PhD, FBCO, FAAO Michel Guillon , PhD, FBCO Jean Pierre Guillon , BSc Dipti Shah , MST Sylvie Bertrand , B Optom, FAAO Timothy Grant
{"title":"高Dκ RGP材料的体内润湿性","authors":"PhD, FBCO, FAAO Michel Guillon , PhD, FBCO Jean Pierre Guillon , BSc Dipti Shah , MST Sylvie Bertrand , B Optom, FAAO Timothy Grant","doi":"10.1016/S0141-7037(95)80043-3","DOIUrl":null,"url":null,"abstract":"<div><p>This study compared the <em>in vivo</em> wettability of four high <em>Dk</em> rigid gas permeable (RGP) materials (<em>Aquila, Menicon</em>, Super EX, Quantum 1 and Quantum 2). The study design was a double-masked right/left eye comparison of 6 months' duration where the lenses were worn on a daily-wear basis. It involved three experimental groups, each using Aquila in one eye and one of the other materials in the fellow eye. The main conclusions obtained are as follows: The <em>in vivo</em> intrinsic wettability, and its alteration during a 6-month period of wear, was similar for all four high <em>Dk</em> materials tested. The in vivo characteristics of these materials were not different from those of lower <em>Dk</em> materials, hence increasing <em>Dk</em> does not result in reduced wettability as suspected by some practitioners. <em>In vivo</em> wettability is highly patient dependent, and so its ongoing monitoring during routine practice is necessary for optimal patient management. <em>In vivo</em> wettability is affected by lens wear; after 6 months' wear the stability of the tear film at the front of the contact lens was significantly reduced and the level of surface contamination increased compared with dispensing. The notion of planned replacement should be extended to RGP contact lenses. Replacement frequencies of 6, or even 3 months would be of benefit for a significant number of patients.</p></div>","PeriodicalId":100842,"journal":{"name":"Journal of The British Contact Lens Association","volume":"18 1","pages":"Pages 9-15"},"PeriodicalIF":0.0000,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0141-7037(95)80043-3","citationCount":"9","resultStr":"{\"title\":\"In vivo wettability of high Dκ RGP materials\",\"authors\":\"PhD, FBCO, FAAO Michel Guillon , PhD, FBCO Jean Pierre Guillon , BSc Dipti Shah , MST Sylvie Bertrand , B Optom, FAAO Timothy Grant\",\"doi\":\"10.1016/S0141-7037(95)80043-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This study compared the <em>in vivo</em> wettability of four high <em>Dk</em> rigid gas permeable (RGP) materials (<em>Aquila, Menicon</em>, Super EX, Quantum 1 and Quantum 2). The study design was a double-masked right/left eye comparison of 6 months' duration where the lenses were worn on a daily-wear basis. It involved three experimental groups, each using Aquila in one eye and one of the other materials in the fellow eye. The main conclusions obtained are as follows: The <em>in vivo</em> intrinsic wettability, and its alteration during a 6-month period of wear, was similar for all four high <em>Dk</em> materials tested. The in vivo characteristics of these materials were not different from those of lower <em>Dk</em> materials, hence increasing <em>Dk</em> does not result in reduced wettability as suspected by some practitioners. <em>In vivo</em> wettability is highly patient dependent, and so its ongoing monitoring during routine practice is necessary for optimal patient management. <em>In vivo</em> wettability is affected by lens wear; after 6 months' wear the stability of the tear film at the front of the contact lens was significantly reduced and the level of surface contamination increased compared with dispensing. The notion of planned replacement should be extended to RGP contact lenses. Replacement frequencies of 6, or even 3 months would be of benefit for a significant number of patients.</p></div>\",\"PeriodicalId\":100842,\"journal\":{\"name\":\"Journal of The British Contact Lens Association\",\"volume\":\"18 1\",\"pages\":\"Pages 9-15\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S0141-7037(95)80043-3\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of The British Contact Lens Association\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0141703795800433\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The British Contact Lens Association","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0141703795800433","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
摘要
本研究比较了四种高Dk刚性透气性(RGP)材料(Aquila, Menicon, Super EX, Quantum 1和Quantum 2)的体内润湿性。研究设计是双蒙面右眼/左眼比较,持续6个月,每天佩戴镜片。它涉及三个实验组,每个实验组在一只眼睛中使用Aquila,在另一只眼睛中使用另一种材料。得到的主要结论如下:四种高Dk材料的体内固有润湿性及其在6个月磨损期间的变化是相似的。这些材料的体内特性与低Dk材料没有什么不同,因此增加Dk不会像一些从业者所怀疑的那样导致润湿性降低。体内润湿性高度依赖于患者,因此在常规实践中对其进行持续监测对于最佳患者管理是必要的。体内润湿性受晶状体磨损的影响;佩戴6个月后,与配药相比,隐形眼镜前部泪膜的稳定性明显降低,表面污染程度增加。计划更换的概念应该扩展到RGP隐形眼镜。6个月,甚至3个月的更换频率对相当数量的患者是有益的。
This study compared the in vivo wettability of four high Dk rigid gas permeable (RGP) materials (Aquila, Menicon, Super EX, Quantum 1 and Quantum 2). The study design was a double-masked right/left eye comparison of 6 months' duration where the lenses were worn on a daily-wear basis. It involved three experimental groups, each using Aquila in one eye and one of the other materials in the fellow eye. The main conclusions obtained are as follows: The in vivo intrinsic wettability, and its alteration during a 6-month period of wear, was similar for all four high Dk materials tested. The in vivo characteristics of these materials were not different from those of lower Dk materials, hence increasing Dk does not result in reduced wettability as suspected by some practitioners. In vivo wettability is highly patient dependent, and so its ongoing monitoring during routine practice is necessary for optimal patient management. In vivo wettability is affected by lens wear; after 6 months' wear the stability of the tear film at the front of the contact lens was significantly reduced and the level of surface contamination increased compared with dispensing. The notion of planned replacement should be extended to RGP contact lenses. Replacement frequencies of 6, or even 3 months would be of benefit for a significant number of patients.