N. Okada, K. Higuchi, K. Kobayashi, M. Ito, M. Takabe, M. Otonari, D. Akai, K. Sawada, M. Ishida
{"title":"基于外延γ - al2o3 /Si衬底生长的PZT薄膜的二维水听器阵列系统的P1J-3评价","authors":"N. Okada, K. Higuchi, K. Kobayashi, M. Ito, M. Takabe, M. Otonari, D. Akai, K. Sawada, M. Ishida","doi":"10.1109/ULTSYM.2007.366","DOIUrl":null,"url":null,"abstract":"A piezoelectric ultrasonic hydrophone array was fabricated using epitaxial lead zirconate titanate, Pb(Zx, Ti1-x)O3 (PZT) thin film grown on epitaxial SrRuO3/Pt/gamma-Al2O3/Si substrates. PZT film with 3 mum in thickness was prepared by sol- gel method. An experimental ultrasonic hydrophone array measurement system, a one dimensional (1-D) array of 10 elements and a two dimensional (2D) array of 4 times 4 elements have been developed to evaluate the hydrophone array system performance. In this paper, we describe the fabrication process of the hydrophone arrays and the data acquisition system. The beam direction was estimated and the B-mode image was reconstructed to evaluate the array sensitivity. The potential applications for this hydrophone array are discussed.","PeriodicalId":6355,"journal":{"name":"2007 IEEE Ultrasonics Symposium Proceedings","volume":"29 1","pages":"1456-1459"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"P1J-3 Evaluation of 2D Hydrophone Array System Using Epitaxial PZT Thin Film Grown on Epitaxial GAMMA-Al2O3/Si Substrate\",\"authors\":\"N. Okada, K. Higuchi, K. Kobayashi, M. Ito, M. Takabe, M. Otonari, D. Akai, K. Sawada, M. Ishida\",\"doi\":\"10.1109/ULTSYM.2007.366\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A piezoelectric ultrasonic hydrophone array was fabricated using epitaxial lead zirconate titanate, Pb(Zx, Ti1-x)O3 (PZT) thin film grown on epitaxial SrRuO3/Pt/gamma-Al2O3/Si substrates. PZT film with 3 mum in thickness was prepared by sol- gel method. An experimental ultrasonic hydrophone array measurement system, a one dimensional (1-D) array of 10 elements and a two dimensional (2D) array of 4 times 4 elements have been developed to evaluate the hydrophone array system performance. In this paper, we describe the fabrication process of the hydrophone arrays and the data acquisition system. The beam direction was estimated and the B-mode image was reconstructed to evaluate the array sensitivity. The potential applications for this hydrophone array are discussed.\",\"PeriodicalId\":6355,\"journal\":{\"name\":\"2007 IEEE Ultrasonics Symposium Proceedings\",\"volume\":\"29 1\",\"pages\":\"1456-1459\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Ultrasonics Symposium Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2007.366\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Ultrasonics Symposium Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2007.366","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
P1J-3 Evaluation of 2D Hydrophone Array System Using Epitaxial PZT Thin Film Grown on Epitaxial GAMMA-Al2O3/Si Substrate
A piezoelectric ultrasonic hydrophone array was fabricated using epitaxial lead zirconate titanate, Pb(Zx, Ti1-x)O3 (PZT) thin film grown on epitaxial SrRuO3/Pt/gamma-Al2O3/Si substrates. PZT film with 3 mum in thickness was prepared by sol- gel method. An experimental ultrasonic hydrophone array measurement system, a one dimensional (1-D) array of 10 elements and a two dimensional (2D) array of 4 times 4 elements have been developed to evaluate the hydrophone array system performance. In this paper, we describe the fabrication process of the hydrophone arrays and the data acquisition system. The beam direction was estimated and the B-mode image was reconstructed to evaluate the array sensitivity. The potential applications for this hydrophone array are discussed.