{"title":"污绝缘子闪络的动态电弧模型","authors":"S. Bessedik, H. Hadi","doi":"10.1109/CEIDP.2011.6232716","DOIUrl":null,"url":null,"abstract":"The importance of the research on insulator pollution has been increased considerably with the rise of the voltage of transmission lines. In order to determine the flashover behavior of polluted high voltage insulators and to identify to physical mechanisms that govern this phenomenon, the researchers have been brought to establish a modeling. In this study after presenting the theoretical and experimental open model, a dynamic arc model has been developed to calculate the flashover. The validity of the model was verified by comparing the computed results with the experimental results of previous researchers and good correlation has been shown.","PeriodicalId":6317,"journal":{"name":"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"27 1","pages":"550-554"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Dynamic arc model of the flashover of the polluted insulators\",\"authors\":\"S. Bessedik, H. Hadi\",\"doi\":\"10.1109/CEIDP.2011.6232716\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The importance of the research on insulator pollution has been increased considerably with the rise of the voltage of transmission lines. In order to determine the flashover behavior of polluted high voltage insulators and to identify to physical mechanisms that govern this phenomenon, the researchers have been brought to establish a modeling. In this study after presenting the theoretical and experimental open model, a dynamic arc model has been developed to calculate the flashover. The validity of the model was verified by comparing the computed results with the experimental results of previous researchers and good correlation has been shown.\",\"PeriodicalId\":6317,\"journal\":{\"name\":\"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"27 1\",\"pages\":\"550-554\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2011.6232716\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2011.6232716","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Dynamic arc model of the flashover of the polluted insulators
The importance of the research on insulator pollution has been increased considerably with the rise of the voltage of transmission lines. In order to determine the flashover behavior of polluted high voltage insulators and to identify to physical mechanisms that govern this phenomenon, the researchers have been brought to establish a modeling. In this study after presenting the theoretical and experimental open model, a dynamic arc model has been developed to calculate the flashover. The validity of the model was verified by comparing the computed results with the experimental results of previous researchers and good correlation has been shown.