PhD, FBCO, FAAO Michel Guillon , PhD, FBCO Jean Pierre Guillon , BSc Dipti Shah , MST Sylvie Bertrand , B Optom, FAAO Timothy Grant
{"title":"高Dκ RGP材料的体内润湿性","authors":"PhD, FBCO, FAAO Michel Guillon ,&nbsp;PhD, FBCO Jean Pierre Guillon ,&nbsp;BSc Dipti Shah ,&nbsp;MST Sylvie Bertrand ,&nbsp;B Optom, FAAO Timothy Grant","doi":"10.1016/S0141-7037(95)80043-3","DOIUrl":null,"url":null,"abstract":"<div><p>This study compared the <em>in vivo</em> wettability of four high <em>Dk</em> rigid gas permeable (RGP) materials (<em>Aquila, Menicon</em>, Super EX, Quantum 1 and Quantum 2). The study design was a double-masked right/left eye comparison of 6 months' duration where the lenses were worn on a daily-wear basis. It involved three experimental groups, each using Aquila in one eye and one of the other materials in the fellow eye. The main conclusions obtained are as follows: The <em>in vivo</em> intrinsic wettability, and its alteration during a 6-month period of wear, was similar for all four high <em>Dk</em> materials tested. The in vivo characteristics of these materials were not different from those of lower <em>Dk</em> materials, hence increasing <em>Dk</em> does not result in reduced wettability as suspected by some practitioners. <em>In vivo</em> wettability is highly patient dependent, and so its ongoing monitoring during routine practice is necessary for optimal patient management. <em>In vivo</em> wettability is affected by lens wear; after 6 months' wear the stability of the tear film at the front of the contact lens was significantly reduced and the level of surface contamination increased compared with dispensing. The notion of planned replacement should be extended to RGP contact lenses. Replacement frequencies of 6, or even 3 months would be of benefit for a significant number of patients.</p></div>","PeriodicalId":100842,"journal":{"name":"Journal of The British Contact Lens Association","volume":"18 1","pages":"Pages 9-15"},"PeriodicalIF":0.0000,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0141-7037(95)80043-3","citationCount":"9","resultStr":"{\"title\":\"In vivo wettability of high Dκ RGP materials\",\"authors\":\"PhD, FBCO, FAAO Michel Guillon ,&nbsp;PhD, FBCO Jean Pierre Guillon ,&nbsp;BSc Dipti Shah ,&nbsp;MST Sylvie Bertrand ,&nbsp;B Optom, FAAO Timothy Grant\",\"doi\":\"10.1016/S0141-7037(95)80043-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This study compared the <em>in vivo</em> wettability of four high <em>Dk</em> rigid gas permeable (RGP) materials (<em>Aquila, Menicon</em>, Super EX, Quantum 1 and Quantum 2). The study design was a double-masked right/left eye comparison of 6 months' duration where the lenses were worn on a daily-wear basis. It involved three experimental groups, each using Aquila in one eye and one of the other materials in the fellow eye. The main conclusions obtained are as follows: The <em>in vivo</em> intrinsic wettability, and its alteration during a 6-month period of wear, was similar for all four high <em>Dk</em> materials tested. The in vivo characteristics of these materials were not different from those of lower <em>Dk</em> materials, hence increasing <em>Dk</em> does not result in reduced wettability as suspected by some practitioners. <em>In vivo</em> wettability is highly patient dependent, and so its ongoing monitoring during routine practice is necessary for optimal patient management. <em>In vivo</em> wettability is affected by lens wear; after 6 months' wear the stability of the tear film at the front of the contact lens was significantly reduced and the level of surface contamination increased compared with dispensing. The notion of planned replacement should be extended to RGP contact lenses. Replacement frequencies of 6, or even 3 months would be of benefit for a significant number of patients.</p></div>\",\"PeriodicalId\":100842,\"journal\":{\"name\":\"Journal of The British Contact Lens Association\",\"volume\":\"18 1\",\"pages\":\"Pages 9-15\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S0141-7037(95)80043-3\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of The British Contact Lens Association\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0141703795800433\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The British Contact Lens Association","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0141703795800433","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本研究比较了四种高Dk刚性透气性(RGP)材料(Aquila, Menicon, Super EX, Quantum 1和Quantum 2)的体内润湿性。研究设计是双蒙面右眼/左眼比较,持续6个月,每天佩戴镜片。它涉及三个实验组,每个实验组在一只眼睛中使用Aquila,在另一只眼睛中使用另一种材料。得到的主要结论如下:四种高Dk材料的体内固有润湿性及其在6个月磨损期间的变化是相似的。这些材料的体内特性与低Dk材料没有什么不同,因此增加Dk不会像一些从业者所怀疑的那样导致润湿性降低。体内润湿性高度依赖于患者,因此在常规实践中对其进行持续监测对于最佳患者管理是必要的。体内润湿性受晶状体磨损的影响;佩戴6个月后,与配药相比,隐形眼镜前部泪膜的稳定性明显降低,表面污染程度增加。计划更换的概念应该扩展到RGP隐形眼镜。6个月,甚至3个月的更换频率对相当数量的患者是有益的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In vivo wettability of high Dκ RGP materials

This study compared the in vivo wettability of four high Dk rigid gas permeable (RGP) materials (Aquila, Menicon, Super EX, Quantum 1 and Quantum 2). The study design was a double-masked right/left eye comparison of 6 months' duration where the lenses were worn on a daily-wear basis. It involved three experimental groups, each using Aquila in one eye and one of the other materials in the fellow eye. The main conclusions obtained are as follows: The in vivo intrinsic wettability, and its alteration during a 6-month period of wear, was similar for all four high Dk materials tested. The in vivo characteristics of these materials were not different from those of lower Dk materials, hence increasing Dk does not result in reduced wettability as suspected by some practitioners. In vivo wettability is highly patient dependent, and so its ongoing monitoring during routine practice is necessary for optimal patient management. In vivo wettability is affected by lens wear; after 6 months' wear the stability of the tear film at the front of the contact lens was significantly reduced and the level of surface contamination increased compared with dispensing. The notion of planned replacement should be extended to RGP contact lenses. Replacement frequencies of 6, or even 3 months would be of benefit for a significant number of patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Announcement Editorial Editorial Board Editorial Notices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1