{"title":"建立了高效液相色谱法测定制剂中雷地帕韦和索非布韦含量的新方法","authors":"K. Swathi, P. V. Rao, N. Rao","doi":"10.33974/ijrpca.v1i3.113","DOIUrl":null,"url":null,"abstract":"A simple, Accurate, precise method was developed for the simultaneous estimation of the Sofosbuvir and Ledipasvir in Tablet dosage form. Chromatogram was run through Std Discovery C8 150 x 4.6 mm, 5m. Mobile phase containing Buffer 0.1% OPA: Acetonitrile taken in the ratio 60:40 was pumped through column at a flow rate of 1 ml/min. Buffer used in this method was 0.1% OPA buffer. Temperature was maintained at 30°C. Optimized wavelength selected was 260 nm. Retention time of Sofosbuvir and Ledipasvir were found to be 2.367 min and 3.436 min. %RSD of the Sofosbuvir and Ledipasvir were and found to be 0.6 and 0.5 respectively. %Recovery was obtained as 99.61% and 99.80% for Sofosbuvir and Ledipasvir respectively. LOD, LOQ values obtained from regression equations of Sofosbuvir and Ledipasvir were 0.67, 2.02 and 0.70, 2.12 respectively. Regression equation of Sofosbuvir is y = 4266.x + 7700, and y = 4861.x + 2656.of Ledipasvir. Retention times were decreased and run time was decreased, so the method developed was simple and economical that can be adopted in regular Quality control test in Industries.","PeriodicalId":14207,"journal":{"name":"International Journal of Research In Pharmaceutical Chemistry and Analysis","volume":"332 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A new analytical method for determination of ledipasvir and sofosbuvir in pharmaceutical formulations by HPLC method\",\"authors\":\"K. Swathi, P. V. Rao, N. Rao\",\"doi\":\"10.33974/ijrpca.v1i3.113\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A simple, Accurate, precise method was developed for the simultaneous estimation of the Sofosbuvir and Ledipasvir in Tablet dosage form. Chromatogram was run through Std Discovery C8 150 x 4.6 mm, 5m. Mobile phase containing Buffer 0.1% OPA: Acetonitrile taken in the ratio 60:40 was pumped through column at a flow rate of 1 ml/min. Buffer used in this method was 0.1% OPA buffer. Temperature was maintained at 30°C. Optimized wavelength selected was 260 nm. Retention time of Sofosbuvir and Ledipasvir were found to be 2.367 min and 3.436 min. %RSD of the Sofosbuvir and Ledipasvir were and found to be 0.6 and 0.5 respectively. %Recovery was obtained as 99.61% and 99.80% for Sofosbuvir and Ledipasvir respectively. LOD, LOQ values obtained from regression equations of Sofosbuvir and Ledipasvir were 0.67, 2.02 and 0.70, 2.12 respectively. Regression equation of Sofosbuvir is y = 4266.x + 7700, and y = 4861.x + 2656.of Ledipasvir. Retention times were decreased and run time was decreased, so the method developed was simple and economical that can be adopted in regular Quality control test in Industries.\",\"PeriodicalId\":14207,\"journal\":{\"name\":\"International Journal of Research In Pharmaceutical Chemistry and Analysis\",\"volume\":\"332 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Research In Pharmaceutical Chemistry and Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33974/ijrpca.v1i3.113\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Research In Pharmaceutical Chemistry and Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33974/ijrpca.v1i3.113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A new analytical method for determination of ledipasvir and sofosbuvir in pharmaceutical formulations by HPLC method
A simple, Accurate, precise method was developed for the simultaneous estimation of the Sofosbuvir and Ledipasvir in Tablet dosage form. Chromatogram was run through Std Discovery C8 150 x 4.6 mm, 5m. Mobile phase containing Buffer 0.1% OPA: Acetonitrile taken in the ratio 60:40 was pumped through column at a flow rate of 1 ml/min. Buffer used in this method was 0.1% OPA buffer. Temperature was maintained at 30°C. Optimized wavelength selected was 260 nm. Retention time of Sofosbuvir and Ledipasvir were found to be 2.367 min and 3.436 min. %RSD of the Sofosbuvir and Ledipasvir were and found to be 0.6 and 0.5 respectively. %Recovery was obtained as 99.61% and 99.80% for Sofosbuvir and Ledipasvir respectively. LOD, LOQ values obtained from regression equations of Sofosbuvir and Ledipasvir were 0.67, 2.02 and 0.70, 2.12 respectively. Regression equation of Sofosbuvir is y = 4266.x + 7700, and y = 4861.x + 2656.of Ledipasvir. Retention times were decreased and run time was decreased, so the method developed was simple and economical that can be adopted in regular Quality control test in Industries.