{"title":"辐射热照射下单层玻璃沉降面积的概率模型","authors":"D. Wong, K. Li, M. Spearpoint","doi":"10.3801/iafss.fss.11-444","DOIUrl":null,"url":null,"abstract":"This paper investigates the area of window fallout behaviour of 4 mm and 6 mm thick single glazed ordinary float type glass exposed to a constant radiant heat. Regular rubber beadings and non-standard ceramic fibre beadings were used to mount the 525 mm square glass samples in commercial aluminium window frames. A total of 117 experiments were carried out where the area of glass fallout was recorded as a function of time. The average heat fluxes which the glass samples were exposed to ranged from 13 kW/m 2 to 58 kW/m 2 . The lowest heat flux that is needed for fallout occurrence is found to be 20 kW/m 2 for 4 mm thick glass and 28 kW/m 2 for 6 mm thick glass. The fallout behaviour of glass was quantified with an exponential distribution function and a probabilistic area of glass fallout prediction model for 4 mm and 6 mm thick glass is developed from the experimental results.","PeriodicalId":12145,"journal":{"name":"Fire Safety Science","volume":"78 1","pages":"444-457"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"A Probabilistic Model for the Fallout Area of Single Glazing under Radiant Heat Exposure\",\"authors\":\"D. Wong, K. Li, M. Spearpoint\",\"doi\":\"10.3801/iafss.fss.11-444\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper investigates the area of window fallout behaviour of 4 mm and 6 mm thick single glazed ordinary float type glass exposed to a constant radiant heat. Regular rubber beadings and non-standard ceramic fibre beadings were used to mount the 525 mm square glass samples in commercial aluminium window frames. A total of 117 experiments were carried out where the area of glass fallout was recorded as a function of time. The average heat fluxes which the glass samples were exposed to ranged from 13 kW/m 2 to 58 kW/m 2 . The lowest heat flux that is needed for fallout occurrence is found to be 20 kW/m 2 for 4 mm thick glass and 28 kW/m 2 for 6 mm thick glass. The fallout behaviour of glass was quantified with an exponential distribution function and a probabilistic area of glass fallout prediction model for 4 mm and 6 mm thick glass is developed from the experimental results.\",\"PeriodicalId\":12145,\"journal\":{\"name\":\"Fire Safety Science\",\"volume\":\"78 1\",\"pages\":\"444-457\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fire Safety Science\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.3801/iafss.fss.11-444\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Safety Science","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.3801/iafss.fss.11-444","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Probabilistic Model for the Fallout Area of Single Glazing under Radiant Heat Exposure
This paper investigates the area of window fallout behaviour of 4 mm and 6 mm thick single glazed ordinary float type glass exposed to a constant radiant heat. Regular rubber beadings and non-standard ceramic fibre beadings were used to mount the 525 mm square glass samples in commercial aluminium window frames. A total of 117 experiments were carried out where the area of glass fallout was recorded as a function of time. The average heat fluxes which the glass samples were exposed to ranged from 13 kW/m 2 to 58 kW/m 2 . The lowest heat flux that is needed for fallout occurrence is found to be 20 kW/m 2 for 4 mm thick glass and 28 kW/m 2 for 6 mm thick glass. The fallout behaviour of glass was quantified with an exponential distribution function and a probabilistic area of glass fallout prediction model for 4 mm and 6 mm thick glass is developed from the experimental results.