{"title":"基于三相四线DSTATCOM装置的带接口电感组脉冲发生器的自适应区间模糊控制器","authors":"Muhannad Drak Alsebai, Kamala Narayanan, Kishore Kumar Pedapenki","doi":"10.3311/ppee.20890","DOIUrl":null,"url":null,"abstract":"It goes without saying that the electrical distribution system is facing many power-quality issues these days. The main cause of these issues is the wide spread of nonlinear load integrated with the electrical distribution system. Moreover, the DSTATCOM device with interface inductor has different control algorithms. These encompass proportional integral controller, Interval type I fuzzy logic and interval type II fuzzy logic along used for improving the power quality issues. Before integration with the electrical distribution grid, these controllers need the tune processing. The combination of DSTATCOM with the load, which is different from the tuned one, and the wrong selection of the interface inductor leads to the failure of DSTATCOM device in the mitigation of source current harmonics. This study suggests that the use of adaptive interval type II fuzzy logic with the interface bank pulse generator based DSTATCOM device with self-tunning process and self-selection of the interface inductor would be suitable for all load types integrated into the distribution system within the rated power of DSTATCOM device. The adaptive interval type II fuzzy logic with the interface bank pulse generator based DSTATCOM device mitigates the source current harmonics and gives fast DC capacitor bus voltage response. Employing the suggested control algorithm based DSATCOM device makes the DC capacitor voltage signal settling time at almost 50 ms and total harmonic distortion of the source current at almost 4% for all cases of the load connected with the distribution system within the rated power of DSTATCOM device.","PeriodicalId":37664,"journal":{"name":"Periodica polytechnica Electrical engineering and computer science","volume":"30 1","pages":"113-135"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Adaptive Interval Type II Fuzzy Logic Controller with Interface Inductor Bank Pulse Generator Based Three-Phase Four-Wire DSTATCOM Device for Power Quality Improvement\",\"authors\":\"Muhannad Drak Alsebai, Kamala Narayanan, Kishore Kumar Pedapenki\",\"doi\":\"10.3311/ppee.20890\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It goes without saying that the electrical distribution system is facing many power-quality issues these days. The main cause of these issues is the wide spread of nonlinear load integrated with the electrical distribution system. Moreover, the DSTATCOM device with interface inductor has different control algorithms. These encompass proportional integral controller, Interval type I fuzzy logic and interval type II fuzzy logic along used for improving the power quality issues. Before integration with the electrical distribution grid, these controllers need the tune processing. The combination of DSTATCOM with the load, which is different from the tuned one, and the wrong selection of the interface inductor leads to the failure of DSTATCOM device in the mitigation of source current harmonics. This study suggests that the use of adaptive interval type II fuzzy logic with the interface bank pulse generator based DSTATCOM device with self-tunning process and self-selection of the interface inductor would be suitable for all load types integrated into the distribution system within the rated power of DSTATCOM device. The adaptive interval type II fuzzy logic with the interface bank pulse generator based DSTATCOM device mitigates the source current harmonics and gives fast DC capacitor bus voltage response. Employing the suggested control algorithm based DSATCOM device makes the DC capacitor voltage signal settling time at almost 50 ms and total harmonic distortion of the source current at almost 4% for all cases of the load connected with the distribution system within the rated power of DSTATCOM device.\",\"PeriodicalId\":37664,\"journal\":{\"name\":\"Periodica polytechnica Electrical engineering and computer science\",\"volume\":\"30 1\",\"pages\":\"113-135\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Periodica polytechnica Electrical engineering and computer science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3311/ppee.20890\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Computer Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Periodica polytechnica Electrical engineering and computer science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3311/ppee.20890","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Computer Science","Score":null,"Total":0}
Adaptive Interval Type II Fuzzy Logic Controller with Interface Inductor Bank Pulse Generator Based Three-Phase Four-Wire DSTATCOM Device for Power Quality Improvement
It goes without saying that the electrical distribution system is facing many power-quality issues these days. The main cause of these issues is the wide spread of nonlinear load integrated with the electrical distribution system. Moreover, the DSTATCOM device with interface inductor has different control algorithms. These encompass proportional integral controller, Interval type I fuzzy logic and interval type II fuzzy logic along used for improving the power quality issues. Before integration with the electrical distribution grid, these controllers need the tune processing. The combination of DSTATCOM with the load, which is different from the tuned one, and the wrong selection of the interface inductor leads to the failure of DSTATCOM device in the mitigation of source current harmonics. This study suggests that the use of adaptive interval type II fuzzy logic with the interface bank pulse generator based DSTATCOM device with self-tunning process and self-selection of the interface inductor would be suitable for all load types integrated into the distribution system within the rated power of DSTATCOM device. The adaptive interval type II fuzzy logic with the interface bank pulse generator based DSTATCOM device mitigates the source current harmonics and gives fast DC capacitor bus voltage response. Employing the suggested control algorithm based DSATCOM device makes the DC capacitor voltage signal settling time at almost 50 ms and total harmonic distortion of the source current at almost 4% for all cases of the load connected with the distribution system within the rated power of DSTATCOM device.
期刊介绍:
The main scope of the journal is to publish original research articles in the wide field of electrical engineering and informatics fitting into one of the following five Sections of the Journal: (i) Communication systems, networks and technology, (ii) Computer science and information theory, (iii) Control, signal processing and signal analysis, medical applications, (iv) Components, Microelectronics and Material Sciences, (v) Power engineering and mechatronics, (vi) Mobile Software, Internet of Things and Wearable Devices, (vii) Solid-state lighting and (viii) Vehicular Technology (land, airborne, and maritime mobile services; automotive, radar systems; antennas and radio wave propagation).