{"title":"利用深度相关不匹配滤波提高医学超声成像的分辨率和动态范围","authors":"A. R. Brenner, K. Eck, W. Wilhelm, T. Noll","doi":"10.1109/ULTSYM.1997.661855","DOIUrl":null,"url":null,"abstract":"The authors present a depth-dependent mismatched-filter pulse compression technique which improves range resolution and dynamic range of coded excitation ultrasonic imaging compared to a matched-filter pulse compression. After choosing a suitable magnitude spectrum, frequency weighting is used to design the appropriate mismatched filter depth-dependently, which allows to control mainlobe width and sidelobe characteristics. Both simulations and measurements are used to demonstrate the efficacy of the technique. A VLSI implementation of a depth-dependent mismatched filter is shown to be feasible.","PeriodicalId":6369,"journal":{"name":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","volume":"58 1","pages":"1475-1480 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Improved resolution and dynamic range in medical ultrasonic imaging using depth-dependent mismatched filtering\",\"authors\":\"A. R. Brenner, K. Eck, W. Wilhelm, T. Noll\",\"doi\":\"10.1109/ULTSYM.1997.661855\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors present a depth-dependent mismatched-filter pulse compression technique which improves range resolution and dynamic range of coded excitation ultrasonic imaging compared to a matched-filter pulse compression. After choosing a suitable magnitude spectrum, frequency weighting is used to design the appropriate mismatched filter depth-dependently, which allows to control mainlobe width and sidelobe characteristics. Both simulations and measurements are used to demonstrate the efficacy of the technique. A VLSI implementation of a depth-dependent mismatched filter is shown to be feasible.\",\"PeriodicalId\":6369,\"journal\":{\"name\":\"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)\",\"volume\":\"58 1\",\"pages\":\"1475-1480 vol.2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1997.661855\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1997.661855","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Improved resolution and dynamic range in medical ultrasonic imaging using depth-dependent mismatched filtering
The authors present a depth-dependent mismatched-filter pulse compression technique which improves range resolution and dynamic range of coded excitation ultrasonic imaging compared to a matched-filter pulse compression. After choosing a suitable magnitude spectrum, frequency weighting is used to design the appropriate mismatched filter depth-dependently, which allows to control mainlobe width and sidelobe characteristics. Both simulations and measurements are used to demonstrate the efficacy of the technique. A VLSI implementation of a depth-dependent mismatched filter is shown to be feasible.