D. A. Glukhov, E. Khakimzyanov, D. Y. Titov, G. G. Ugarov, R. Mustafin
{"title":"用同步矢量测量数据评价传输线跨秒电导率的线性绝缘失效风险分析","authors":"D. A. Glukhov, E. Khakimzyanov, D. Y. Titov, G. G. Ugarov, R. Mustafin","doi":"10.30724/1998-9903-2018-20-11-12-34-45","DOIUrl":null,"url":null,"abstract":"In the article the method of an estimation of a condition of isolation of overhead transmission lines with use of the data of the synchronized vector measurements is offered, the justification of necessary diagnostic parameters is resulted.","PeriodicalId":33495,"journal":{"name":"Izvestiia vysshikh uchebnykh zavedenii Problemy energetiki","volume":"82 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ANALYSIS OF RISK OF FAILURE OF LINEAR INSULATION BY EVALUATING THE CROSS-SECOND CONDUCTIVITY OF TRANSMISSIONS LINES BY DATA OF SYNCHRONIZED VECTOR MEASUREMENTS\",\"authors\":\"D. A. Glukhov, E. Khakimzyanov, D. Y. Titov, G. G. Ugarov, R. Mustafin\",\"doi\":\"10.30724/1998-9903-2018-20-11-12-34-45\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the article the method of an estimation of a condition of isolation of overhead transmission lines with use of the data of the synchronized vector measurements is offered, the justification of necessary diagnostic parameters is resulted.\",\"PeriodicalId\":33495,\"journal\":{\"name\":\"Izvestiia vysshikh uchebnykh zavedenii Problemy energetiki\",\"volume\":\"82 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-02-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Izvestiia vysshikh uchebnykh zavedenii Problemy energetiki\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30724/1998-9903-2018-20-11-12-34-45\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Izvestiia vysshikh uchebnykh zavedenii Problemy energetiki","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30724/1998-9903-2018-20-11-12-34-45","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
ANALYSIS OF RISK OF FAILURE OF LINEAR INSULATION BY EVALUATING THE CROSS-SECOND CONDUCTIVITY OF TRANSMISSIONS LINES BY DATA OF SYNCHRONIZED VECTOR MEASUREMENTS
In the article the method of an estimation of a condition of isolation of overhead transmission lines with use of the data of the synchronized vector measurements is offered, the justification of necessary diagnostic parameters is resulted.