{"title":"液压蓄能器状态监测系统。效率、生产率和质量的改进","authors":"Christian Nisters, F. Bauer, M. Brocker","doi":"10.25368/2020.83","DOIUrl":null,"url":null,"abstract":"This paper addresses the necessity of a correct hydraulic accumulator pre-charge pressure for the optimum performance and in some cases even the essential function of the corresponding hydraulic application. In this context HYDAC has developed a smart product for predictive monitoring of the pre-charge pressure without any need to do a measurement on the gas side of the accumulator – the p0-Guard. The paper gives an overview on the conventional way of checking the pre-charge pressure, the function of the monitoring device and points out the benefits of a predictive monitoring of the accumulator precharge pressure. The benefits are clearly depicted by an analytical view as well as on practical example.","PeriodicalId":74543,"journal":{"name":"Proceedings of the Future Technologies Conference (FTC) 2022. Volume 2. Future Technologies Conference (7th : 2022 : Vancouver, B.C.; Online)","volume":"118 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Condition monitoring systems for hydraulic accumulators – improvements in efficiency, productivity and quality\",\"authors\":\"Christian Nisters, F. Bauer, M. Brocker\",\"doi\":\"10.25368/2020.83\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper addresses the necessity of a correct hydraulic accumulator pre-charge pressure for the optimum performance and in some cases even the essential function of the corresponding hydraulic application. In this context HYDAC has developed a smart product for predictive monitoring of the pre-charge pressure without any need to do a measurement on the gas side of the accumulator – the p0-Guard. The paper gives an overview on the conventional way of checking the pre-charge pressure, the function of the monitoring device and points out the benefits of a predictive monitoring of the accumulator precharge pressure. The benefits are clearly depicted by an analytical view as well as on practical example.\",\"PeriodicalId\":74543,\"journal\":{\"name\":\"Proceedings of the Future Technologies Conference (FTC) 2022. Volume 2. Future Technologies Conference (7th : 2022 : Vancouver, B.C.; Online)\",\"volume\":\"118 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Future Technologies Conference (FTC) 2022. Volume 2. Future Technologies Conference (7th : 2022 : Vancouver, B.C.; Online)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25368/2020.83\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Future Technologies Conference (FTC) 2022. Volume 2. Future Technologies Conference (7th : 2022 : Vancouver, B.C.; Online)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25368/2020.83","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
本文讨论了正确的液压蓄能器预充压的必要性,以获得最佳的性能,在某些情况下甚至是相应液压应用的基本功能。在此背景下,HYDAC开发了一款智能产品,可预测监测预充压力,而无需对蓄能器的气体侧进行测量- p - guard。本文概述了预充压力的常规检测方法和监测装置的功能,指出了对蓄能器预充压力进行预测监测的好处。通过分析的观点和实际的例子清楚地描述了这些好处。
Condition monitoring systems for hydraulic accumulators – improvements in efficiency, productivity and quality
This paper addresses the necessity of a correct hydraulic accumulator pre-charge pressure for the optimum performance and in some cases even the essential function of the corresponding hydraulic application. In this context HYDAC has developed a smart product for predictive monitoring of the pre-charge pressure without any need to do a measurement on the gas side of the accumulator – the p0-Guard. The paper gives an overview on the conventional way of checking the pre-charge pressure, the function of the monitoring device and points out the benefits of a predictive monitoring of the accumulator precharge pressure. The benefits are clearly depicted by an analytical view as well as on practical example.