{"title":"AgNO3溶液对碘和有机碘化物去除率的评价","authors":"T. Kanai, M. Furuya, S. Nisimura","doi":"10.3327/taesj.j18.034","DOIUrl":null,"url":null,"abstract":"When excess pressure and temperature are added to a containment vessel of a nuclear power plant during a severe accident, damage of the containment vessel and the release of radioactive materials into the environment are expected. Filtered containment venting systems (FCVS) installed in exhaust systems reduce the release of radioactive materials by the use of multistage filters. In actual FCVS, several types of alkaline solution are used in the scrubbing stage to capture the radioactive iodine (I2). Therefore, it is difficult to remove CH3I by the alkaline solution, and molecular sieves such as silver zeolites installed downstream of the scrubbing stage are used to capture the organic iodide (CH3I). Silver nitrate aqueous solution (AgNO3 aq.) is highly reactive against iodine; hence, by using AgNO3 aq., the removal of organic iodide in the scrubbing stage can be expected. We have conducted basic evaluations of the removal properties of iodine and organic iodide by AgNO3 aq. using smallscale and pool-scrubbing (inner diameter: 300 mm) test sections at ambient temperature and pressure. The small-scale test results show that AgNO3 aq. has the same I2 removal performance as sodium hydroxide aqueous solution (NaOH aq.). Moreover, the pool-scrubbing test results show that a CH3I decontamination factor (DF) of over 50 can be expected under the conditions of a AgNO3 concentration ≥ 10 wt% and submergence ≥ 1.14 m.","PeriodicalId":8595,"journal":{"name":"Atomic Energy Society of Japan","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the Removal Properties of Iodine and Organic Iodide by a AgNO3 Solution\",\"authors\":\"T. Kanai, M. Furuya, S. Nisimura\",\"doi\":\"10.3327/taesj.j18.034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When excess pressure and temperature are added to a containment vessel of a nuclear power plant during a severe accident, damage of the containment vessel and the release of radioactive materials into the environment are expected. Filtered containment venting systems (FCVS) installed in exhaust systems reduce the release of radioactive materials by the use of multistage filters. In actual FCVS, several types of alkaline solution are used in the scrubbing stage to capture the radioactive iodine (I2). Therefore, it is difficult to remove CH3I by the alkaline solution, and molecular sieves such as silver zeolites installed downstream of the scrubbing stage are used to capture the organic iodide (CH3I). Silver nitrate aqueous solution (AgNO3 aq.) is highly reactive against iodine; hence, by using AgNO3 aq., the removal of organic iodide in the scrubbing stage can be expected. We have conducted basic evaluations of the removal properties of iodine and organic iodide by AgNO3 aq. using smallscale and pool-scrubbing (inner diameter: 300 mm) test sections at ambient temperature and pressure. The small-scale test results show that AgNO3 aq. has the same I2 removal performance as sodium hydroxide aqueous solution (NaOH aq.). Moreover, the pool-scrubbing test results show that a CH3I decontamination factor (DF) of over 50 can be expected under the conditions of a AgNO3 concentration ≥ 10 wt% and submergence ≥ 1.14 m.\",\"PeriodicalId\":8595,\"journal\":{\"name\":\"Atomic Energy Society of Japan\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Atomic Energy Society of Japan\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3327/taesj.j18.034\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atomic Energy Society of Japan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3327/taesj.j18.034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在一次严重事故中,当核电站的安全壳增加了过高的压力和温度时,安全壳的损坏和放射性物质释放到环境中是可以预料的。安装在排气系统中的过滤容器排气系统(FCVS)通过使用多级过滤器减少放射性物质的释放。在实际的FCVS中,在洗涤阶段使用几种碱性溶液来捕获放射性碘(I2)。因此,碱性溶液很难去除CH3I,因此采用安装在洗涤阶段下游的银沸石等分子筛来捕获有机碘化物(CH3I)。硝酸银水溶液(agno3aq .)对碘具有高活性;因此,通过使用agno3aq,可以期望在洗涤阶段去除有机碘化物。在常温常压下,采用小型池擦洗(内径300 mm)试样,对AgNO3水溶液去除碘和有机碘的性能进行了基本评价。小试结果表明,AgNO3水溶液与NaOH水溶液具有相同的I2去除率。洗涤池试验结果表明,当AgNO3浓度≥10 wt%,沉水≥1.14 m时,CH3I去污系数(DF)可达50以上。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of the Removal Properties of Iodine and Organic Iodide by a AgNO3 Solution
When excess pressure and temperature are added to a containment vessel of a nuclear power plant during a severe accident, damage of the containment vessel and the release of radioactive materials into the environment are expected. Filtered containment venting systems (FCVS) installed in exhaust systems reduce the release of radioactive materials by the use of multistage filters. In actual FCVS, several types of alkaline solution are used in the scrubbing stage to capture the radioactive iodine (I2). Therefore, it is difficult to remove CH3I by the alkaline solution, and molecular sieves such as silver zeolites installed downstream of the scrubbing stage are used to capture the organic iodide (CH3I). Silver nitrate aqueous solution (AgNO3 aq.) is highly reactive against iodine; hence, by using AgNO3 aq., the removal of organic iodide in the scrubbing stage can be expected. We have conducted basic evaluations of the removal properties of iodine and organic iodide by AgNO3 aq. using smallscale and pool-scrubbing (inner diameter: 300 mm) test sections at ambient temperature and pressure. The small-scale test results show that AgNO3 aq. has the same I2 removal performance as sodium hydroxide aqueous solution (NaOH aq.). Moreover, the pool-scrubbing test results show that a CH3I decontamination factor (DF) of over 50 can be expected under the conditions of a AgNO3 concentration ≥ 10 wt% and submergence ≥ 1.14 m.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development and application of the neutron standards Statement of the AESJ Ethics Committee on the incident of receipt of cash-and-gifts committed by KEPCO Research and Development of Processing and Disposal of Solid Radioactive Waste R&D Activities on Decommissioning of Fukushima Daiichi Nuclear Power Station Locally mesh-refined lattice Boltzmann method for fuel debris air cooling analysis on GPU supercomputer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1