{"title":"2011 - 2014年爱荷华州晶体硅和非晶硅光伏系统性能分析","authors":"A. A. Shishavan, Eric C. Foresman, F. Toor","doi":"10.1109/PVSC.2016.7750124","DOIUrl":null,"url":null,"abstract":"Iowa City is in the humid continental climate zone and the goal of this paper is to provide a thorough system performance analysis for PV systems installed in this climate zone. In this work we present the performance analysis of two photovoltaic (PV) systems installed at The University of Iowa in mid-2011. We analyze the system performance from mid-2011 to 2014. First system is a 39 kW-DC building-integrated amorphous silicon (a-Si) PV array. Second system is a 48.1 kW-DC solar charging station based on multicrystalline modules. We use National Renewable Energy Laboratory's System Advisor Model for the PV system performance analysis of the two systems and results of simulation are compared to measured energy yield. In addition, we compare PV system performance with the Iowa Energy Center Solar Calculator (IEC-SC) model for the mc-Si PV system. Our analysis indicates that the SAM model, with correct modeling parameters results in ±20% error relative to measured data whereas the IEC-SC model almost always over estimates the energy yield.","PeriodicalId":6524,"journal":{"name":"2016 IEEE 43rd Photovoltaic Specialists Conference (PVSC)","volume":"3 1","pages":"2625-2630"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Performance analysis of crystalline silicon and amorphous silicon photovoltaic systems in Iowa: 2011 to 2014\",\"authors\":\"A. A. Shishavan, Eric C. Foresman, F. Toor\",\"doi\":\"10.1109/PVSC.2016.7750124\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Iowa City is in the humid continental climate zone and the goal of this paper is to provide a thorough system performance analysis for PV systems installed in this climate zone. In this work we present the performance analysis of two photovoltaic (PV) systems installed at The University of Iowa in mid-2011. We analyze the system performance from mid-2011 to 2014. First system is a 39 kW-DC building-integrated amorphous silicon (a-Si) PV array. Second system is a 48.1 kW-DC solar charging station based on multicrystalline modules. We use National Renewable Energy Laboratory's System Advisor Model for the PV system performance analysis of the two systems and results of simulation are compared to measured energy yield. In addition, we compare PV system performance with the Iowa Energy Center Solar Calculator (IEC-SC) model for the mc-Si PV system. Our analysis indicates that the SAM model, with correct modeling parameters results in ±20% error relative to measured data whereas the IEC-SC model almost always over estimates the energy yield.\",\"PeriodicalId\":6524,\"journal\":{\"name\":\"2016 IEEE 43rd Photovoltaic Specialists Conference (PVSC)\",\"volume\":\"3 1\",\"pages\":\"2625-2630\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 43rd Photovoltaic Specialists Conference (PVSC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PVSC.2016.7750124\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 43rd Photovoltaic Specialists Conference (PVSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PVSC.2016.7750124","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

爱荷华市位于湿润大陆性气候区,本文的目标是为在该气候区安装的光伏系统提供全面的系统性能分析。在这项工作中,我们展示了2011年年中安装在爱荷华大学的两个光伏(PV)系统的性能分析。我们分析了从2011年中期到2014年的系统性能。第一个系统是39千瓦直流建筑集成非晶硅(a- si)光伏阵列。第二个系统是基于多晶硅模块的48.1 kw直流太阳能充电站。我们使用国家可再生能源实验室的系统顾问模型对两个系统的光伏系统性能进行了分析,并将模拟结果与实测发电量进行了比较。此外,我们比较了光伏系统的性能与爱荷华能源中心太阳能计算器(IEC-SC)模型的mc-Si光伏系统。我们的分析表明,在正确的建模参数下,SAM模型相对于测量数据的误差为±20%,而IEC-SC模型几乎总是高估了发电量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance analysis of crystalline silicon and amorphous silicon photovoltaic systems in Iowa: 2011 to 2014
Iowa City is in the humid continental climate zone and the goal of this paper is to provide a thorough system performance analysis for PV systems installed in this climate zone. In this work we present the performance analysis of two photovoltaic (PV) systems installed at The University of Iowa in mid-2011. We analyze the system performance from mid-2011 to 2014. First system is a 39 kW-DC building-integrated amorphous silicon (a-Si) PV array. Second system is a 48.1 kW-DC solar charging station based on multicrystalline modules. We use National Renewable Energy Laboratory's System Advisor Model for the PV system performance analysis of the two systems and results of simulation are compared to measured energy yield. In addition, we compare PV system performance with the Iowa Energy Center Solar Calculator (IEC-SC) model for the mc-Si PV system. Our analysis indicates that the SAM model, with correct modeling parameters results in ±20% error relative to measured data whereas the IEC-SC model almost always over estimates the energy yield.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Boosting the efficiency of III-V/Si tandem solar cells Bandgap and carrier transport engineering of quantum confined mixed phase nanocrystalline/amorphous silicon Improving the radiation hardness of space solar cells via nanophotonic light trapping A comparison between two MPC algorithms for demand charge reduction in a real-world microgrid system Enhancing grain growth and boosting Voc in CZTSe absorber layers — Is Ge doping the answer?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1