脉冲驱动形状和调谐对换能器宽带响应的影响

R. McKeighen
{"title":"脉冲驱动形状和调谐对换能器宽带响应的影响","authors":"R. McKeighen","doi":"10.1109/ULTSYM.1997.663308","DOIUrl":null,"url":null,"abstract":"The shape and symmetry of the pulser drive waveform and its interaction with the transducer and its tuning circuitry have a profound effect upon the pulse echo performance achievable from a medical transducer probe. Conventional wisdom has it that the shortest pulse obtainable, and subsequently the widest bandwidth achievable will come from the impulse response of the system. This study helps elucidate why an impulse generator may not always result in the shortest pulse and widest bandwidth. The pulse response is critically dependent upon the pulser drive symmetry, and its interaction with the reactance of the components making up the tuning topology. Unipolar pulses such as the spike impulse, or half wave square unipolar pulse drive, can create notches in the drive spectrum at the gold electrode that are deleterious, and significantly reduce available bandwidth. The transducer model used in this study is a 3.5 MHz 96 element sector phased array. In conjunction with a new innovative transducer acoustic design and optimized tuning, experimental results producing bandwidths of over 90% with clean, short pulse ringdown, have been achieved.","PeriodicalId":6369,"journal":{"name":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","volume":"30 1","pages":"1637-1642 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Influence of pulse drive shape and tuning on the broadband response of a transducer\",\"authors\":\"R. McKeighen\",\"doi\":\"10.1109/ULTSYM.1997.663308\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The shape and symmetry of the pulser drive waveform and its interaction with the transducer and its tuning circuitry have a profound effect upon the pulse echo performance achievable from a medical transducer probe. Conventional wisdom has it that the shortest pulse obtainable, and subsequently the widest bandwidth achievable will come from the impulse response of the system. This study helps elucidate why an impulse generator may not always result in the shortest pulse and widest bandwidth. The pulse response is critically dependent upon the pulser drive symmetry, and its interaction with the reactance of the components making up the tuning topology. Unipolar pulses such as the spike impulse, or half wave square unipolar pulse drive, can create notches in the drive spectrum at the gold electrode that are deleterious, and significantly reduce available bandwidth. The transducer model used in this study is a 3.5 MHz 96 element sector phased array. In conjunction with a new innovative transducer acoustic design and optimized tuning, experimental results producing bandwidths of over 90% with clean, short pulse ringdown, have been achieved.\",\"PeriodicalId\":6369,\"journal\":{\"name\":\"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)\",\"volume\":\"30 1\",\"pages\":\"1637-1642 vol.2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1997.663308\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1997.663308","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

脉冲发生器驱动波形的形状和对称性及其与换能器及其调谐电路的相互作用对医用换能器探头的脉冲回波性能有深远的影响。传统观点认为,可获得的最短脉冲以及随后可获得的最宽带宽将来自系统的脉冲响应。这项研究有助于解释为什么脉冲发生器不一定总是产生最短的脉冲和最宽的带宽。脉冲响应严重依赖于脉冲发生器驱动的对称性,以及它与组成调谐拓扑的元件的电抗的相互作用。单极脉冲,如尖峰脉冲或半波方单极脉冲驱动,可以在金电极的驱动光谱中产生有害的凹痕,并显着降低可用带宽。本研究中使用的换能器模型为3.5 MHz 96元扇形相控阵。结合一种新的创新换能器声学设计和优化调谐,实验结果产生了超过90%的带宽,干净,短脉冲衰减,已经实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of pulse drive shape and tuning on the broadband response of a transducer
The shape and symmetry of the pulser drive waveform and its interaction with the transducer and its tuning circuitry have a profound effect upon the pulse echo performance achievable from a medical transducer probe. Conventional wisdom has it that the shortest pulse obtainable, and subsequently the widest bandwidth achievable will come from the impulse response of the system. This study helps elucidate why an impulse generator may not always result in the shortest pulse and widest bandwidth. The pulse response is critically dependent upon the pulser drive symmetry, and its interaction with the reactance of the components making up the tuning topology. Unipolar pulses such as the spike impulse, or half wave square unipolar pulse drive, can create notches in the drive spectrum at the gold electrode that are deleterious, and significantly reduce available bandwidth. The transducer model used in this study is a 3.5 MHz 96 element sector phased array. In conjunction with a new innovative transducer acoustic design and optimized tuning, experimental results producing bandwidths of over 90% with clean, short pulse ringdown, have been achieved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Diamond wafer for SAW application High contrast images of defects in food package seals New properties of the SAW gas sensing Electromagnetic acoustic resonance for studying dislocation formation in polycrystalline pure copper during deformation A new design of ultrasonic air-coupled ribbon transducer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1