利用闭路电视和探地雷达监测结果分析污水管道缺陷及地面沉降风险

IF 0.4 Q4 ENGINEERING, GEOLOGICAL Journal of the Korean Geosynthetic Society Pub Date : 2018-01-01 DOI:10.12814/JKGSS.2018.17.3.047
D. Lee
{"title":"利用闭路电视和探地雷达监测结果分析污水管道缺陷及地面沉降风险","authors":"D. Lee","doi":"10.12814/JKGSS.2018.17.3.047","DOIUrl":null,"url":null,"abstract":"Recently, increasing number of urban ground subsidence occurrences has been identified. This situation is mainly due to the increased number of underground cavities. This study is intended to develop the method that prevents ground settlement caused by deteriorated or damaged sewers, which are the main cause of land subsidence. To that end, GPR exploration was conducted using CCTV monitoring of deteriorated sewer at the location with high settlement potential. Through such CCTV monitoring and GPR investigation, abnormal ground behavior was monitored at the site where sewer was damaged, joint was cracked and soil was deposited. According to site investigation in this study, evaluation method using correlation analysis of CCTV monitoring and GPR investigation results is expected to prevent ground settlement attributable to damaged sewer.","PeriodicalId":42164,"journal":{"name":"Journal of the Korean Geosynthetic Society","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Analysis of Sewer Pipe Defect and Ground Subsidence Risk by Using CCTV and GPR Monitering Results\",\"authors\":\"D. Lee\",\"doi\":\"10.12814/JKGSS.2018.17.3.047\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, increasing number of urban ground subsidence occurrences has been identified. This situation is mainly due to the increased number of underground cavities. This study is intended to develop the method that prevents ground settlement caused by deteriorated or damaged sewers, which are the main cause of land subsidence. To that end, GPR exploration was conducted using CCTV monitoring of deteriorated sewer at the location with high settlement potential. Through such CCTV monitoring and GPR investigation, abnormal ground behavior was monitored at the site where sewer was damaged, joint was cracked and soil was deposited. According to site investigation in this study, evaluation method using correlation analysis of CCTV monitoring and GPR investigation results is expected to prevent ground settlement attributable to damaged sewer.\",\"PeriodicalId\":42164,\"journal\":{\"name\":\"Journal of the Korean Geosynthetic Society\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Korean Geosynthetic Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12814/JKGSS.2018.17.3.047\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, GEOLOGICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Korean Geosynthetic Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12814/JKGSS.2018.17.3.047","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, GEOLOGICAL","Score":null,"Total":0}
引用次数: 4

摘要

近年来,人们发现越来越多的城市地面沉降事件。这种情况主要是由于地下洞室数量的增加。本研究旨在发展防止因下水道恶化或损坏而引起地面沉降的方法,这是地面沉降的主要原因。为此,在沉降潜力较大的地段,利用闭路电视监测劣化下水道进行探地雷达勘探。通过CCTV监控和探地雷达调查,在下水道损坏、接缝开裂、积土的现场,监测到异常的地面行为。根据本研究的现场调查,利用闭路电视监控和探地雷达调查结果的相关性分析的评价方法,有望防止因下水道损坏引起的地面沉降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of Sewer Pipe Defect and Ground Subsidence Risk by Using CCTV and GPR Monitering Results
Recently, increasing number of urban ground subsidence occurrences has been identified. This situation is mainly due to the increased number of underground cavities. This study is intended to develop the method that prevents ground settlement caused by deteriorated or damaged sewers, which are the main cause of land subsidence. To that end, GPR exploration was conducted using CCTV monitoring of deteriorated sewer at the location with high settlement potential. Through such CCTV monitoring and GPR investigation, abnormal ground behavior was monitored at the site where sewer was damaged, joint was cracked and soil was deposited. According to site investigation in this study, evaluation method using correlation analysis of CCTV monitoring and GPR investigation results is expected to prevent ground settlement attributable to damaged sewer.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
20.00%
发文量
0
期刊最新文献
Evaluation of Field Applicability of Slope of Improved Soil for Ground Stabilizer Analysis of the Correlation between the velocity speed of High-Speed Railways and the Suppressing Effect of lateral Displacement of retaining wall according to the Arrangement of Stabilizing Piles Behavioral Characteristics and Safety Management Plan for Fill Dam During Water Level Fluctuation Using Numerical Analysis Application of Laboratory Pressurized Vane Shear Test and Discrete Element Method for Determination of Foam-conditioned Soil Properties Development and Reliability Verification of Quality Control System for Compaction Grouting Method
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1