead of the actual slides. This calls for an alternative digital scoring method. This brief report describes the pitfalls of analyzing the TSR using digital images and proposes essential adaptations to create a standardized and reproducible scoring protocol. By using a circular annotation to mimic the microscopic method, these pitfalls can be avoided. Scoring the TSR digitally using a circular annotation does not take much additional effort compared to the microscopic method. When a fixed size of the annotation is saved, new cases can be scored in less than two minutes. With this brief report we propose an adjusted method for scoring the TSR on digital images to fill the gap between microscopically and automated scoring of the TSR. In addition, it opens the opportunity for application in daily diagnostics.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Role of endoplasmic reticulum metallo protease 1 on Autophagy Pathway in HCT-116 Colorectal Cancer Cell Line ORAL BACTERIA AND COLORECTAL PATHOLOGY Technique of Ghost (Khatith) Ileostomy-How I Do It? Collagenous Enteritis – An Alternative Cause of Malabsorptive Enteropathy SIMPLE ANAL FISTULA: CLINICAL CRITERIA FOR DIAGNOSIS AND LOCAL ANESTHESIA WITH CONSCIOUS SEDATION FOR SURGERY - AN OBSERVATIONAL STUDY
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1