Daria Wróbel , Agnieszka Skrobała , Tomasz Piotrowski
{"title":"Analiza wyników weryfikacji geometrycznej obrazów megawoltowych u pacjentek napromienianych w obszarze lewego gruczołu piersiowego","authors":"Daria Wróbel ,&nbsp;Agnieszka Skrobała ,&nbsp;Tomasz Piotrowski","doi":"10.1016/j.onko.2014.09.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Aim</h3><p>The aim of this study was to analyze the influence of the size of the clinical target volume (CTV) on the displacement obtained from the patients irradiated because of the left breast cancer using the geometric verification with the megavoltage images.</p></div><div><h3>Material and method</h3><p>Examined group of 100 patients was treated with the three-dimensional conformal radiotherapy. The analysis was performed on the 396 megavoltage images. The examined group of patients was divided into two subgroups according to the breast's CTV volume. The first subgroup (I) was the patient with the CTV<!--> <!-->≤<!--> <!-->700 cm<sup>3</sup> and the second (II) one CTV<!--> <!-->&gt;<!--> <!-->700 cm<sup>3</sup>. The displacements were obtained in the three directions: anterior-posterior (AP), crania-caudal (CC) and left-right (LR). The systematic (Σ), random (σ) errors and safety margins (SM) were calculated.</p></div><div><h3>Results</h3><p>The range of the Σ error was 0,20–0,34<!--> <!-->cm for the (I) and 0,26–0,42<!--> <!-->cm for the (II). The maximum value of the σ error was 0,46–0,26<!--> <!-->cm, respectively. The lowest value of the SM was in the AP and the largest one in the CC direction. The SM ranges were 0,65–1,00<!--> <!-->cm for CTV<!--> <!-->≤<!--> <!-->700 cm<sup>3</sup> and 0,88–1,37<!--> <!-->cm for CTV<!--> <!-->&gt;<!--> <!-->700 cm<sup>3</sup>. SM for the whole group of the breast patient was in the range 0,80–1,24<!--> <!-->cm.</p></div><div><h3>Conclusions</h3><p>The set-up of the breast patient with the smaller volume of the CTV<!--> <!-->≤<!--> <!-->700 cm<sup>3</sup> is much accurate and connected with smaller values of the geometric displacements. Safety margin used during the treatment planning should be selected individually depending on the size of the breast volume – CTV.</p></div>","PeriodicalId":101295,"journal":{"name":"Zeszyty Naukowe WCO, Letters in Oncology Science","volume":"11 3","pages":"Pages 53-60"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.onko.2014.09.003","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeszyty Naukowe WCO, Letters in Oncology Science","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1734048914000248","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的应用巨压图像的几何验证方法,分析临床靶体积(CTV)大小对左乳腺癌放疗患者位移的影响。材料与方法观察组100例患者行三维适形放射治疗。对396张兆压图像进行了分析。根据乳腺CTV体积将检查组患者分为两个亚组。第一亚组(I)为CTV≤700 cm3的患者,第二亚组(II)为CTV≤700 cm3的患者;700立方厘米。在前后(AP)、颅尾(CC)和左右(LR)三个方向上获得位移。计算了系统误差(Σ)、随机误差(Σ)和安全裕度(SM)。结果(1)和(2)的Σ误差范围分别为0、20 ~ 0、34 cm和0、26 ~ 0、42 cm, Σ误差最大值分别为0、46 ~ 0、26 cm。SM在AP方向最小,在CC方向最大。CTV≤700 cm3的SM范围为0.65 ~ 0.00 cm, CTV >的SM范围为0.88 ~ 1.37 cm;700立方厘米。全组乳腺患者的SM范围为0,80 - 1,24 cm。结论CTV体积较小≤700 cm3的乳腺患者的设置精度较高,且与较小的几何位移值相关。治疗计划中使用的安全裕度应根据乳房体积(CTV)的大小单独选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analiza wyników weryfikacji geometrycznej obrazów megawoltowych u pacjentek napromienianych w obszarze lewego gruczołu piersiowego

Aim

The aim of this study was to analyze the influence of the size of the clinical target volume (CTV) on the displacement obtained from the patients irradiated because of the left breast cancer using the geometric verification with the megavoltage images.

Material and method

Examined group of 100 patients was treated with the three-dimensional conformal radiotherapy. The analysis was performed on the 396 megavoltage images. The examined group of patients was divided into two subgroups according to the breast's CTV volume. The first subgroup (I) was the patient with the CTV  700 cm3 and the second (II) one CTV > 700 cm3. The displacements were obtained in the three directions: anterior-posterior (AP), crania-caudal (CC) and left-right (LR). The systematic (Σ), random (σ) errors and safety margins (SM) were calculated.

Results

The range of the Σ error was 0,20–0,34 cm for the (I) and 0,26–0,42 cm for the (II). The maximum value of the σ error was 0,46–0,26 cm, respectively. The lowest value of the SM was in the AP and the largest one in the CC direction. The SM ranges were 0,65–1,00 cm for CTV  700 cm3 and 0,88–1,37 cm for CTV > 700 cm3. SM for the whole group of the breast patient was in the range 0,80–1,24 cm.

Conclusions

The set-up of the breast patient with the smaller volume of the CTV  700 cm3 is much accurate and connected with smaller values of the geometric displacements. Safety margin used during the treatment planning should be selected individually depending on the size of the breast volume – CTV.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Editorial Board Radioterapia w leczeniu raka sromu Co nowego w leczeniu napromienianiem raka stercza oraz raka pęcherza moczowego na podstawie doniesień z Konferencji Amerykańskiego Towarzystwa Radioterapii Onkologicznej (ASTRO), San Francisco 2014? Rola SIB-IMRT w radioterapii przerzutów do mózgu – doniesienie konferencyjne z ESTRO Forum 2015 Sprawozdanie z pobytu na 56. konferencji ASTRO
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1