基于atmega328p - pu单片机的低成本智能能源管理

M. Caruso, V. Castiglia, A. Del Pizzo, R. Miceli, M. Salles, G. Schettino, V. Traversa, F. Viola
{"title":"基于atmega328p - pu单片机的低成本智能能源管理","authors":"M. Caruso, V. Castiglia, A. Del Pizzo, R. Miceli, M. Salles, G. Schettino, V. Traversa, F. Viola","doi":"10.1109/DISTRA.2017.8191244","DOIUrl":null,"url":null,"abstract":"This paper presents a real-time, low-cost, wireless, AC and DC monitoring system based on an ATmega328P-PU microcontroller. The proposed system is composed by different client nodes, which have the task to measure the main electrical quantities involved in the system, and a server node that collects the data and send them to a display device. The system is well suited for a good accuracy monitoring of either AC or DC electrical quantities. In order to verify the correct operation of the system, a case study for the simultaneous monitoring of the DC and AC voltages and currents is provided.","PeriodicalId":6535,"journal":{"name":"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"37 1","pages":"1204-1209"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Low-cost smart energy managment based on ATmega 328P-PU microcontroller\",\"authors\":\"M. Caruso, V. Castiglia, A. Del Pizzo, R. Miceli, M. Salles, G. Schettino, V. Traversa, F. Viola\",\"doi\":\"10.1109/DISTRA.2017.8191244\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a real-time, low-cost, wireless, AC and DC monitoring system based on an ATmega328P-PU microcontroller. The proposed system is composed by different client nodes, which have the task to measure the main electrical quantities involved in the system, and a server node that collects the data and send them to a display device. The system is well suited for a good accuracy monitoring of either AC or DC electrical quantities. In order to verify the correct operation of the system, a case study for the simultaneous monitoring of the DC and AC voltages and currents is provided.\",\"PeriodicalId\":6535,\"journal\":{\"name\":\"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)\",\"volume\":\"37 1\",\"pages\":\"1204-1209\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DISTRA.2017.8191244\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DISTRA.2017.8191244","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

本文介绍了一种基于ATmega328P-PU单片机的实时、低成本、无线、交直流监控系统。该系统由不同的客户端节点和服务器节点组成,客户端节点的任务是测量系统中涉及的主要电量,服务器节点负责收集数据并将其发送到显示设备。该系统非常适合于交流或直流电量的高精度监测。为了验证系统的正确运行,给出了一个同时监测直流和交流电压和电流的案例研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Low-cost smart energy managment based on ATmega 328P-PU microcontroller
This paper presents a real-time, low-cost, wireless, AC and DC monitoring system based on an ATmega328P-PU microcontroller. The proposed system is composed by different client nodes, which have the task to measure the main electrical quantities involved in the system, and a server node that collects the data and send them to a display device. The system is well suited for a good accuracy monitoring of either AC or DC electrical quantities. In order to verify the correct operation of the system, a case study for the simultaneous monitoring of the DC and AC voltages and currents is provided.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of AC link topologies in non-isolated DC/DC triple active bridge converter for current stress minimization Modelling and attitude control of a shrouded floating offshore wind turbine with hinged structure in extreme conditions Direct load control of air conditioners in Qatar: An empirical study Stochastic unit commitment considering Markov process of wind power forecast Primary and secondary voltage/frequency controller design for energy storage devices using consensus theory
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1